The large, viscous thrombus is aspirated by using the cyclic suction technique

With the development of socio-economic conditions and changes in people’s lifestyles, particularly the acceleration of population aging and urbanization, unhealthy living habits among residents have become increasingly prominent. Cardiovascular disease (CVD) risk factors have a growing impact on pub...

Full description

Saved in:
Bibliographic Details
Main Authors: Lin Shenqi, Yu Ling, Hong Ruiting, Dong Runcheng, Liu Bohao, Ruan Wencong, Sun Tao, Zhou Dongqing, Zhou Yixuan, Chen Shi
Format: Article
Language:English
Published: EDP Sciences 2025-01-01
Series:BIO Web of Conferences
Online Access:https://www.bio-conferences.org/articles/bioconf/pdf/2025/25/bioconf_icbb2025_03008.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850267880861466624
author Lin Shenqi
Yu Ling
Hong Ruiting
Dong Runcheng
Liu Bohao
Ruan Wencong
Sun Tao
Zhou Dongqing
Zhou Yixuan
Chen Shi
author_facet Lin Shenqi
Yu Ling
Hong Ruiting
Dong Runcheng
Liu Bohao
Ruan Wencong
Sun Tao
Zhou Dongqing
Zhou Yixuan
Chen Shi
author_sort Lin Shenqi
collection DOAJ
description With the development of socio-economic conditions and changes in people’s lifestyles, particularly the acceleration of population aging and urbanization, unhealthy living habits among residents have become increasingly prominent. Cardiovascular disease (CVD) risk factors have a growing impact on public health, and the incidence of CVD continues to rise. Current research focuses mainly on improving the safety and effectiveness of thrombectomy devices and reducing complications during surgical procedures. Additionally, researchers are exploring the application of these devices in specific patient groups, such as those with comorbid conditions. This project introduces an intelligent device based on an MCU (Microcontroller Unit). Starting with the overall hardware system design, it includes the development of the device casing, selection of the MCU, and design of the internal pipeline length according to the pressure tolerance of the human inferior vena cava during thrombectomy. A pressure control valve and a pressure gauge are installed to ensure that the suction pressure remains within a safe range tolerable for the human body throughout the procedure. Pressure sensor data is then used to develop algorithms and control programs, enabling precise control of the opening and closing actions of the positive and negative pressure solenoid valves at specified intervals. By using optimal timing data, the suction tube of the device can generate impacts to break large thrombi while effectively preventing them from escaping to other parts of the vessel during the suction process, ensuring the smooth completion of thrombectomy. Through its unique design and precise operation, this device can more effectively remove thrombi from blood vessels, overcoming the limitations and risks of traditional treatment methods. This technological innovation not only advances the overall technical capabilities of the medical industry but also provides physicians with a more efficient and convenient treatment tool, further improving the quality and efficiency of medical services. Moreover, by rapidly and effectively removing thrombi, this treatment reduces patient hospitalization time and medication use, thereby lowering medical costs. As the technology becomes more widespread and its application more common, the cost of this treatment method is expected to decrease further, providing more patients with an affordable and effective treatment option.
format Article
id doaj-art-c0403bc7344f49f094d5effb866676ea
institution OA Journals
issn 2117-4458
language English
publishDate 2025-01-01
publisher EDP Sciences
record_format Article
series BIO Web of Conferences
spelling doaj-art-c0403bc7344f49f094d5effb866676ea2025-08-20T01:53:36ZengEDP SciencesBIO Web of Conferences2117-44582025-01-011740300810.1051/bioconf/202517403008bioconf_icbb2025_03008The large, viscous thrombus is aspirated by using the cyclic suction techniqueLin Shenqi0Yu Ling1Hong Ruiting2Dong Runcheng3Liu Bohao4Ruan Wencong5Sun Tao6Zhou Dongqing7Zhou Yixuan8Chen Shi9Shanghai Jian Qiao UniversityShanghai Jian Qiao UniversityShanghai Jian Qiao UniversityShanghai Jian Qiao UniversityShanghai Jian Qiao UniversityShanghai Jian Qiao UniversityShanghai Jian Qiao UniversityShanghai Jian Qiao UniversityShanghai Jian Qiao UniversityShanghai Jian Qiao UniversityWith the development of socio-economic conditions and changes in people’s lifestyles, particularly the acceleration of population aging and urbanization, unhealthy living habits among residents have become increasingly prominent. Cardiovascular disease (CVD) risk factors have a growing impact on public health, and the incidence of CVD continues to rise. Current research focuses mainly on improving the safety and effectiveness of thrombectomy devices and reducing complications during surgical procedures. Additionally, researchers are exploring the application of these devices in specific patient groups, such as those with comorbid conditions. This project introduces an intelligent device based on an MCU (Microcontroller Unit). Starting with the overall hardware system design, it includes the development of the device casing, selection of the MCU, and design of the internal pipeline length according to the pressure tolerance of the human inferior vena cava during thrombectomy. A pressure control valve and a pressure gauge are installed to ensure that the suction pressure remains within a safe range tolerable for the human body throughout the procedure. Pressure sensor data is then used to develop algorithms and control programs, enabling precise control of the opening and closing actions of the positive and negative pressure solenoid valves at specified intervals. By using optimal timing data, the suction tube of the device can generate impacts to break large thrombi while effectively preventing them from escaping to other parts of the vessel during the suction process, ensuring the smooth completion of thrombectomy. Through its unique design and precise operation, this device can more effectively remove thrombi from blood vessels, overcoming the limitations and risks of traditional treatment methods. This technological innovation not only advances the overall technical capabilities of the medical industry but also provides physicians with a more efficient and convenient treatment tool, further improving the quality and efficiency of medical services. Moreover, by rapidly and effectively removing thrombi, this treatment reduces patient hospitalization time and medication use, thereby lowering medical costs. As the technology becomes more widespread and its application more common, the cost of this treatment method is expected to decrease further, providing more patients with an affordable and effective treatment option.https://www.bio-conferences.org/articles/bioconf/pdf/2025/25/bioconf_icbb2025_03008.pdf
spellingShingle Lin Shenqi
Yu Ling
Hong Ruiting
Dong Runcheng
Liu Bohao
Ruan Wencong
Sun Tao
Zhou Dongqing
Zhou Yixuan
Chen Shi
The large, viscous thrombus is aspirated by using the cyclic suction technique
BIO Web of Conferences
title The large, viscous thrombus is aspirated by using the cyclic suction technique
title_full The large, viscous thrombus is aspirated by using the cyclic suction technique
title_fullStr The large, viscous thrombus is aspirated by using the cyclic suction technique
title_full_unstemmed The large, viscous thrombus is aspirated by using the cyclic suction technique
title_short The large, viscous thrombus is aspirated by using the cyclic suction technique
title_sort large viscous thrombus is aspirated by using the cyclic suction technique
url https://www.bio-conferences.org/articles/bioconf/pdf/2025/25/bioconf_icbb2025_03008.pdf
work_keys_str_mv AT linshenqi thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique
AT yuling thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique
AT hongruiting thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique
AT dongruncheng thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique
AT liubohao thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique
AT ruanwencong thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique
AT suntao thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique
AT zhoudongqing thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique
AT zhouyixuan thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique
AT chenshi thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique
AT linshenqi largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique
AT yuling largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique
AT hongruiting largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique
AT dongruncheng largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique
AT liubohao largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique
AT ruanwencong largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique
AT suntao largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique
AT zhoudongqing largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique
AT zhouyixuan largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique
AT chenshi largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique