Experimental Study on the Influence of the Water Temperature to the Performance of CO2 Heat Pump Water Heater
The performance of CO2 heat pump water heater was studied experimentally in this paper by comparing a loop heating and a direct heating hot water. In the loop heating mode, with an increase of the water temperature, the compressor inlet and exhaust pressure increased gradually, the power consumption...
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Journal of Refrigeration Magazines Agency Co., Ltd.
2012-01-01
|
| Series: | Zhileng xuebao |
| Subjects: | |
| Online Access: | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2012.06.073 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850232933210652672 |
|---|---|
| author | Lv Jing Ren Yingying Yang Jie Dou Junjun Hu Tete |
| author_facet | Lv Jing Ren Yingying Yang Jie Dou Junjun Hu Tete |
| author_sort | Lv Jing |
| collection | DOAJ |
| description | The performance of CO2 heat pump water heater was studied experimentally in this paper by comparing a loop heating and a direct heating hot water. In the loop heating mode, with an increase of the water temperature, the compressor inlet and exhaust pressure increased gradually, the power consumption increased and the gas cooler inlet and outlet temperature increased, too. The temperature difference between carbon dioxide and cooling water and heat transfer decreased, the COP of CO2 heat pump system decreased. The operating parameters of the system were stable and the COP remained unchanged in direct heated condition. When the water temperature is 17℃, the COP of the system is about 3.5, much higher than that in loop heating. The results show that the lower inlet temperature can be obtained by modifying the water tank structure and it is a very effective way to improve system performance. |
| format | Article |
| id | doaj-art-baeef150087c4a22a8c1ad91ea46b9b4 |
| institution | OA Journals |
| issn | 0253-4339 |
| language | zho |
| publishDate | 2012-01-01 |
| publisher | Journal of Refrigeration Magazines Agency Co., Ltd. |
| record_format | Article |
| series | Zhileng xuebao |
| spelling | doaj-art-baeef150087c4a22a8c1ad91ea46b9b42025-08-20T02:03:01ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392012-01-013366518055Experimental Study on the Influence of the Water Temperature to the Performance of CO2 Heat Pump Water HeaterLv JingRen YingyingYang JieDou JunjunHu TeteThe performance of CO2 heat pump water heater was studied experimentally in this paper by comparing a loop heating and a direct heating hot water. In the loop heating mode, with an increase of the water temperature, the compressor inlet and exhaust pressure increased gradually, the power consumption increased and the gas cooler inlet and outlet temperature increased, too. The temperature difference between carbon dioxide and cooling water and heat transfer decreased, the COP of CO2 heat pump system decreased. The operating parameters of the system were stable and the COP remained unchanged in direct heated condition. When the water temperature is 17℃, the COP of the system is about 3.5, much higher than that in loop heating. The results show that the lower inlet temperature can be obtained by modifying the water tank structure and it is a very effective way to improve system performance.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2012.06.073pyrologyCO2 heat pump water heaterloop heating modedirected heated conditionwater tank temperatureCOP |
| spellingShingle | Lv Jing Ren Yingying Yang Jie Dou Junjun Hu Tete Experimental Study on the Influence of the Water Temperature to the Performance of CO2 Heat Pump Water Heater Zhileng xuebao pyrology CO2 heat pump water heater loop heating mode directed heated condition water tank temperature COP |
| title | Experimental Study on the Influence of the Water Temperature to the Performance of CO2 Heat Pump Water Heater |
| title_full | Experimental Study on the Influence of the Water Temperature to the Performance of CO2 Heat Pump Water Heater |
| title_fullStr | Experimental Study on the Influence of the Water Temperature to the Performance of CO2 Heat Pump Water Heater |
| title_full_unstemmed | Experimental Study on the Influence of the Water Temperature to the Performance of CO2 Heat Pump Water Heater |
| title_short | Experimental Study on the Influence of the Water Temperature to the Performance of CO2 Heat Pump Water Heater |
| title_sort | experimental study on the influence of the water temperature to the performance of co2 heat pump water heater |
| topic | pyrology CO2 heat pump water heater loop heating mode directed heated condition water tank temperature COP |
| url | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2012.06.073 |
| work_keys_str_mv | AT lvjing experimentalstudyontheinfluenceofthewatertemperaturetotheperformanceofco2heatpumpwaterheater AT renyingying experimentalstudyontheinfluenceofthewatertemperaturetotheperformanceofco2heatpumpwaterheater AT yangjie experimentalstudyontheinfluenceofthewatertemperaturetotheperformanceofco2heatpumpwaterheater AT doujunjun experimentalstudyontheinfluenceofthewatertemperaturetotheperformanceofco2heatpumpwaterheater AT hutete experimentalstudyontheinfluenceofthewatertemperaturetotheperformanceofco2heatpumpwaterheater |