Influence of air flow interruption on the total nonelastic resistance of respiration

The total nonelastic work of respiration (TNWR) was studied in 18 healthy people and 11 patients with the chronic obstructive pulmonary disease with the aid of simultaneous recording of transpulmonary pressure and volume. It was found that under the conditions of identical pulmonary minute volume at...

Full description

Saved in:
Bibliographic Details
Main Author: T. N. Bodrova
Format: Article
Language:English
Published: Siberian State Medical University (Tomsk) 2011-12-01
Series:Бюллетень сибирской медицины
Subjects:
Online Access:https://bulletin.ssmu.ru/jour/article/view/1517
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849689150613094400
author T. N. Bodrova
author_facet T. N. Bodrova
author_sort T. N. Bodrova
collection DOAJ
description The total nonelastic work of respiration (TNWR) was studied in 18 healthy people and 11 patients with the chronic obstructive pulmonary disease with the aid of simultaneous recording of transpulmonary pressure and volume. It was found that under the conditions of identical pulmonary minute volume at air flow interruption by valve, TNWR becomes larger compared to that at quiet deep breathing. The additional resistance was called acophased and was considered as a manifestation of independent mechanical pulmonary activity.
format Article
id doaj-art-bbcfb9eb579b4d0485043bb9770026b8
institution DOAJ
issn 1682-0363
1819-3684
language English
publishDate 2011-12-01
publisher Siberian State Medical University (Tomsk)
record_format Article
series Бюллетень сибирской медицины
spelling doaj-art-bbcfb9eb579b4d0485043bb9770026b82025-08-20T03:21:44ZengSiberian State Medical University (Tomsk)Бюллетень сибирской медицины1682-03631819-36842011-12-0110614915110.20538/1682-0363-2011-6-149-1511023Influence of air flow interruption on the total nonelastic resistance of respirationT. N. Bodrova0Сибирский государственный медицинский университетThe total nonelastic work of respiration (TNWR) was studied in 18 healthy people and 11 patients with the chronic obstructive pulmonary disease with the aid of simultaneous recording of transpulmonary pressure and volume. It was found that under the conditions of identical pulmonary minute volume at air flow interruption by valve, TNWR becomes larger compared to that at quiet deep breathing. The additional resistance was called acophased and was considered as a manifestation of independent mechanical pulmonary activity.https://bulletin.ssmu.ru/jour/article/view/1517total nonelastic work of respirationacophased resistancemechanical pulmonary activity
spellingShingle T. N. Bodrova
Influence of air flow interruption on the total nonelastic resistance of respiration
Бюллетень сибирской медицины
total nonelastic work of respiration
acophased resistance
mechanical pulmonary activity
title Influence of air flow interruption on the total nonelastic resistance of respiration
title_full Influence of air flow interruption on the total nonelastic resistance of respiration
title_fullStr Influence of air flow interruption on the total nonelastic resistance of respiration
title_full_unstemmed Influence of air flow interruption on the total nonelastic resistance of respiration
title_short Influence of air flow interruption on the total nonelastic resistance of respiration
title_sort influence of air flow interruption on the total nonelastic resistance of respiration
topic total nonelastic work of respiration
acophased resistance
mechanical pulmonary activity
url https://bulletin.ssmu.ru/jour/article/view/1517
work_keys_str_mv AT tnbodrova influenceofairflowinterruptiononthetotalnonelasticresistanceofrespiration