Experimental Study on the Influence of the Water Temperature to the Performance of CO2 Heat Pump Water Heater

The performance of CO2 heat pump water heater was studied experimentally in this paper by comparing a loop heating and a direct heating hot water. In the loop heating mode, with an increase of the water temperature, the compressor inlet and exhaust pressure increased gradually, the power consumption...

Full description

Saved in:
Bibliographic Details
Main Authors: Lv Jing, Ren Yingying, Yang Jie, Dou Junjun, Hu Tete
Format: Article
Language:zho
Published: Journal of Refrigeration Magazines Agency Co., Ltd. 2012-01-01
Series:Zhileng xuebao
Subjects:
Online Access:http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2012.06.073
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850232933210652672
author Lv Jing
Ren Yingying
Yang Jie
Dou Junjun
Hu Tete
author_facet Lv Jing
Ren Yingying
Yang Jie
Dou Junjun
Hu Tete
author_sort Lv Jing
collection DOAJ
description The performance of CO2 heat pump water heater was studied experimentally in this paper by comparing a loop heating and a direct heating hot water. In the loop heating mode, with an increase of the water temperature, the compressor inlet and exhaust pressure increased gradually, the power consumption increased and the gas cooler inlet and outlet temperature increased, too. The temperature difference between carbon dioxide and cooling water and heat transfer decreased, the COP of CO2 heat pump system decreased. The operating parameters of the system were stable and the COP remained unchanged in direct heated condition. When the water temperature is 17℃, the COP of the system is about 3.5, much higher than that in loop heating. The results show that the lower inlet temperature can be obtained by modifying the water tank structure and it is a very effective way to improve system performance.
format Article
id doaj-art-baeef150087c4a22a8c1ad91ea46b9b4
institution OA Journals
issn 0253-4339
language zho
publishDate 2012-01-01
publisher Journal of Refrigeration Magazines Agency Co., Ltd.
record_format Article
series Zhileng xuebao
spelling doaj-art-baeef150087c4a22a8c1ad91ea46b9b42025-08-20T02:03:01ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392012-01-013366518055Experimental Study on the Influence of the Water Temperature to the Performance of CO2 Heat Pump Water HeaterLv JingRen YingyingYang JieDou JunjunHu TeteThe performance of CO2 heat pump water heater was studied experimentally in this paper by comparing a loop heating and a direct heating hot water. In the loop heating mode, with an increase of the water temperature, the compressor inlet and exhaust pressure increased gradually, the power consumption increased and the gas cooler inlet and outlet temperature increased, too. The temperature difference between carbon dioxide and cooling water and heat transfer decreased, the COP of CO2 heat pump system decreased. The operating parameters of the system were stable and the COP remained unchanged in direct heated condition. When the water temperature is 17℃, the COP of the system is about 3.5, much higher than that in loop heating. The results show that the lower inlet temperature can be obtained by modifying the water tank structure and it is a very effective way to improve system performance.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2012.06.073pyrologyCO2 heat pump water heaterloop heating modedirected heated conditionwater tank temperatureCOP
spellingShingle Lv Jing
Ren Yingying
Yang Jie
Dou Junjun
Hu Tete
Experimental Study on the Influence of the Water Temperature to the Performance of CO2 Heat Pump Water Heater
Zhileng xuebao
pyrology
CO2 heat pump water heater
loop heating mode
directed heated condition
water tank temperature
COP
title Experimental Study on the Influence of the Water Temperature to the Performance of CO2 Heat Pump Water Heater
title_full Experimental Study on the Influence of the Water Temperature to the Performance of CO2 Heat Pump Water Heater
title_fullStr Experimental Study on the Influence of the Water Temperature to the Performance of CO2 Heat Pump Water Heater
title_full_unstemmed Experimental Study on the Influence of the Water Temperature to the Performance of CO2 Heat Pump Water Heater
title_short Experimental Study on the Influence of the Water Temperature to the Performance of CO2 Heat Pump Water Heater
title_sort experimental study on the influence of the water temperature to the performance of co2 heat pump water heater
topic pyrology
CO2 heat pump water heater
loop heating mode
directed heated condition
water tank temperature
COP
url http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2012.06.073
work_keys_str_mv AT lvjing experimentalstudyontheinfluenceofthewatertemperaturetotheperformanceofco2heatpumpwaterheater
AT renyingying experimentalstudyontheinfluenceofthewatertemperaturetotheperformanceofco2heatpumpwaterheater
AT yangjie experimentalstudyontheinfluenceofthewatertemperaturetotheperformanceofco2heatpumpwaterheater
AT doujunjun experimentalstudyontheinfluenceofthewatertemperaturetotheperformanceofco2heatpumpwaterheater
AT hutete experimentalstudyontheinfluenceofthewatertemperaturetotheperformanceofco2heatpumpwaterheater