Novel multilayer meniscal scaffold provides biomechanical and histological results comparable to polyurethane scaffolds: An 8 week rabbit study

Objective: The aim of this study was to evaluate the meniscal regeneration and arthritic changes after partial meniscectomy and application of either polyurethane scaffold or novel multilayer meniscal scaffold in a rabbit model. Methods: Sixteen NewZealand rabbits were randomly divided into three gr...

Full description

Saved in:
Bibliographic Details
Main Authors: Nihat Demirhan Demirkıran, Hasan Havıtçıoğlu, Aylin Ziylan, Ülker Cankurt, Buğra Hüsemoğlu
Format: Article
Language:English
Published: AVES 2019-03-01
Series:Acta Orthopaedica et Traumatologica Turcica
Online Access:http://www.sciencedirect.com/science/article/pii/S1017995X18303377
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849396082428084224
author Nihat Demirhan Demirkıran
Hasan Havıtçıoğlu
Aylin Ziylan
Ülker Cankurt
Buğra Hüsemoğlu
author_facet Nihat Demirhan Demirkıran
Hasan Havıtçıoğlu
Aylin Ziylan
Ülker Cankurt
Buğra Hüsemoğlu
author_sort Nihat Demirhan Demirkıran
collection DOAJ
description Objective: The aim of this study was to evaluate the meniscal regeneration and arthritic changes after partial meniscectomy and application of either polyurethane scaffold or novel multilayer meniscal scaffold in a rabbit model. Methods: Sixteen NewZealand rabbits were randomly divided into three groups. A reproducible 1.5-mm cylindrical defect was created in the avascular zone of the anterior horn of the medial meniscus bilaterally. Defects were filled with the polyurethane scaffold in Group 1 (n:6) and with novel multilayer scaffold in Group 2 (n:6). Rabbits in Group 3 (n:4) did not receive any treatment and defects were left empty. All animals were sacrificed after 8 weeks and bilateral knee joints were taken for macroscopic, biomechanical, and histological analysis. After excision of menisci, inked condylar surfaces and tibial plateaus were evaluated for arthritic changes. Digital photographs of excised menisci were also obtained and surface areas were measured by a computer software. Indentation testing of the tibial condyles and compression tests for the relevant meniscal areas was also performed in all groups. Histological analysis was made and all specimens were scored according to Rodeo scoring system. Results: No signs of inflammation or infection were observed in any animals. A significant difference was observed between meniscus surface areas of the multilayer scaffold group (20.13 ± 1.91 mm2) and the group with empty meniscus defects (15.62 ± 2.04 mm2) (p = 0.047). The results of biomechanical compression tests revealed a significant difference between the Hayes scores of the second group (1.728) and the empty defect group (0,467) (p = 0.029). Intact meniscal tissue showed higher mechanical properties than all the defected samples. Multilayer scaffold group demonstrated the closest results compared to healthy meniscus tissue. Tibia indentation tests and histological evaluation showed no significant differences between groups (p = 0.401 and p = 0.186 respectively). Conclusions: In this study, the initial evaluation of novel multilayer meniscal scaffold prevented the shrinkage that may occur in the meniscus area and demonstrated superior biomechanical results compared to empty defects. No adverse events related to scaffold material was observed. Besides, promising biomechanical and histological results, comparable to polyurethane scaffold, were obtained. Keywords: Meniscal scaffold, Multi-layer meniscus scaffold, Composite scaffold, PHBV, Luffa Cylindirica fiber, Strontium ranelate
format Article
id doaj-art-bcb642938d5d40fca192b251fb44f732
institution Kabale University
issn 1017-995X
language English
publishDate 2019-03-01
publisher AVES
record_format Article
series Acta Orthopaedica et Traumatologica Turcica
spelling doaj-art-bcb642938d5d40fca192b251fb44f7322025-08-20T03:39:26ZengAVESActa Orthopaedica et Traumatologica Turcica1017-995X2019-03-0153212012810.1016/j.aott.2019.02.004Novel multilayer meniscal scaffold provides biomechanical and histological results comparable to polyurethane scaffolds: An 8 week rabbit studyNihat Demirhan Demirkıran0Hasan Havıtçıoğlu1Aylin Ziylan2Ülker Cankurt3Buğra Hüsemoğlu4Department of Orthopedics, Dumlupinar University Evliya Celebi Education and Research Hospital, Kutahya, Turkey; Corresponding author. Department of Orthopedics, Dumlupinar University Evliya Celebi Education and Research Hospital, 43040, Kutahya, Turkey.Department of Orthopedics, Dokuz Eylul University Hospital, Izmir, TurkeyFaculty of Engineering, Dokuz Eylul University, Izmir, TurkeyDepartment of Histology, Dokuz Eylul University Hospital, Izmir, TurkeyDepartment of Biomechanics, Dokuz Eylul University Hospital, Izmir, TurkeyObjective: The aim of this study was to evaluate the meniscal regeneration and arthritic changes after partial meniscectomy and application of either polyurethane scaffold or novel multilayer meniscal scaffold in a rabbit model. Methods: Sixteen NewZealand rabbits were randomly divided into three groups. A reproducible 1.5-mm cylindrical defect was created in the avascular zone of the anterior horn of the medial meniscus bilaterally. Defects were filled with the polyurethane scaffold in Group 1 (n:6) and with novel multilayer scaffold in Group 2 (n:6). Rabbits in Group 3 (n:4) did not receive any treatment and defects were left empty. All animals were sacrificed after 8 weeks and bilateral knee joints were taken for macroscopic, biomechanical, and histological analysis. After excision of menisci, inked condylar surfaces and tibial plateaus were evaluated for arthritic changes. Digital photographs of excised menisci were also obtained and surface areas were measured by a computer software. Indentation testing of the tibial condyles and compression tests for the relevant meniscal areas was also performed in all groups. Histological analysis was made and all specimens were scored according to Rodeo scoring system. Results: No signs of inflammation or infection were observed in any animals. A significant difference was observed between meniscus surface areas of the multilayer scaffold group (20.13 ± 1.91 mm2) and the group with empty meniscus defects (15.62 ± 2.04 mm2) (p = 0.047). The results of biomechanical compression tests revealed a significant difference between the Hayes scores of the second group (1.728) and the empty defect group (0,467) (p = 0.029). Intact meniscal tissue showed higher mechanical properties than all the defected samples. Multilayer scaffold group demonstrated the closest results compared to healthy meniscus tissue. Tibia indentation tests and histological evaluation showed no significant differences between groups (p = 0.401 and p = 0.186 respectively). Conclusions: In this study, the initial evaluation of novel multilayer meniscal scaffold prevented the shrinkage that may occur in the meniscus area and demonstrated superior biomechanical results compared to empty defects. No adverse events related to scaffold material was observed. Besides, promising biomechanical and histological results, comparable to polyurethane scaffold, were obtained. Keywords: Meniscal scaffold, Multi-layer meniscus scaffold, Composite scaffold, PHBV, Luffa Cylindirica fiber, Strontium ranelatehttp://www.sciencedirect.com/science/article/pii/S1017995X18303377
spellingShingle Nihat Demirhan Demirkıran
Hasan Havıtçıoğlu
Aylin Ziylan
Ülker Cankurt
Buğra Hüsemoğlu
Novel multilayer meniscal scaffold provides biomechanical and histological results comparable to polyurethane scaffolds: An 8 week rabbit study
Acta Orthopaedica et Traumatologica Turcica
title Novel multilayer meniscal scaffold provides biomechanical and histological results comparable to polyurethane scaffolds: An 8 week rabbit study
title_full Novel multilayer meniscal scaffold provides biomechanical and histological results comparable to polyurethane scaffolds: An 8 week rabbit study
title_fullStr Novel multilayer meniscal scaffold provides biomechanical and histological results comparable to polyurethane scaffolds: An 8 week rabbit study
title_full_unstemmed Novel multilayer meniscal scaffold provides biomechanical and histological results comparable to polyurethane scaffolds: An 8 week rabbit study
title_short Novel multilayer meniscal scaffold provides biomechanical and histological results comparable to polyurethane scaffolds: An 8 week rabbit study
title_sort novel multilayer meniscal scaffold provides biomechanical and histological results comparable to polyurethane scaffolds an 8 week rabbit study
url http://www.sciencedirect.com/science/article/pii/S1017995X18303377
work_keys_str_mv AT nihatdemirhandemirkıran novelmultilayermeniscalscaffoldprovidesbiomechanicalandhistologicalresultscomparabletopolyurethanescaffoldsan8weekrabbitstudy
AT hasanhavıtcıoglu novelmultilayermeniscalscaffoldprovidesbiomechanicalandhistologicalresultscomparabletopolyurethanescaffoldsan8weekrabbitstudy
AT aylinziylan novelmultilayermeniscalscaffoldprovidesbiomechanicalandhistologicalresultscomparabletopolyurethanescaffoldsan8weekrabbitstudy
AT ulkercankurt novelmultilayermeniscalscaffoldprovidesbiomechanicalandhistologicalresultscomparabletopolyurethanescaffoldsan8weekrabbitstudy
AT bugrahusemoglu novelmultilayermeniscalscaffoldprovidesbiomechanicalandhistologicalresultscomparabletopolyurethanescaffoldsan8weekrabbitstudy