Appreciation of influence of acquisition parameters in analysis of root canal using microCT system
Microtomography is successfully used in the odontological evaluation and treatments, as it´s capable to analyze the bone tissue and any possible damage in its root canal caused by a surgical intervention. In this study, the microCT was used to analyze the images by using different parameters in the...
Saved in:
| Main Authors: | , , , , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)
2021-04-01
|
| Series: | Brazilian Journal of Radiation Sciences |
| Subjects: | |
| Online Access: | https://bjrs.org.br/revista/index.php/REVISTA/article/view/1552 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850104656186834944 |
|---|---|
| author | Luan Ferreira Bastos Olga Maria Oliveira de Araújo Caio Márcio Sorrentino de Freitas Farias dos Santos Tâmara Porfíro Teixeira Renata Périssé Nobili Funcke João Carlos Rocha de Lima Alessandra Silveira Machado Davi Ferreira Oliveira Ricardo Tadeu Lopes |
| author_facet | Luan Ferreira Bastos Olga Maria Oliveira de Araújo Caio Márcio Sorrentino de Freitas Farias dos Santos Tâmara Porfíro Teixeira Renata Périssé Nobili Funcke João Carlos Rocha de Lima Alessandra Silveira Machado Davi Ferreira Oliveira Ricardo Tadeu Lopes |
| author_sort | Luan Ferreira Bastos |
| collection | DOAJ |
| description | Microtomography is successfully used in the odontological evaluation and treatments, as it´s capable to analyze the bone tissue and any possible damage in its root canal caused by a surgical intervention. In this study, the microCT was used to analyze the images by using different parameters in the acquisition process, as two matrix sizes: 1120x1120 pixels and 2240x2240 pixels. After the reconstruction, the volume of the root canal was analyzed, as well as the quantification of a remaining tooth closure material. The results showed that the detector array 1120X1120 was able to capture values close to those of the 2240x2240 matrix for the volume of root canal and for the residual material after treatment. Remaining tooth closure material correspond an average of 0.95 mm³ for 1120x1120 pixels, while the corresponding volume for 2240x2240 pixels was 0.90 mm³. Results for root canal volume average was 10.32 mm³ for 1120x1120 pixels, while for 2240x2240 pixels was 10.22 mm³. In this way, the difference of the detected volume between the two matrices is of 5.47% for the residual material and 0.93% for root canal volume. In a qualitative analyze, the 2240x2240 matrix allows the identification of a greater amount of details. However, it was possible to verify that depending on the application and the region of interest studied the smaller matrix can offer reliable results and a shorter processing time. |
| format | Article |
| id | doaj-art-be3609f7195d43d39e6db58d0dae87ef |
| institution | DOAJ |
| issn | 2319-0612 |
| language | English |
| publishDate | 2021-04-01 |
| publisher | Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR) |
| record_format | Article |
| series | Brazilian Journal of Radiation Sciences |
| spelling | doaj-art-be3609f7195d43d39e6db58d0dae87ef2025-08-20T02:39:16ZengBrazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)Brazilian Journal of Radiation Sciences2319-06122021-04-0191A10.15392/bjrs.v9i1A.15521206Appreciation of influence of acquisition parameters in analysis of root canal using microCT systemLuan Ferreira Bastos0Olga Maria Oliveira de AraújoCaio Márcio Sorrentino de Freitas Farias dos SantosTâmara Porfíro TeixeiraRenata Périssé Nobili FunckeJoão Carlos Rocha de LimaAlessandra Silveira MachadoDavi Ferreira OliveiraRicardo Tadeu LopesFederal University of Rio de JaneiroMicrotomography is successfully used in the odontological evaluation and treatments, as it´s capable to analyze the bone tissue and any possible damage in its root canal caused by a surgical intervention. In this study, the microCT was used to analyze the images by using different parameters in the acquisition process, as two matrix sizes: 1120x1120 pixels and 2240x2240 pixels. After the reconstruction, the volume of the root canal was analyzed, as well as the quantification of a remaining tooth closure material. The results showed that the detector array 1120X1120 was able to capture values close to those of the 2240x2240 matrix for the volume of root canal and for the residual material after treatment. Remaining tooth closure material correspond an average of 0.95 mm³ for 1120x1120 pixels, while the corresponding volume for 2240x2240 pixels was 0.90 mm³. Results for root canal volume average was 10.32 mm³ for 1120x1120 pixels, while for 2240x2240 pixels was 10.22 mm³. In this way, the difference of the detected volume between the two matrices is of 5.47% for the residual material and 0.93% for root canal volume. In a qualitative analyze, the 2240x2240 matrix allows the identification of a greater amount of details. However, it was possible to verify that depending on the application and the region of interest studied the smaller matrix can offer reliable results and a shorter processing time.https://bjrs.org.br/revista/index.php/REVISTA/article/view/1552microtomographyparameter comparisonroot canal study |
| spellingShingle | Luan Ferreira Bastos Olga Maria Oliveira de Araújo Caio Márcio Sorrentino de Freitas Farias dos Santos Tâmara Porfíro Teixeira Renata Périssé Nobili Funcke João Carlos Rocha de Lima Alessandra Silveira Machado Davi Ferreira Oliveira Ricardo Tadeu Lopes Appreciation of influence of acquisition parameters in analysis of root canal using microCT system Brazilian Journal of Radiation Sciences microtomography parameter comparison root canal study |
| title | Appreciation of influence of acquisition parameters in analysis of root canal using microCT system |
| title_full | Appreciation of influence of acquisition parameters in analysis of root canal using microCT system |
| title_fullStr | Appreciation of influence of acquisition parameters in analysis of root canal using microCT system |
| title_full_unstemmed | Appreciation of influence of acquisition parameters in analysis of root canal using microCT system |
| title_short | Appreciation of influence of acquisition parameters in analysis of root canal using microCT system |
| title_sort | appreciation of influence of acquisition parameters in analysis of root canal using microct system |
| topic | microtomography parameter comparison root canal study |
| url | https://bjrs.org.br/revista/index.php/REVISTA/article/view/1552 |
| work_keys_str_mv | AT luanferreirabastos appreciationofinfluenceofacquisitionparametersinanalysisofrootcanalusingmicroctsystem AT olgamariaoliveiradearaujo appreciationofinfluenceofacquisitionparametersinanalysisofrootcanalusingmicroctsystem AT caiomarciosorrentinodefreitasfariasdossantos appreciationofinfluenceofacquisitionparametersinanalysisofrootcanalusingmicroctsystem AT tamaraporfiroteixeira appreciationofinfluenceofacquisitionparametersinanalysisofrootcanalusingmicroctsystem AT renataperissenobilifuncke appreciationofinfluenceofacquisitionparametersinanalysisofrootcanalusingmicroctsystem AT joaocarlosrochadelima appreciationofinfluenceofacquisitionparametersinanalysisofrootcanalusingmicroctsystem AT alessandrasilveiramachado appreciationofinfluenceofacquisitionparametersinanalysisofrootcanalusingmicroctsystem AT daviferreiraoliveira appreciationofinfluenceofacquisitionparametersinanalysisofrootcanalusingmicroctsystem AT ricardotadeulopes appreciationofinfluenceofacquisitionparametersinanalysisofrootcanalusingmicroctsystem |