A Constrained High-pressure Control Equation for CO2 Heat Pump Water Heating System
The optimization and control of discharge pressure is important in transcritical CO2 heat pump water heating systems. The traditional high-pressure control equation simply takes the exit temperature of the gas cooler into account, neglecting the impacts of the pinch point and the outlet temperature...
Saved in:
| Main Authors: | , , , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Journal of Refrigeration Magazines Agency Co., Ltd.
2018-01-01
|
| Series: | Zhileng xuebao |
| Subjects: | |
| Online Access: | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2018.01.020 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849705195934580736 |
|---|---|
| author | Wang Lei Liang Xingyu Shao Liangliang Zhang Chunlu |
| author_facet | Wang Lei Liang Xingyu Shao Liangliang Zhang Chunlu |
| author_sort | Wang Lei |
| collection | DOAJ |
| description | The optimization and control of discharge pressure is important in transcritical CO2 heat pump water heating systems. The traditional high-pressure control equation simply takes the exit temperature of the gas cooler into account, neglecting the impacts of the pinch point and the outlet temperature of water, which might lead to a huge coefficient of performance (COP) loss in applications. In this paper, we report the development of a constrained gas cooler model by considering the influence of the pinch point and water inlet and outlet temperatures. The main impact factors of the optimum high pressure are determined through the design of experiments and statistical methods. Consequently, a new constrained optimal high-pressure control equation using least-squares regression is proposed. Based on the new control equation, the system COP loss is 1.8% in average (maximum 8.7%), providing better reliability for engineering practices. |
| format | Article |
| id | doaj-art-be828fc21daf4fc8922514b19c66be1e |
| institution | DOAJ |
| issn | 0253-4339 |
| language | zho |
| publishDate | 2018-01-01 |
| publisher | Journal of Refrigeration Magazines Agency Co., Ltd. |
| record_format | Article |
| series | Zhileng xuebao |
| spelling | doaj-art-be828fc21daf4fc8922514b19c66be1e2025-08-20T03:16:32ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392018-01-013966509974A Constrained High-pressure Control Equation for CO2 Heat Pump Water Heating SystemWang LeiLiang XingyuShao LiangliangZhang ChunluThe optimization and control of discharge pressure is important in transcritical CO2 heat pump water heating systems. The traditional high-pressure control equation simply takes the exit temperature of the gas cooler into account, neglecting the impacts of the pinch point and the outlet temperature of water, which might lead to a huge coefficient of performance (COP) loss in applications. In this paper, we report the development of a constrained gas cooler model by considering the influence of the pinch point and water inlet and outlet temperatures. The main impact factors of the optimum high pressure are determined through the design of experiments and statistical methods. Consequently, a new constrained optimal high-pressure control equation using least-squares regression is proposed. Based on the new control equation, the system COP loss is 1.8% in average (maximum 8.7%), providing better reliability for engineering practices.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2018.01.020CO2 heat pump water heaterhigh pressure controlconstrained modeldesign of experiment |
| spellingShingle | Wang Lei Liang Xingyu Shao Liangliang Zhang Chunlu A Constrained High-pressure Control Equation for CO2 Heat Pump Water Heating System Zhileng xuebao CO2 heat pump water heater high pressure control constrained model design of experiment |
| title | A Constrained High-pressure Control Equation for CO2 Heat Pump Water Heating System |
| title_full | A Constrained High-pressure Control Equation for CO2 Heat Pump Water Heating System |
| title_fullStr | A Constrained High-pressure Control Equation for CO2 Heat Pump Water Heating System |
| title_full_unstemmed | A Constrained High-pressure Control Equation for CO2 Heat Pump Water Heating System |
| title_short | A Constrained High-pressure Control Equation for CO2 Heat Pump Water Heating System |
| title_sort | constrained high pressure control equation for co2 heat pump water heating system |
| topic | CO2 heat pump water heater high pressure control constrained model design of experiment |
| url | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2018.01.020 |
| work_keys_str_mv | AT wanglei aconstrainedhighpressurecontrolequationforco2heatpumpwaterheatingsystem AT liangxingyu aconstrainedhighpressurecontrolequationforco2heatpumpwaterheatingsystem AT shaoliangliang aconstrainedhighpressurecontrolequationforco2heatpumpwaterheatingsystem AT zhangchunlu aconstrainedhighpressurecontrolequationforco2heatpumpwaterheatingsystem AT wanglei constrainedhighpressurecontrolequationforco2heatpumpwaterheatingsystem AT liangxingyu constrainedhighpressurecontrolequationforco2heatpumpwaterheatingsystem AT shaoliangliang constrainedhighpressurecontrolequationforco2heatpumpwaterheatingsystem AT zhangchunlu constrainedhighpressurecontrolequationforco2heatpumpwaterheatingsystem |