Mitigation methods and their applicability for DC stray current interference

Through indoor simulated experimental equipment,mitigation methods which contained the bond resistor method,galvanic anode method and metallic shield method were studied to mitigate DC stray current interference caused by the impressed current cathodic protection system on pipelines without cathodic...

Full description

Saved in:
Bibliographic Details
Main Authors: LI Wei, DU Yan-xia, WANG Jie-jun
Format: Article
Language:zho
Published: Science Press 2016-07-01
Series:工程科学学报
Subjects:
Online Access:http://cje.ustb.edu.cn/article/doi/10.13374/j.issn2095-9389.2016.07.010
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850282887701594112
author LI Wei
DU Yan-xia
WANG Jie-jun
author_facet LI Wei
DU Yan-xia
WANG Jie-jun
author_sort LI Wei
collection DOAJ
description Through indoor simulated experimental equipment,mitigation methods which contained the bond resistor method,galvanic anode method and metallic shield method were studied to mitigate DC stray current interference caused by the impressed current cathodic protection system on pipelines without cathodic protection at the external. The influences of bond resistance,galvanic anode location and materials,metallic shield location and connecting methods on the mitigation and regularity for different types of interference were investigated,and the applicability for different mitigation methods was also analyzed. In addition,it can also provide reference for practical engineering with putting forward recommendations and application conditions for different types of interference.
format Article
id doaj-art-bbb659a1d3fc4cedb55892ef21e6f414
institution OA Journals
issn 2095-9389
language zho
publishDate 2016-07-01
publisher Science Press
record_format Article
series 工程科学学报
spelling doaj-art-bbb659a1d3fc4cedb55892ef21e6f4142025-08-20T01:47:51ZzhoScience Press工程科学学报2095-93892016-07-0138795896610.13374/j.issn2095-9389.2016.07.010Mitigation methods and their applicability for DC stray current interferenceLI Wei0DU Yan-xia1WANG Jie-jun2Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, ChinaInstitute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, ChinaInstitute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, ChinaThrough indoor simulated experimental equipment,mitigation methods which contained the bond resistor method,galvanic anode method and metallic shield method were studied to mitigate DC stray current interference caused by the impressed current cathodic protection system on pipelines without cathodic protection at the external. The influences of bond resistance,galvanic anode location and materials,metallic shield location and connecting methods on the mitigation and regularity for different types of interference were investigated,and the applicability for different mitigation methods was also analyzed. In addition,it can also provide reference for practical engineering with putting forward recommendations and application conditions for different types of interference.http://cje.ustb.edu.cn/article/doi/10.13374/j.issn2095-9389.2016.07.010buried pipelinescathodic protectionstray currentcorrosion inhibition
spellingShingle LI Wei
DU Yan-xia
WANG Jie-jun
Mitigation methods and their applicability for DC stray current interference
工程科学学报
buried pipelines
cathodic protection
stray current
corrosion inhibition
title Mitigation methods and their applicability for DC stray current interference
title_full Mitigation methods and their applicability for DC stray current interference
title_fullStr Mitigation methods and their applicability for DC stray current interference
title_full_unstemmed Mitigation methods and their applicability for DC stray current interference
title_short Mitigation methods and their applicability for DC stray current interference
title_sort mitigation methods and their applicability for dc stray current interference
topic buried pipelines
cathodic protection
stray current
corrosion inhibition
url http://cje.ustb.edu.cn/article/doi/10.13374/j.issn2095-9389.2016.07.010
work_keys_str_mv AT liwei mitigationmethodsandtheirapplicabilityfordcstraycurrentinterference
AT duyanxia mitigationmethodsandtheirapplicabilityfordcstraycurrentinterference
AT wangjiejun mitigationmethodsandtheirapplicabilityfordcstraycurrentinterference