Application of Quasi Proportional Resonance Control Algorithm in Three-phase Inverter Power

Nonlinear loads introduce harmonics into the three-phase inverter power system, which damages the electrical equipment. In order to reduce the harmonic content of the inverter output voltage, a harmonic suppression method based on the quasi-proportional resonance control algorithm was proposed. The...

Full description

Saved in:
Bibliographic Details
Main Authors: Weiwei GAN, Wei GUO, Ke CHEN, Wentao WANG, Minggao ZENG, Xuebiao PENG
Format: Article
Language:zho
Published: Editorial Department of Electric Drive for Locomotives 2020-03-01
Series:机车电传动
Subjects:
Online Access:http://edl.csrzic.com/thesisDetails#10.13890/j.issn.1000-128x.2020.02.012
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849728786220711936
author Weiwei GAN
Wei GUO
Ke CHEN
Wentao WANG
Minggao ZENG
Xuebiao PENG
author_facet Weiwei GAN
Wei GUO
Ke CHEN
Wentao WANG
Minggao ZENG
Xuebiao PENG
author_sort Weiwei GAN
collection DOAJ
description Nonlinear loads introduce harmonics into the three-phase inverter power system, which damages the electrical equipment. In order to reduce the harmonic content of the inverter output voltage, a harmonic suppression method based on the quasi-proportional resonance control algorithm was proposed. The proposed method mainly suppresses the 5th and 7th harmonics of the inverter output voltage. The traditional instantaneous control method and quasi-proportional resonance method were tested by simulation models and physical experiments. Results show that the quasi-proportional resonance can eliminate specific harmonics in the output voltage, meets the requirements of system dynamic response performance and steady-state accuracy and has a good harmonic suppression effect.
format Article
id doaj-art-bc8284d44e0144e29a272cf7116da84b
institution DOAJ
issn 1000-128X
language zho
publishDate 2020-03-01
publisher Editorial Department of Electric Drive for Locomotives
record_format Article
series 机车电传动
spelling doaj-art-bc8284d44e0144e29a272cf7116da84b2025-08-20T03:09:27ZzhoEditorial Department of Electric Drive for Locomotives机车电传动1000-128X2020-03-015861,11720921384Application of Quasi Proportional Resonance Control Algorithm in Three-phase Inverter PowerWeiwei GANWei GUOKe CHENWentao WANGMinggao ZENGXuebiao PENGNonlinear loads introduce harmonics into the three-phase inverter power system, which damages the electrical equipment. In order to reduce the harmonic content of the inverter output voltage, a harmonic suppression method based on the quasi-proportional resonance control algorithm was proposed. The proposed method mainly suppresses the 5th and 7th harmonics of the inverter output voltage. The traditional instantaneous control method and quasi-proportional resonance method were tested by simulation models and physical experiments. Results show that the quasi-proportional resonance can eliminate specific harmonics in the output voltage, meets the requirements of system dynamic response performance and steady-state accuracy and has a good harmonic suppression effect.http://edl.csrzic.com/thesisDetails#10.13890/j.issn.1000-128x.2020.02.012inverter powernonlinear loadsquasi-proportional resonanceharmonic suppressionsimulation
spellingShingle Weiwei GAN
Wei GUO
Ke CHEN
Wentao WANG
Minggao ZENG
Xuebiao PENG
Application of Quasi Proportional Resonance Control Algorithm in Three-phase Inverter Power
机车电传动
inverter power
nonlinear loads
quasi-proportional resonance
harmonic suppression
simulation
title Application of Quasi Proportional Resonance Control Algorithm in Three-phase Inverter Power
title_full Application of Quasi Proportional Resonance Control Algorithm in Three-phase Inverter Power
title_fullStr Application of Quasi Proportional Resonance Control Algorithm in Three-phase Inverter Power
title_full_unstemmed Application of Quasi Proportional Resonance Control Algorithm in Three-phase Inverter Power
title_short Application of Quasi Proportional Resonance Control Algorithm in Three-phase Inverter Power
title_sort application of quasi proportional resonance control algorithm in three phase inverter power
topic inverter power
nonlinear loads
quasi-proportional resonance
harmonic suppression
simulation
url http://edl.csrzic.com/thesisDetails#10.13890/j.issn.1000-128x.2020.02.012
work_keys_str_mv AT weiweigan applicationofquasiproportionalresonancecontrolalgorithminthreephaseinverterpower
AT weiguo applicationofquasiproportionalresonancecontrolalgorithminthreephaseinverterpower
AT kechen applicationofquasiproportionalresonancecontrolalgorithminthreephaseinverterpower
AT wentaowang applicationofquasiproportionalresonancecontrolalgorithminthreephaseinverterpower
AT minggaozeng applicationofquasiproportionalresonancecontrolalgorithminthreephaseinverterpower
AT xuebiaopeng applicationofquasiproportionalresonancecontrolalgorithminthreephaseinverterpower