Spontaneous Resolution of Hemolysis After Ventricular Septal Defect Closure With an Amplatzer Device

ABSTRACT A wait and see approach can be maintained in cases with mechanical hemolysis after percutaneous VSD closure, even when the cause is not homogeneous.

Saved in:
Bibliographic Details
Main Authors: Christophe Popelier, Pieter De Meester, Werner Budts
Format: Article
Language:English
Published: Wiley 2025-08-01
Series:Clinical Case Reports
Subjects:
Online Access:https://doi.org/10.1002/ccr3.70613
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849229042683740160
author Christophe Popelier
Pieter De Meester
Werner Budts
author_facet Christophe Popelier
Pieter De Meester
Werner Budts
author_sort Christophe Popelier
collection DOAJ
description ABSTRACT A wait and see approach can be maintained in cases with mechanical hemolysis after percutaneous VSD closure, even when the cause is not homogeneous.
format Article
id doaj-art-bcbc867e4736481a956f3571968be0df
institution Kabale University
issn 2050-0904
language English
publishDate 2025-08-01
publisher Wiley
record_format Article
series Clinical Case Reports
spelling doaj-art-bcbc867e4736481a956f3571968be0df2025-08-22T07:33:08ZengWileyClinical Case Reports2050-09042025-08-01138n/an/a10.1002/ccr3.70613Spontaneous Resolution of Hemolysis After Ventricular Septal Defect Closure With an Amplatzer DeviceChristophe Popelier0Pieter De Meester1Werner Budts2Leuven, Congenital and Structural Cardiology UZ Leuven Leuven BelgiumLeuven, Congenital and Structural Cardiology UZ Leuven Leuven BelgiumLeuven, Congenital and Structural Cardiology UZ Leuven Leuven BelgiumABSTRACT A wait and see approach can be maintained in cases with mechanical hemolysis after percutaneous VSD closure, even when the cause is not homogeneous.https://doi.org/10.1002/ccr3.70613Amplatzer Occluder devicecongenital heart defectintravascular hemolysisventricular heart septal defects
spellingShingle Christophe Popelier
Pieter De Meester
Werner Budts
Spontaneous Resolution of Hemolysis After Ventricular Septal Defect Closure With an Amplatzer Device
Clinical Case Reports
Amplatzer Occluder device
congenital heart defect
intravascular hemolysis
ventricular heart septal defects
title Spontaneous Resolution of Hemolysis After Ventricular Septal Defect Closure With an Amplatzer Device
title_full Spontaneous Resolution of Hemolysis After Ventricular Septal Defect Closure With an Amplatzer Device
title_fullStr Spontaneous Resolution of Hemolysis After Ventricular Septal Defect Closure With an Amplatzer Device
title_full_unstemmed Spontaneous Resolution of Hemolysis After Ventricular Septal Defect Closure With an Amplatzer Device
title_short Spontaneous Resolution of Hemolysis After Ventricular Septal Defect Closure With an Amplatzer Device
title_sort spontaneous resolution of hemolysis after ventricular septal defect closure with an amplatzer device
topic Amplatzer Occluder device
congenital heart defect
intravascular hemolysis
ventricular heart septal defects
url https://doi.org/10.1002/ccr3.70613
work_keys_str_mv AT christophepopelier spontaneousresolutionofhemolysisafterventricularseptaldefectclosurewithanamplatzerdevice
AT pieterdemeester spontaneousresolutionofhemolysisafterventricularseptaldefectclosurewithanamplatzerdevice
AT wernerbudts spontaneousresolutionofhemolysisafterventricularseptaldefectclosurewithanamplatzerdevice