The large, viscous thrombus is aspirated by using the cyclic suction technique
With the development of socio-economic conditions and changes in people’s lifestyles, particularly the acceleration of population aging and urbanization, unhealthy living habits among residents have become increasingly prominent. Cardiovascular disease (CVD) risk factors have a growing impact on pub...
Saved in:
| Main Authors: | , , , , , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
EDP Sciences
2025-01-01
|
| Series: | BIO Web of Conferences |
| Online Access: | https://www.bio-conferences.org/articles/bioconf/pdf/2025/25/bioconf_icbb2025_03008.pdf |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850267880861466624 |
|---|---|
| author | Lin Shenqi Yu Ling Hong Ruiting Dong Runcheng Liu Bohao Ruan Wencong Sun Tao Zhou Dongqing Zhou Yixuan Chen Shi |
| author_facet | Lin Shenqi Yu Ling Hong Ruiting Dong Runcheng Liu Bohao Ruan Wencong Sun Tao Zhou Dongqing Zhou Yixuan Chen Shi |
| author_sort | Lin Shenqi |
| collection | DOAJ |
| description | With the development of socio-economic conditions and changes in people’s lifestyles, particularly the acceleration of population aging and urbanization, unhealthy living habits among residents have become increasingly prominent. Cardiovascular disease (CVD) risk factors have a growing impact on public health, and the incidence of CVD continues to rise. Current research focuses mainly on improving the safety and effectiveness of thrombectomy devices and reducing complications during surgical procedures. Additionally, researchers are exploring the application of these devices in specific patient groups, such as those with comorbid conditions. This project introduces an intelligent device based on an MCU (Microcontroller Unit). Starting with the overall hardware system design, it includes the development of the device casing, selection of the MCU, and design of the internal pipeline length according to the pressure tolerance of the human inferior vena cava during thrombectomy. A pressure control valve and a pressure gauge are installed to ensure that the suction pressure remains within a safe range tolerable for the human body throughout the procedure. Pressure sensor data is then used to develop algorithms and control programs, enabling precise control of the opening and closing actions of the positive and negative pressure solenoid valves at specified intervals. By using optimal timing data, the suction tube of the device can generate impacts to break large thrombi while effectively preventing them from escaping to other parts of the vessel during the suction process, ensuring the smooth completion of thrombectomy. Through its unique design and precise operation, this device can more effectively remove thrombi from blood vessels, overcoming the limitations and risks of traditional treatment methods. This technological innovation not only advances the overall technical capabilities of the medical industry but also provides physicians with a more efficient and convenient treatment tool, further improving the quality and efficiency of medical services. Moreover, by rapidly and effectively removing thrombi, this treatment reduces patient hospitalization time and medication use, thereby lowering medical costs. As the technology becomes more widespread and its application more common, the cost of this treatment method is expected to decrease further, providing more patients with an affordable and effective treatment option. |
| format | Article |
| id | doaj-art-c0403bc7344f49f094d5effb866676ea |
| institution | OA Journals |
| issn | 2117-4458 |
| language | English |
| publishDate | 2025-01-01 |
| publisher | EDP Sciences |
| record_format | Article |
| series | BIO Web of Conferences |
| spelling | doaj-art-c0403bc7344f49f094d5effb866676ea2025-08-20T01:53:36ZengEDP SciencesBIO Web of Conferences2117-44582025-01-011740300810.1051/bioconf/202517403008bioconf_icbb2025_03008The large, viscous thrombus is aspirated by using the cyclic suction techniqueLin Shenqi0Yu Ling1Hong Ruiting2Dong Runcheng3Liu Bohao4Ruan Wencong5Sun Tao6Zhou Dongqing7Zhou Yixuan8Chen Shi9Shanghai Jian Qiao UniversityShanghai Jian Qiao UniversityShanghai Jian Qiao UniversityShanghai Jian Qiao UniversityShanghai Jian Qiao UniversityShanghai Jian Qiao UniversityShanghai Jian Qiao UniversityShanghai Jian Qiao UniversityShanghai Jian Qiao UniversityShanghai Jian Qiao UniversityWith the development of socio-economic conditions and changes in people’s lifestyles, particularly the acceleration of population aging and urbanization, unhealthy living habits among residents have become increasingly prominent. Cardiovascular disease (CVD) risk factors have a growing impact on public health, and the incidence of CVD continues to rise. Current research focuses mainly on improving the safety and effectiveness of thrombectomy devices and reducing complications during surgical procedures. Additionally, researchers are exploring the application of these devices in specific patient groups, such as those with comorbid conditions. This project introduces an intelligent device based on an MCU (Microcontroller Unit). Starting with the overall hardware system design, it includes the development of the device casing, selection of the MCU, and design of the internal pipeline length according to the pressure tolerance of the human inferior vena cava during thrombectomy. A pressure control valve and a pressure gauge are installed to ensure that the suction pressure remains within a safe range tolerable for the human body throughout the procedure. Pressure sensor data is then used to develop algorithms and control programs, enabling precise control of the opening and closing actions of the positive and negative pressure solenoid valves at specified intervals. By using optimal timing data, the suction tube of the device can generate impacts to break large thrombi while effectively preventing them from escaping to other parts of the vessel during the suction process, ensuring the smooth completion of thrombectomy. Through its unique design and precise operation, this device can more effectively remove thrombi from blood vessels, overcoming the limitations and risks of traditional treatment methods. This technological innovation not only advances the overall technical capabilities of the medical industry but also provides physicians with a more efficient and convenient treatment tool, further improving the quality and efficiency of medical services. Moreover, by rapidly and effectively removing thrombi, this treatment reduces patient hospitalization time and medication use, thereby lowering medical costs. As the technology becomes more widespread and its application more common, the cost of this treatment method is expected to decrease further, providing more patients with an affordable and effective treatment option.https://www.bio-conferences.org/articles/bioconf/pdf/2025/25/bioconf_icbb2025_03008.pdf |
| spellingShingle | Lin Shenqi Yu Ling Hong Ruiting Dong Runcheng Liu Bohao Ruan Wencong Sun Tao Zhou Dongqing Zhou Yixuan Chen Shi The large, viscous thrombus is aspirated by using the cyclic suction technique BIO Web of Conferences |
| title | The large, viscous thrombus is aspirated by using the cyclic suction technique |
| title_full | The large, viscous thrombus is aspirated by using the cyclic suction technique |
| title_fullStr | The large, viscous thrombus is aspirated by using the cyclic suction technique |
| title_full_unstemmed | The large, viscous thrombus is aspirated by using the cyclic suction technique |
| title_short | The large, viscous thrombus is aspirated by using the cyclic suction technique |
| title_sort | large viscous thrombus is aspirated by using the cyclic suction technique |
| url | https://www.bio-conferences.org/articles/bioconf/pdf/2025/25/bioconf_icbb2025_03008.pdf |
| work_keys_str_mv | AT linshenqi thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique AT yuling thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique AT hongruiting thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique AT dongruncheng thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique AT liubohao thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique AT ruanwencong thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique AT suntao thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique AT zhoudongqing thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique AT zhouyixuan thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique AT chenshi thelargeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique AT linshenqi largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique AT yuling largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique AT hongruiting largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique AT dongruncheng largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique AT liubohao largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique AT ruanwencong largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique AT suntao largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique AT zhoudongqing largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique AT zhouyixuan largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique AT chenshi largeviscousthrombusisaspiratedbyusingthecyclicsuctiontechnique |