Monte Carlo Simulation for Polychromatic X-Ray Fluorescence Computed Tomography with Sheet-Beam Geometry

X-ray fluorescence computed tomography (XFCT) based on sheet beam can save a huge amount of time to obtain a whole set of projections using synchrotron. However, it is clearly unpractical for most biomedical research laboratories. In this paper, polychromatic X-ray fluorescence computed tomography w...

Full description

Saved in:
Bibliographic Details
Main Authors: Shanghai Jiang, Peng He, Luzhen Deng, Mianyi Chen, Biao Wei
Format: Article
Language:English
Published: Wiley 2017-01-01
Series:International Journal of Biomedical Imaging
Online Access:http://dx.doi.org/10.1155/2017/7916260
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850177962866900992
author Shanghai Jiang
Peng He
Luzhen Deng
Mianyi Chen
Biao Wei
author_facet Shanghai Jiang
Peng He
Luzhen Deng
Mianyi Chen
Biao Wei
author_sort Shanghai Jiang
collection DOAJ
description X-ray fluorescence computed tomography (XFCT) based on sheet beam can save a huge amount of time to obtain a whole set of projections using synchrotron. However, it is clearly unpractical for most biomedical research laboratories. In this paper, polychromatic X-ray fluorescence computed tomography with sheet-beam geometry is tested by Monte Carlo simulation. First, two phantoms (A and B) filled with PMMA are used to simulate imaging process through GEANT 4. Phantom A contains several GNP-loaded regions with the same size (10 mm) in height and diameter but different Au weight concentration ranging from 0.3% to 1.8%. Phantom B contains twelve GNP-loaded regions with the same Au weight concentration (1.6%) but different diameter ranging from 1 mm to 9 mm. Second, discretized presentation of imaging model is established to reconstruct more accurate XFCT images. Third, XFCT images of phantoms A and B are reconstructed by filter back-projection (FBP) and maximum likelihood expectation maximization (MLEM) with and without correction, respectively. Contrast-to-noise ratio (CNR) is calculated to evaluate all the reconstructed images. Our results show that it is feasible for sheet-beam XFCT system based on polychromatic X-ray source and the discretized imaging model can be used to reconstruct more accurate images.
format Article
id doaj-art-bcfba38e5fab4ac9980558943c91fd6b
institution OA Journals
issn 1687-4188
1687-4196
language English
publishDate 2017-01-01
publisher Wiley
record_format Article
series International Journal of Biomedical Imaging
spelling doaj-art-bcfba38e5fab4ac9980558943c91fd6b2025-08-20T02:18:51ZengWileyInternational Journal of Biomedical Imaging1687-41881687-41962017-01-01201710.1155/2017/79162607916260Monte Carlo Simulation for Polychromatic X-Ray Fluorescence Computed Tomography with Sheet-Beam GeometryShanghai Jiang0Peng He1Luzhen Deng2Mianyi Chen3Biao Wei4Key Lab of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing 400044, ChinaKey Lab of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing 400044, ChinaKey Lab of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing 400044, ChinaKey Lab of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing 400044, ChinaKey Lab of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing 400044, ChinaX-ray fluorescence computed tomography (XFCT) based on sheet beam can save a huge amount of time to obtain a whole set of projections using synchrotron. However, it is clearly unpractical for most biomedical research laboratories. In this paper, polychromatic X-ray fluorescence computed tomography with sheet-beam geometry is tested by Monte Carlo simulation. First, two phantoms (A and B) filled with PMMA are used to simulate imaging process through GEANT 4. Phantom A contains several GNP-loaded regions with the same size (10 mm) in height and diameter but different Au weight concentration ranging from 0.3% to 1.8%. Phantom B contains twelve GNP-loaded regions with the same Au weight concentration (1.6%) but different diameter ranging from 1 mm to 9 mm. Second, discretized presentation of imaging model is established to reconstruct more accurate XFCT images. Third, XFCT images of phantoms A and B are reconstructed by filter back-projection (FBP) and maximum likelihood expectation maximization (MLEM) with and without correction, respectively. Contrast-to-noise ratio (CNR) is calculated to evaluate all the reconstructed images. Our results show that it is feasible for sheet-beam XFCT system based on polychromatic X-ray source and the discretized imaging model can be used to reconstruct more accurate images.http://dx.doi.org/10.1155/2017/7916260
spellingShingle Shanghai Jiang
Peng He
Luzhen Deng
Mianyi Chen
Biao Wei
Monte Carlo Simulation for Polychromatic X-Ray Fluorescence Computed Tomography with Sheet-Beam Geometry
International Journal of Biomedical Imaging
title Monte Carlo Simulation for Polychromatic X-Ray Fluorescence Computed Tomography with Sheet-Beam Geometry
title_full Monte Carlo Simulation for Polychromatic X-Ray Fluorescence Computed Tomography with Sheet-Beam Geometry
title_fullStr Monte Carlo Simulation for Polychromatic X-Ray Fluorescence Computed Tomography with Sheet-Beam Geometry
title_full_unstemmed Monte Carlo Simulation for Polychromatic X-Ray Fluorescence Computed Tomography with Sheet-Beam Geometry
title_short Monte Carlo Simulation for Polychromatic X-Ray Fluorescence Computed Tomography with Sheet-Beam Geometry
title_sort monte carlo simulation for polychromatic x ray fluorescence computed tomography with sheet beam geometry
url http://dx.doi.org/10.1155/2017/7916260
work_keys_str_mv AT shanghaijiang montecarlosimulationforpolychromaticxrayfluorescencecomputedtomographywithsheetbeamgeometry
AT penghe montecarlosimulationforpolychromaticxrayfluorescencecomputedtomographywithsheetbeamgeometry
AT luzhendeng montecarlosimulationforpolychromaticxrayfluorescencecomputedtomographywithsheetbeamgeometry
AT mianyichen montecarlosimulationforpolychromaticxrayfluorescencecomputedtomographywithsheetbeamgeometry
AT biaowei montecarlosimulationforpolychromaticxrayfluorescencecomputedtomographywithsheetbeamgeometry