Multidimensional Sternal Fixation to Overcome a “Floating” Sternum
This case report describes the repair of a complete sternal dehiscence of the lower right sternum using sternal wires, manubrial plates, and a Talon closure device for rigid, multidimensional sternal fixation. Sternal dehiscence is a rare but significant cause of morbidity for patients undergoing m...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2014-01-01
|
Series: | Case Reports in Surgery |
Online Access: | http://dx.doi.org/10.1155/2014/690160 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832548348432744448 |
---|---|
author | William Rothstein Tyler Spata Bryan Whitson Ahmet Kilic |
author_facet | William Rothstein Tyler Spata Bryan Whitson Ahmet Kilic |
author_sort | William Rothstein |
collection | DOAJ |
description | This case report describes the repair of a complete sternal dehiscence of the lower right sternum using sternal wires, manubrial plates, and a Talon closure device for rigid, multidimensional sternal fixation. Sternal dehiscence is a rare but significant cause of morbidity for patients undergoing median sternotomy. The risk factors for this complication are well described and although sternal wires have traditionally been used for primary closure, rigid fixation with sternal plates is a viable alternative to avoid dehiscence in this high-risk cohort. |
format | Article |
id | doaj-art-bddf70f47d3f40faa133ee014a16911d |
institution | Kabale University |
issn | 2090-6900 2090-6919 |
language | English |
publishDate | 2014-01-01 |
publisher | Wiley |
record_format | Article |
series | Case Reports in Surgery |
spelling | doaj-art-bddf70f47d3f40faa133ee014a16911d2025-02-03T06:14:16ZengWileyCase Reports in Surgery2090-69002090-69192014-01-01201410.1155/2014/690160690160Multidimensional Sternal Fixation to Overcome a “Floating” SternumWilliam Rothstein0Tyler Spata1Bryan Whitson2Ahmet Kilic3Department of Surgery, The Ohio State University Wexner Medical Center, 410 W. 10th Avenue, Columbus, OH 43210, USADepartment of Surgery, The Ohio State University Wexner Medical Center, 410 W. 10th Avenue, Columbus, OH 43210, USADepartment of Surgery, The Ohio State University Wexner Medical Center, 410 W. 10th Avenue, Columbus, OH 43210, USADepartment of Surgery, The Ohio State University Wexner Medical Center, 410 W. 10th Avenue, Columbus, OH 43210, USAThis case report describes the repair of a complete sternal dehiscence of the lower right sternum using sternal wires, manubrial plates, and a Talon closure device for rigid, multidimensional sternal fixation. Sternal dehiscence is a rare but significant cause of morbidity for patients undergoing median sternotomy. The risk factors for this complication are well described and although sternal wires have traditionally been used for primary closure, rigid fixation with sternal plates is a viable alternative to avoid dehiscence in this high-risk cohort.http://dx.doi.org/10.1155/2014/690160 |
spellingShingle | William Rothstein Tyler Spata Bryan Whitson Ahmet Kilic Multidimensional Sternal Fixation to Overcome a “Floating” Sternum Case Reports in Surgery |
title | Multidimensional Sternal Fixation to Overcome a “Floating” Sternum |
title_full | Multidimensional Sternal Fixation to Overcome a “Floating” Sternum |
title_fullStr | Multidimensional Sternal Fixation to Overcome a “Floating” Sternum |
title_full_unstemmed | Multidimensional Sternal Fixation to Overcome a “Floating” Sternum |
title_short | Multidimensional Sternal Fixation to Overcome a “Floating” Sternum |
title_sort | multidimensional sternal fixation to overcome a floating sternum |
url | http://dx.doi.org/10.1155/2014/690160 |
work_keys_str_mv | AT williamrothstein multidimensionalsternalfixationtoovercomeafloatingsternum AT tylerspata multidimensionalsternalfixationtoovercomeafloatingsternum AT bryanwhitson multidimensionalsternalfixationtoovercomeafloatingsternum AT ahmetkilic multidimensionalsternalfixationtoovercomeafloatingsternum |