Simultaneous determination of 13 non-phthalate plasticizers in strong-flavor Baijiu by gas chromatography-mass spectrometry

A method for the simultaneous determination of 13 non-phthalate plasticizers in strong-flavor (Nongxiangxing) Baijiu by gas chromatography- mass spectrometry (GC-MS) was established. The alcohol content of sample was diluted with water to about 20%vol, then extracted with n-hexane, and then extracte...

Full description

Saved in:
Bibliographic Details
Main Author: RAN Yifan, HE Cheng, WANG Ming, AO Zonghua, LIAO Yuan, YANG Qin, DONG Liang, LI Chenyang, LIU Yalan
Format: Article
Language:English
Published: Editorial Department of China Brewing 2025-05-01
Series:Zhongguo niangzao
Subjects:
Online Access:https://manu61.magtech.com.cn/zgnz/fileup/0254-5071/PDF/0254-5071-2025-44-5-266.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A method for the simultaneous determination of 13 non-phthalate plasticizers in strong-flavor (Nongxiangxing) Baijiu by gas chromatography- mass spectrometry (GC-MS) was established. The alcohol content of sample was diluted with water to about 20%vol, then extracted with n-hexane, and then extracted twice by vortex, ultrasound and centrifugation. The extracted solution was combined and concentrated by nitrogen blowing and then re-dissolved. The chromatographic column was Agilent HP-5MS column (30 m&#x00D7;0.25 mm&#x00D7;0.25 μm), the inlet temperature was 280 ℃, and the initial temperature of column oven was 70 ℃. A variety of non-phthalate plasticizers were detected by select ion monitoring (SIM) mode and quantified by external standard method. The results showed that the 13 non-phthalate plasticizers had a good linear relationship in the range of 0.02-1.0 mg/L, the correlation coefficient (R<sup>2</sup>)≥0.996 2, the limit of detection (LOD) were 0.002-0.05 mg/kg, and the limit of quantification (LOQ) were 0.006-0.15 mg/kg; The average standard recovery rates were 55.9%-113.8%, and the relative standard deviation (RSD) of precision tests results were 1.0%-8.8%. The method was accurate, efficient, rapid and simple, and could be used for the qualitative and quantitative detection of a variety of non-phthalate plasticizers in Baijiu.
ISSN:0254-5071