Thermal-accumulating panel for microclimate support in a room with radioelectronic equipment
In a number of applications the functioning of radio electronic equipment (REO) occurs in rooms located in hard-to-reach regions with climatic conditions that are characterized by significant air temperature fluctuations reaching tens of Celsius degrees. To compensate these fluctuations various micr...
Saved in:
| Main Author: | |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Politehperiodika
2017-06-01
|
| Series: | Tekhnologiya i Konstruirovanie v Elektronnoi Apparature |
| Subjects: | |
| Online Access: | https://tkea.com.ua/index.php/journal/article/view/203 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850037431870423040 |
|---|---|
| author | V. Ye. Trofimov |
| author_facet | V. Ye. Trofimov |
| author_sort | V. Ye. Trofimov |
| collection | DOAJ |
| description | In a number of applications the functioning of radio electronic equipment (REO) occurs in rooms located in hard-to-reach regions with climatic conditions that are characterized by significant air temperature fluctuations reaching tens of Celsius degrees. To compensate these fluctuations various microclimate control devices are used. Their common property is necessity to consume electric energy, amount of which in the specified conditions is sufficiently limited. In this regard, the actual task is to minimize energy costs to provide the microclimate REO, for example, by using devices that do not require electrical energy for their operation.
One of the opportunities for solving this problem is using of a thermal-accumulating panel (TAP). It is designed to compensate heat losses from the room with REO at night. The principle of the TAP is based on the absorption and conservation of thermal energy for a period of time during the phase transition of a solid working substance into liquid influenced, for example, by solar radiation.
The construction of such TAP is considered here. Assessments of its operability, characteristics and recommendations for use are given. It is shown that at air temperature of 20 ... 25 С TAP can heat the room for at least 4.6 ... 6.2 hours at 2.5 ... 4.5 hours of sunny weather during daylight hours. |
| format | Article |
| id | doaj-art-bc7fb8fb04044a45a5df4abc03b6d55a |
| institution | DOAJ |
| issn | 2225-5818 2309-9992 |
| language | English |
| publishDate | 2017-06-01 |
| publisher | Politehperiodika |
| record_format | Article |
| series | Tekhnologiya i Konstruirovanie v Elektronnoi Apparature |
| spelling | doaj-art-bc7fb8fb04044a45a5df4abc03b6d55a2025-08-20T02:56:51ZengPolitehperiodikaTekhnologiya i Konstruirovanie v Elektronnoi Apparature2225-58182309-99922017-06-013363910.15222/TKEA2017.3.36203Thermal-accumulating panel for microclimate support in a room with radioelectronic equipmentV. Ye. Trofimov0Odessa National Polytechnic University, Odesа, UkraineIn a number of applications the functioning of radio electronic equipment (REO) occurs in rooms located in hard-to-reach regions with climatic conditions that are characterized by significant air temperature fluctuations reaching tens of Celsius degrees. To compensate these fluctuations various microclimate control devices are used. Their common property is necessity to consume electric energy, amount of which in the specified conditions is sufficiently limited. In this regard, the actual task is to minimize energy costs to provide the microclimate REO, for example, by using devices that do not require electrical energy for their operation. One of the opportunities for solving this problem is using of a thermal-accumulating panel (TAP). It is designed to compensate heat losses from the room with REO at night. The principle of the TAP is based on the absorption and conservation of thermal energy for a period of time during the phase transition of a solid working substance into liquid influenced, for example, by solar radiation. The construction of such TAP is considered here. Assessments of its operability, characteristics and recommendations for use are given. It is shown that at air temperature of 20 ... 25 С TAP can heat the room for at least 4.6 ... 6.2 hours at 2.5 ... 4.5 hours of sunny weather during daylight hours.https://tkea.com.ua/index.php/journal/article/view/203radio electronic equipmentmicroclimatesolar energy accumulatormelting substances |
| spellingShingle | V. Ye. Trofimov Thermal-accumulating panel for microclimate support in a room with radioelectronic equipment Tekhnologiya i Konstruirovanie v Elektronnoi Apparature radio electronic equipment microclimate solar energy accumulator melting substances |
| title | Thermal-accumulating panel for microclimate support in a room with radioelectronic equipment |
| title_full | Thermal-accumulating panel for microclimate support in a room with radioelectronic equipment |
| title_fullStr | Thermal-accumulating panel for microclimate support in a room with radioelectronic equipment |
| title_full_unstemmed | Thermal-accumulating panel for microclimate support in a room with radioelectronic equipment |
| title_short | Thermal-accumulating panel for microclimate support in a room with radioelectronic equipment |
| title_sort | thermal accumulating panel for microclimate support in a room with radioelectronic equipment |
| topic | radio electronic equipment microclimate solar energy accumulator melting substances |
| url | https://tkea.com.ua/index.php/journal/article/view/203 |
| work_keys_str_mv | AT vyetrofimov thermalaccumulatingpanelformicroclimatesupportinaroomwithradioelectronicequipment |