Short-Circuit Protection Schemes for LVDC Microgrids Based on the Combination of Hybrid Circuit Breakers and Mechanical Breakers

In recent years, low-voltage direct current (LVDC) microgrids are becoming more attractive because they represent a solution to integrate renewable sources, storage, and electronic loads bringing some advantages in comparison with traditional AC grids. However, the protection of such a network invol...

Full description

Saved in:
Bibliographic Details
Main Authors: Riccardo Lazzari, Luigi Piegari
Format: Article
Language:English
Published: Wiley 2023-01-01
Series:International Transactions on Electrical Energy Systems
Online Access:http://dx.doi.org/10.1155/2023/9403058
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849766279158693888
author Riccardo Lazzari
Luigi Piegari
author_facet Riccardo Lazzari
Luigi Piegari
author_sort Riccardo Lazzari
collection DOAJ
description In recent years, low-voltage direct current (LVDC) microgrids are becoming more attractive because they represent a solution to integrate renewable sources, storage, and electronic loads bringing some advantages in comparison with traditional AC grids. However, the protection of such a network involves many challenges, especially in the case of LVDC microgrids with more than one feeder and multiple energy sources. Indeed, the traditional protection breakers used for an AC grid cannot isolate the faults and protect the components of a DC grid, while the use of solid-state circuit breakers increases energy losses. This paper deals with the analysis and design of the protection schemes for LVDC microgrids through the combination of mechanical circuit breakers and hybrid circuit breakers. This solution has the advantage of energy loss reduction but introduces further issues due to the slow transition times of the mechanical circuit breakers. Thus, a completely decentralized control system capable of overcoming the fast fault-clearing time, cost-effectiveness, and selectivity issues is designed to protect from pole-to-pole faults. The proposed control strategy is compared with a centralized protection scheme available in the literature through numerical simulation. The two algorithms show similar performances, with a mean voltage dip duration of less than 30 ms and a maximum voltage dip duration of about 100 ms in the most severe fault condition, but the proposed solution is more reliable and flexible since it does not depend on the communication system.
format Article
id doaj-art-bb53b82d1d784659b4ddedfee8a85489
institution DOAJ
issn 2050-7038
language English
publishDate 2023-01-01
publisher Wiley
record_format Article
series International Transactions on Electrical Energy Systems
spelling doaj-art-bb53b82d1d784659b4ddedfee8a854892025-08-20T03:04:38ZengWileyInternational Transactions on Electrical Energy Systems2050-70382023-01-01202310.1155/2023/9403058Short-Circuit Protection Schemes for LVDC Microgrids Based on the Combination of Hybrid Circuit Breakers and Mechanical BreakersRiccardo Lazzari0Luigi Piegari1Materials and Generation Technologies DepartmentDipartimento di ElettronicaIn recent years, low-voltage direct current (LVDC) microgrids are becoming more attractive because they represent a solution to integrate renewable sources, storage, and electronic loads bringing some advantages in comparison with traditional AC grids. However, the protection of such a network involves many challenges, especially in the case of LVDC microgrids with more than one feeder and multiple energy sources. Indeed, the traditional protection breakers used for an AC grid cannot isolate the faults and protect the components of a DC grid, while the use of solid-state circuit breakers increases energy losses. This paper deals with the analysis and design of the protection schemes for LVDC microgrids through the combination of mechanical circuit breakers and hybrid circuit breakers. This solution has the advantage of energy loss reduction but introduces further issues due to the slow transition times of the mechanical circuit breakers. Thus, a completely decentralized control system capable of overcoming the fast fault-clearing time, cost-effectiveness, and selectivity issues is designed to protect from pole-to-pole faults. The proposed control strategy is compared with a centralized protection scheme available in the literature through numerical simulation. The two algorithms show similar performances, with a mean voltage dip duration of less than 30 ms and a maximum voltage dip duration of about 100 ms in the most severe fault condition, but the proposed solution is more reliable and flexible since it does not depend on the communication system.http://dx.doi.org/10.1155/2023/9403058
spellingShingle Riccardo Lazzari
Luigi Piegari
Short-Circuit Protection Schemes for LVDC Microgrids Based on the Combination of Hybrid Circuit Breakers and Mechanical Breakers
International Transactions on Electrical Energy Systems
title Short-Circuit Protection Schemes for LVDC Microgrids Based on the Combination of Hybrid Circuit Breakers and Mechanical Breakers
title_full Short-Circuit Protection Schemes for LVDC Microgrids Based on the Combination of Hybrid Circuit Breakers and Mechanical Breakers
title_fullStr Short-Circuit Protection Schemes for LVDC Microgrids Based on the Combination of Hybrid Circuit Breakers and Mechanical Breakers
title_full_unstemmed Short-Circuit Protection Schemes for LVDC Microgrids Based on the Combination of Hybrid Circuit Breakers and Mechanical Breakers
title_short Short-Circuit Protection Schemes for LVDC Microgrids Based on the Combination of Hybrid Circuit Breakers and Mechanical Breakers
title_sort short circuit protection schemes for lvdc microgrids based on the combination of hybrid circuit breakers and mechanical breakers
url http://dx.doi.org/10.1155/2023/9403058
work_keys_str_mv AT riccardolazzari shortcircuitprotectionschemesforlvdcmicrogridsbasedonthecombinationofhybridcircuitbreakersandmechanicalbreakers
AT luigipiegari shortcircuitprotectionschemesforlvdcmicrogridsbasedonthecombinationofhybridcircuitbreakersandmechanicalbreakers