Effects of pre-storage leukoreduction on erythrocyte concentrates and performance of newer generation leuko-filters at a tertiary care oncology hospital in Western India

Background: Leukoreduction is a post-processing technique that reduces residual leukocytes in cellular blood components. Previous studies have evaluated these parameters mainly among older generation leuko-filters. Objective: This study evaluated the immediate effects of pre-storage leukoreduction...

Full description

Saved in:
Bibliographic Details
Main Authors: Deep Madkaiker, Shashank Ojha, Arunkumar N., Kalpesh Chawan
Format: Article
Language:English
Published: AOSIS 2025-06-01
Series:African Journal of Laboratory Medicine
Subjects:
Online Access:https://ajlmonline.org/index.php/ajlm/article/view/2723
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850093110579691520
author Deep Madkaiker
Shashank Ojha
Arunkumar N.
Kalpesh Chawan
author_facet Deep Madkaiker
Shashank Ojha
Arunkumar N.
Kalpesh Chawan
author_sort Deep Madkaiker
collection DOAJ
description Background: Leukoreduction is a post-processing technique that reduces residual leukocytes in cellular blood components. Previous studies have evaluated these parameters mainly among older generation leuko-filters. Objective: This study evaluated the immediate effects of pre-storage leukoreduction on red cell indices and the performance efficacy of two newer generation leuko-filters. Methods: This retrospective analysis collected quality control data before and after leukoreduction for erythrocyte concentrates (ECs) from laboratory registers from the Blood Transfusion Laboratory at the Advanced Centre for Treatment, Research and Education in Cancer in Mumbai, India, for the period January 2015 to December 2019. Data related to red cell indices and performance characteristics for Fresenius and Macopharma filters were included. Results: A total of 500 records was included in the study. All EC units demonstrated a 99.99% leukocyte log reduction, with both filters showing equal efficacy. Post-leukoreduction haemoglobin concentrations were lower than the pre-leukoreduction for all units (p  0.001). Of those prepared from 350 mL units, 11.6% (28/240) had haemoglobin levels under 40 g/bag as compared to 1.1% (3/260) among those prepared from 450 mL units. All indices exhibited statistically significant changes after leukoreduction (p  0.001) except for mean corpuscular haemoglobin (p = 0.215). The Fresenius filter required less time for leukoreduction compared to the Macopharma filter (p  0.001). Conclusion: Red cell indices show several changes following leukoreduction. Further studies are needed to assess the microscopic and functional impact of leukoreduction. Leuko-filters vary in their performance characteristics, which may influence vendor selection. What this study adds: This study found changes among several red cell indices after leukoreduction of ECs, which have not been extensively studied in previous literature. Further, we found that the newer generation leuko-filters differ in specific performance characteristics, which may influence vendor selection.
format Article
id doaj-art-c11b6dace8b249cd864f40f8419fe8b0
institution DOAJ
issn 2225-2002
2225-2010
language English
publishDate 2025-06-01
publisher AOSIS
record_format Article
series African Journal of Laboratory Medicine
spelling doaj-art-c11b6dace8b249cd864f40f8419fe8b02025-08-20T02:41:59ZengAOSISAfrican Journal of Laboratory Medicine2225-20022225-20102025-06-01141e1e710.4102/ajlm.v14i1.2723504Effects of pre-storage leukoreduction on erythrocyte concentrates and performance of newer generation leuko-filters at a tertiary care oncology hospital in Western IndiaDeep Madkaiker0Shashank Ojha1Arunkumar N.2Kalpesh Chawan3Department of Transfusion Medicine, Advanced Centre for Treatment, Research and Education in Cancer, Tata Memorial Centre, Homi Bhabha National Institute, Mumbai, India; and, Department of Immunohematology and Blood Transfusion, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, KarnatakaDepartment of Transfusion Medicine, Advanced Centre for Treatment, Research and Education in Cancer, Tata Memorial Centre, Homi Bhabha National Institute, MumbaiDepartment of Transfusion Medicine, Advanced Centre for Treatment, Research and Education in Cancer, Tata Memorial Centre, Homi Bhabha National Institute, MumbaiDepartment of Transfusion Medicine, Advanced Centre for Treatment, Research and Education in Cancer, Tata Memorial Centre, Homi Bhabha National Institute, MumbaiBackground: Leukoreduction is a post-processing technique that reduces residual leukocytes in cellular blood components. Previous studies have evaluated these parameters mainly among older generation leuko-filters. Objective: This study evaluated the immediate effects of pre-storage leukoreduction on red cell indices and the performance efficacy of two newer generation leuko-filters. Methods: This retrospective analysis collected quality control data before and after leukoreduction for erythrocyte concentrates (ECs) from laboratory registers from the Blood Transfusion Laboratory at the Advanced Centre for Treatment, Research and Education in Cancer in Mumbai, India, for the period January 2015 to December 2019. Data related to red cell indices and performance characteristics for Fresenius and Macopharma filters were included. Results: A total of 500 records was included in the study. All EC units demonstrated a 99.99% leukocyte log reduction, with both filters showing equal efficacy. Post-leukoreduction haemoglobin concentrations were lower than the pre-leukoreduction for all units (p  0.001). Of those prepared from 350 mL units, 11.6% (28/240) had haemoglobin levels under 40 g/bag as compared to 1.1% (3/260) among those prepared from 450 mL units. All indices exhibited statistically significant changes after leukoreduction (p  0.001) except for mean corpuscular haemoglobin (p = 0.215). The Fresenius filter required less time for leukoreduction compared to the Macopharma filter (p  0.001). Conclusion: Red cell indices show several changes following leukoreduction. Further studies are needed to assess the microscopic and functional impact of leukoreduction. Leuko-filters vary in their performance characteristics, which may influence vendor selection. What this study adds: This study found changes among several red cell indices after leukoreduction of ECs, which have not been extensively studied in previous literature. Further, we found that the newer generation leuko-filters differ in specific performance characteristics, which may influence vendor selection.https://ajlmonline.org/index.php/ajlm/article/view/2723leukoreductionred cell indicesquality controlwhole bloodleuko-filterred cell concentrate.
spellingShingle Deep Madkaiker
Shashank Ojha
Arunkumar N.
Kalpesh Chawan
Effects of pre-storage leukoreduction on erythrocyte concentrates and performance of newer generation leuko-filters at a tertiary care oncology hospital in Western India
African Journal of Laboratory Medicine
leukoreduction
red cell indices
quality control
whole blood
leuko-filter
red cell concentrate.
title Effects of pre-storage leukoreduction on erythrocyte concentrates and performance of newer generation leuko-filters at a tertiary care oncology hospital in Western India
title_full Effects of pre-storage leukoreduction on erythrocyte concentrates and performance of newer generation leuko-filters at a tertiary care oncology hospital in Western India
title_fullStr Effects of pre-storage leukoreduction on erythrocyte concentrates and performance of newer generation leuko-filters at a tertiary care oncology hospital in Western India
title_full_unstemmed Effects of pre-storage leukoreduction on erythrocyte concentrates and performance of newer generation leuko-filters at a tertiary care oncology hospital in Western India
title_short Effects of pre-storage leukoreduction on erythrocyte concentrates and performance of newer generation leuko-filters at a tertiary care oncology hospital in Western India
title_sort effects of pre storage leukoreduction on erythrocyte concentrates and performance of newer generation leuko filters at a tertiary care oncology hospital in western india
topic leukoreduction
red cell indices
quality control
whole blood
leuko-filter
red cell concentrate.
url https://ajlmonline.org/index.php/ajlm/article/view/2723
work_keys_str_mv AT deepmadkaiker effectsofprestorageleukoreductiononerythrocyteconcentratesandperformanceofnewergenerationleukofiltersatatertiarycareoncologyhospitalinwesternindia
AT shashankojha effectsofprestorageleukoreductiononerythrocyteconcentratesandperformanceofnewergenerationleukofiltersatatertiarycareoncologyhospitalinwesternindia
AT arunkumarn effectsofprestorageleukoreductiononerythrocyteconcentratesandperformanceofnewergenerationleukofiltersatatertiarycareoncologyhospitalinwesternindia
AT kalpeshchawan effectsofprestorageleukoreductiononerythrocyteconcentratesandperformanceofnewergenerationleukofiltersatatertiarycareoncologyhospitalinwesternindia