Performance Analysis of a Greenhouse Fan-Pad Cooling System: Gradients of Horizontal Temperature and Relative Humidity

An experimental study was conducted to determine the performance parameters of system, as well as gradients of temperature and humidity along greenhouse when opening fan-ped cooling system. Measurements related with greenhouse environment were carried out by using seven sensors for different locatio...

Full description

Saved in:
Bibliographic Details
Main Authors: Mehmet Ali Dayıoğlu, Hasan Hüseyin Silleli
Format: Article
Language:English
Published: Ankara University 2014-12-01
Series:Journal of Agricultural Sciences
Subjects:
Online Access:https://dergipark.org.tr/tr/download/article-file/21152
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849764352851181568
author Mehmet Ali Dayıoğlu
Hasan Hüseyin Silleli
author_facet Mehmet Ali Dayıoğlu
Hasan Hüseyin Silleli
author_sort Mehmet Ali Dayıoğlu
collection DOAJ
description An experimental study was conducted to determine the performance parameters of system, as well as gradients of temperature and humidity along greenhouse when opening fan-ped cooling system. Measurements related with greenhouse environment were carried out by using seven sensors for different locations, as well as portable instruments. For this purpose, the five digital temperature and humidity sensors and two pyranometers were used during experiments. Among them, two were located outside greenhouse for external measurements. The rest one pyranometer above the crop canopy, four temperature and humidity sensors were mounted within the crop canopy along the greenhouse. Four sensors were placed according to positions defined between pad and fan. According to the experiment results, the non-uniform temperature changes, but approximately uniform humidity changes due to the crop transpiration were observed along greenhouse from pad panels to exhaust fans.When the cooling system closed, hourly mean temperature and relative humidity from pad to fan inside greenhouse changed between 30–33°C and 30–47%, respectively, at outside climate conditions of 32°C and 25%. After providing stabile cooling by opening fan-pad system, hourly mean temperature and relative humidity along greenhouse from pad to fan ranged between 20 – 27°C, and 50 – 68%, respectively. The air temperature entering to greenhouse with air velocity of 0.8–0.9 ms-1 through pad was approximately 12–13ºC lower than the outside air temperature. The air temperature from pad to fan increased approximately by 7 ºC.The method of psychrometric calculations was employed to determine the cooling efficiency of fan-pad system. According to the calculation result, the average of air temperatures inside greenhouse was 24.5 ºC after achieving stable cooling for outside air temperature of 31.4 ºC. The hourly mean cooling effect and cooling efficiency calculated for fan-pad system were determined to be 6.96ºC and 76.8%, respectively.
format Article
id doaj-art-be652cfcf97b410cb0de71bc44e7e90b
institution DOAJ
issn 1300-7580
2148-9297
language English
publishDate 2014-12-01
publisher Ankara University
record_format Article
series Journal of Agricultural Sciences
spelling doaj-art-be652cfcf97b410cb0de71bc44e7e90b2025-08-20T03:05:09ZengAnkara UniversityJournal of Agricultural Sciences1300-75802148-92972014-12-0121113214310.15832/tbd.2572145Performance Analysis of a Greenhouse Fan-Pad Cooling System: Gradients of Horizontal Temperature and Relative HumidityMehmet Ali DayıoğluHasan Hüseyin SilleliAn experimental study was conducted to determine the performance parameters of system, as well as gradients of temperature and humidity along greenhouse when opening fan-ped cooling system. Measurements related with greenhouse environment were carried out by using seven sensors for different locations, as well as portable instruments. For this purpose, the five digital temperature and humidity sensors and two pyranometers were used during experiments. Among them, two were located outside greenhouse for external measurements. The rest one pyranometer above the crop canopy, four temperature and humidity sensors were mounted within the crop canopy along the greenhouse. Four sensors were placed according to positions defined between pad and fan. According to the experiment results, the non-uniform temperature changes, but approximately uniform humidity changes due to the crop transpiration were observed along greenhouse from pad panels to exhaust fans.When the cooling system closed, hourly mean temperature and relative humidity from pad to fan inside greenhouse changed between 30–33°C and 30–47%, respectively, at outside climate conditions of 32°C and 25%. After providing stabile cooling by opening fan-pad system, hourly mean temperature and relative humidity along greenhouse from pad to fan ranged between 20 – 27°C, and 50 – 68%, respectively. The air temperature entering to greenhouse with air velocity of 0.8–0.9 ms-1 through pad was approximately 12–13ºC lower than the outside air temperature. The air temperature from pad to fan increased approximately by 7 ºC.The method of psychrometric calculations was employed to determine the cooling efficiency of fan-pad system. According to the calculation result, the average of air temperatures inside greenhouse was 24.5 ºC after achieving stable cooling for outside air temperature of 31.4 ºC. The hourly mean cooling effect and cooling efficiency calculated for fan-pad system were determined to be 6.96ºC and 76.8%, respectively.https://dergipark.org.tr/tr/download/article-file/21152greenhouse; fan-pad cooling system; temperature and relative humidity; psychrometric calculation; cooling efficiencysoğutma etkinliği fan-pad soğutma sistemi sera psikrometrik hesaplama sıcaklık ve bağıl nem
spellingShingle Mehmet Ali Dayıoğlu
Hasan Hüseyin Silleli
Performance Analysis of a Greenhouse Fan-Pad Cooling System: Gradients of Horizontal Temperature and Relative Humidity
Journal of Agricultural Sciences
greenhouse; fan-pad cooling system; temperature and relative humidity; psychrometric calculation; cooling efficiency
soğutma etkinliği
fan-pad soğutma sistemi
sera
psikrometrik hesaplama
sıcaklık ve bağıl nem
title Performance Analysis of a Greenhouse Fan-Pad Cooling System: Gradients of Horizontal Temperature and Relative Humidity
title_full Performance Analysis of a Greenhouse Fan-Pad Cooling System: Gradients of Horizontal Temperature and Relative Humidity
title_fullStr Performance Analysis of a Greenhouse Fan-Pad Cooling System: Gradients of Horizontal Temperature and Relative Humidity
title_full_unstemmed Performance Analysis of a Greenhouse Fan-Pad Cooling System: Gradients of Horizontal Temperature and Relative Humidity
title_short Performance Analysis of a Greenhouse Fan-Pad Cooling System: Gradients of Horizontal Temperature and Relative Humidity
title_sort performance analysis of a greenhouse fan pad cooling system gradients of horizontal temperature and relative humidity
topic greenhouse; fan-pad cooling system; temperature and relative humidity; psychrometric calculation; cooling efficiency
soğutma etkinliği
fan-pad soğutma sistemi
sera
psikrometrik hesaplama
sıcaklık ve bağıl nem
url https://dergipark.org.tr/tr/download/article-file/21152
work_keys_str_mv AT mehmetalidayıoglu performanceanalysisofagreenhousefanpadcoolingsystemgradientsofhorizontaltemperatureandrelativehumidity
AT hasanhuseyinsilleli performanceanalysisofagreenhousefanpadcoolingsystemgradientsofhorizontaltemperatureandrelativehumidity