Study on Operating Optimization of 660 MW Multi-stage Heating Unit Combined with Electric Boiler

Based on the analysis of multi-stage heating 660MW unit combined with electric boiler, the method of calculating the most economical high back pressure for unit real-time operation was put forward. The experiment proved that operating under the most economical high back pressure could effectively in...

Full description

Saved in:
Bibliographic Details
Main Authors: Jialun CHEN, Huanchun JIANG, Shaoshuai BIAN, Yingzhe KANG, Zhe WU, Xin HUANG
Format: Article
Language:zho
Published: State Grid Energy Research Institute 2022-05-01
Series:Zhongguo dianli
Subjects:
Online Access:https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202105118
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850226459518435328
author Jialun CHEN
Huanchun JIANG
Shaoshuai BIAN
Yingzhe KANG
Zhe WU
Xin HUANG
author_facet Jialun CHEN
Huanchun JIANG
Shaoshuai BIAN
Yingzhe KANG
Zhe WU
Xin HUANG
author_sort Jialun CHEN
collection DOAJ
description Based on the analysis of multi-stage heating 660MW unit combined with electric boiler, the method of calculating the most economical high back pressure for unit real-time operation was put forward. The experiment proved that operating under the most economical high back pressure could effectively increase the output power of the unit in controlling the main steam flow of the unit and the external heat load conditions and improve the thermal economy of unit. After the technical transformation, the heating capacity could be enhanced 440 GJ. When the external heating load was constant, multi-stage heating could decrease generator power by 86 MW and improved the peak load regulation capacity of the unit. The economy of the unit under the second gear peak shaving condition had been calculated. If the electric boiler replaced part of multi-stage heating under the same heat load, the unit conversion standard coal consumption increased by 0.32 t/h when the electric boiler load increased by 1 MW .
format Article
id doaj-art-bfabfe45adab43599e5b238d42e745eb
institution OA Journals
issn 1004-9649
language zho
publishDate 2022-05-01
publisher State Grid Energy Research Institute
record_format Article
series Zhongguo dianli
spelling doaj-art-bfabfe45adab43599e5b238d42e745eb2025-08-20T02:05:03ZzhoState Grid Energy Research InstituteZhongguo dianli1004-96492022-05-0155518919510.11930/j.issn.1004-9649.202105118zgdl-55-5-chenjialunStudy on Operating Optimization of 660 MW Multi-stage Heating Unit Combined with Electric BoilerJialun CHEN0Huanchun JIANG1Shaoshuai BIAN2Yingzhe KANG3Zhe WU4Xin HUANG5Shanghai Minghua Electric Power Technology Co., Ltd., Shanghai 200082, ChinaShanghai Minghua Electric Power Technology Co., Ltd., Shanghai 200082, ChinaShanghai Minghua Electric Power Technology Co., Ltd., Shanghai 200082, ChinaJilin Power Share Co., Ltd., Changchun 130022, ChinaBaicheng Power Generation Co., Ltd., Baicheng 137000, ChinaShanghai Minghua Electric Power Technology Co., Ltd., Shanghai 200082, ChinaBased on the analysis of multi-stage heating 660MW unit combined with electric boiler, the method of calculating the most economical high back pressure for unit real-time operation was put forward. The experiment proved that operating under the most economical high back pressure could effectively increase the output power of the unit in controlling the main steam flow of the unit and the external heat load conditions and improve the thermal economy of unit. After the technical transformation, the heating capacity could be enhanced 440 GJ. When the external heating load was constant, multi-stage heating could decrease generator power by 86 MW and improved the peak load regulation capacity of the unit. The economy of the unit under the second gear peak shaving condition had been calculated. If the electric boiler replaced part of multi-stage heating under the same heat load, the unit conversion standard coal consumption increased by 0.32 t/h when the electric boiler load increased by 1 MW .https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202105118multi-stage heatingmost economical high back pressureelectric boilereconomypeak load regulation
spellingShingle Jialun CHEN
Huanchun JIANG
Shaoshuai BIAN
Yingzhe KANG
Zhe WU
Xin HUANG
Study on Operating Optimization of 660 MW Multi-stage Heating Unit Combined with Electric Boiler
Zhongguo dianli
multi-stage heating
most economical high back pressure
electric boiler
economy
peak load regulation
title Study on Operating Optimization of 660 MW Multi-stage Heating Unit Combined with Electric Boiler
title_full Study on Operating Optimization of 660 MW Multi-stage Heating Unit Combined with Electric Boiler
title_fullStr Study on Operating Optimization of 660 MW Multi-stage Heating Unit Combined with Electric Boiler
title_full_unstemmed Study on Operating Optimization of 660 MW Multi-stage Heating Unit Combined with Electric Boiler
title_short Study on Operating Optimization of 660 MW Multi-stage Heating Unit Combined with Electric Boiler
title_sort study on operating optimization of 660 mw multi stage heating unit combined with electric boiler
topic multi-stage heating
most economical high back pressure
electric boiler
economy
peak load regulation
url https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202105118
work_keys_str_mv AT jialunchen studyonoperatingoptimizationof660mwmultistageheatingunitcombinedwithelectricboiler
AT huanchunjiang studyonoperatingoptimizationof660mwmultistageheatingunitcombinedwithelectricboiler
AT shaoshuaibian studyonoperatingoptimizationof660mwmultistageheatingunitcombinedwithelectricboiler
AT yingzhekang studyonoperatingoptimizationof660mwmultistageheatingunitcombinedwithelectricboiler
AT zhewu studyonoperatingoptimizationof660mwmultistageheatingunitcombinedwithelectricboiler
AT xinhuang studyonoperatingoptimizationof660mwmultistageheatingunitcombinedwithelectricboiler