Appreciation of influence of acquisition parameters in analysis of root canal using microCT system

Microtomography is successfully used in the odontological evaluation and treatments, as it´s capable to analyze the bone tissue and any possible damage in its root canal caused by a surgical intervention. In this study, the microCT was used to analyze the images by using different parameters in the...

Full description

Saved in:
Bibliographic Details
Main Authors: Luan Ferreira Bastos, Olga Maria Oliveira de Araújo, Caio Márcio Sorrentino de Freitas Farias dos Santos, Tâmara Porfíro Teixeira, Renata Périssé Nobili Funcke, João Carlos Rocha de Lima, Alessandra Silveira Machado, Davi Ferreira Oliveira, Ricardo Tadeu Lopes
Format: Article
Language:English
Published: Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR) 2021-04-01
Series:Brazilian Journal of Radiation Sciences
Subjects:
Online Access:https://bjrs.org.br/revista/index.php/REVISTA/article/view/1552
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850104656186834944
author Luan Ferreira Bastos
Olga Maria Oliveira de Araújo
Caio Márcio Sorrentino de Freitas Farias dos Santos
Tâmara Porfíro Teixeira
Renata Périssé Nobili Funcke
João Carlos Rocha de Lima
Alessandra Silveira Machado
Davi Ferreira Oliveira
Ricardo Tadeu Lopes
author_facet Luan Ferreira Bastos
Olga Maria Oliveira de Araújo
Caio Márcio Sorrentino de Freitas Farias dos Santos
Tâmara Porfíro Teixeira
Renata Périssé Nobili Funcke
João Carlos Rocha de Lima
Alessandra Silveira Machado
Davi Ferreira Oliveira
Ricardo Tadeu Lopes
author_sort Luan Ferreira Bastos
collection DOAJ
description Microtomography is successfully used in the odontological evaluation and treatments, as it´s capable to analyze the bone tissue and any possible damage in its root canal caused by a surgical intervention. In this study, the microCT was used to analyze the images by using different parameters in the acquisition process, as two matrix sizes: 1120x1120 pixels and 2240x2240 pixels. After the reconstruction, the volume of the root canal was analyzed, as well as the quantification of a remaining tooth closure material. The results showed that the detector array 1120X1120 was able to capture values close to those of the 2240x2240 matrix for the volume of root canal and for the residual material after treatment. Remaining tooth closure material correspond an average of 0.95 mm³ for 1120x1120 pixels, while the corresponding volume for 2240x2240 pixels was 0.90 mm³. Results for root canal volume average was 10.32 mm³ for 1120x1120 pixels, while for 2240x2240 pixels was 10.22 mm³. In this way, the difference of the detected volume between the two matrices is of 5.47% for the residual material and 0.93% for root canal volume. In a qualitative analyze, the 2240x2240 matrix allows the identification of a greater amount of details. However, it was possible to verify that depending on the application and the region of interest studied the smaller matrix can offer reliable results and a shorter processing time.
format Article
id doaj-art-be3609f7195d43d39e6db58d0dae87ef
institution DOAJ
issn 2319-0612
language English
publishDate 2021-04-01
publisher Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)
record_format Article
series Brazilian Journal of Radiation Sciences
spelling doaj-art-be3609f7195d43d39e6db58d0dae87ef2025-08-20T02:39:16ZengBrazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)Brazilian Journal of Radiation Sciences2319-06122021-04-0191A10.15392/bjrs.v9i1A.15521206Appreciation of influence of acquisition parameters in analysis of root canal using microCT systemLuan Ferreira Bastos0Olga Maria Oliveira de AraújoCaio Márcio Sorrentino de Freitas Farias dos SantosTâmara Porfíro TeixeiraRenata Périssé Nobili FunckeJoão Carlos Rocha de LimaAlessandra Silveira MachadoDavi Ferreira OliveiraRicardo Tadeu LopesFederal University of Rio de JaneiroMicrotomography is successfully used in the odontological evaluation and treatments, as it´s capable to analyze the bone tissue and any possible damage in its root canal caused by a surgical intervention. In this study, the microCT was used to analyze the images by using different parameters in the acquisition process, as two matrix sizes: 1120x1120 pixels and 2240x2240 pixels. After the reconstruction, the volume of the root canal was analyzed, as well as the quantification of a remaining tooth closure material. The results showed that the detector array 1120X1120 was able to capture values close to those of the 2240x2240 matrix for the volume of root canal and for the residual material after treatment. Remaining tooth closure material correspond an average of 0.95 mm³ for 1120x1120 pixels, while the corresponding volume for 2240x2240 pixels was 0.90 mm³. Results for root canal volume average was 10.32 mm³ for 1120x1120 pixels, while for 2240x2240 pixels was 10.22 mm³. In this way, the difference of the detected volume between the two matrices is of 5.47% for the residual material and 0.93% for root canal volume. In a qualitative analyze, the 2240x2240 matrix allows the identification of a greater amount of details. However, it was possible to verify that depending on the application and the region of interest studied the smaller matrix can offer reliable results and a shorter processing time.https://bjrs.org.br/revista/index.php/REVISTA/article/view/1552microtomographyparameter comparisonroot canal study
spellingShingle Luan Ferreira Bastos
Olga Maria Oliveira de Araújo
Caio Márcio Sorrentino de Freitas Farias dos Santos
Tâmara Porfíro Teixeira
Renata Périssé Nobili Funcke
João Carlos Rocha de Lima
Alessandra Silveira Machado
Davi Ferreira Oliveira
Ricardo Tadeu Lopes
Appreciation of influence of acquisition parameters in analysis of root canal using microCT system
Brazilian Journal of Radiation Sciences
microtomography
parameter comparison
root canal study
title Appreciation of influence of acquisition parameters in analysis of root canal using microCT system
title_full Appreciation of influence of acquisition parameters in analysis of root canal using microCT system
title_fullStr Appreciation of influence of acquisition parameters in analysis of root canal using microCT system
title_full_unstemmed Appreciation of influence of acquisition parameters in analysis of root canal using microCT system
title_short Appreciation of influence of acquisition parameters in analysis of root canal using microCT system
title_sort appreciation of influence of acquisition parameters in analysis of root canal using microct system
topic microtomography
parameter comparison
root canal study
url https://bjrs.org.br/revista/index.php/REVISTA/article/view/1552
work_keys_str_mv AT luanferreirabastos appreciationofinfluenceofacquisitionparametersinanalysisofrootcanalusingmicroctsystem
AT olgamariaoliveiradearaujo appreciationofinfluenceofacquisitionparametersinanalysisofrootcanalusingmicroctsystem
AT caiomarciosorrentinodefreitasfariasdossantos appreciationofinfluenceofacquisitionparametersinanalysisofrootcanalusingmicroctsystem
AT tamaraporfiroteixeira appreciationofinfluenceofacquisitionparametersinanalysisofrootcanalusingmicroctsystem
AT renataperissenobilifuncke appreciationofinfluenceofacquisitionparametersinanalysisofrootcanalusingmicroctsystem
AT joaocarlosrochadelima appreciationofinfluenceofacquisitionparametersinanalysisofrootcanalusingmicroctsystem
AT alessandrasilveiramachado appreciationofinfluenceofacquisitionparametersinanalysisofrootcanalusingmicroctsystem
AT daviferreiraoliveira appreciationofinfluenceofacquisitionparametersinanalysisofrootcanalusingmicroctsystem
AT ricardotadeulopes appreciationofinfluenceofacquisitionparametersinanalysisofrootcanalusingmicroctsystem