PENGARUH PASANGAN DINDING BATA PADA RESPON DINAMIK STRUKTUR GEDUNG AKIBAT BEBAN GEMPA

For analysis purpose, the model system of structure is created as open frame structure rather than massive structure. However, the brick wall will affect to the behavior of the dynamic response when the earthquake induces the structure. The results of structural analysis by time history method using...

Full description

Saved in:
Bibliographic Details
Main Authors: Himawan Indarto, Bambang Pardoyo, Nur Fahria R, Ita Puji L
Format: Article
Language:English
Published: Universitas Negeri Semarang 2016-01-01
Series:Jurnal Teknik Sipil dan Perencanaan
Subjects:
Online Access:https://journal.unnes.ac.id/nju/index.php/jtsp/article/view/6689
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850234121070051328
author Himawan Indarto
Bambang Pardoyo
Nur Fahria R
Ita Puji L
author_facet Himawan Indarto
Bambang Pardoyo
Nur Fahria R
Ita Puji L
author_sort Himawan Indarto
collection DOAJ
description For analysis purpose, the model system of structure is created as open frame structure rather than massive structure. However, the brick wall will affect to the behavior of the dynamic response when the earthquake induces the structure. The results of structural analysis by time history method using El-Centro earthquake, it reveales a significant difference of base shear between two types of structural model: (i) brick wall structure and (ii) non-brick wall structure. The base shear exists on the brick wall structure 20 percent greater than non-brick wall structure. Therefore, a structure without brick wall will be more irressistant due to the earthquake. The structural analysis using static equivalent method as point out in Standard of Earthquake Resistant for Building and Non Building (SNI 03-1726-2012) revealed that earthquake distribution loads relatively equal for brick wall structure and non-brick wall structure. The difference of earthquake load approximately 10 percent among two type of structure. Thus, it could be concluded that static equivalent method is more reliable to estimate the earthquake load of the structure rather than other method. This research suggests that in the structural design practicality, the effect of brick wall should be considered as a part of the structural analysis model.
format Article
id doaj-art-bab45811233a4dfe8c586ee052d78160
institution OA Journals
issn 1411-1772
2503-1899
language English
publishDate 2016-01-01
publisher Universitas Negeri Semarang
record_format Article
series Jurnal Teknik Sipil dan Perencanaan
spelling doaj-art-bab45811233a4dfe8c586ee052d781602025-08-20T02:02:43ZengUniversitas Negeri SemarangJurnal Teknik Sipil dan Perencanaan1411-17722503-18992016-01-01181914PENGARUH PASANGAN DINDING BATA PADA RESPON DINAMIK STRUKTUR GEDUNG AKIBAT BEBAN GEMPAHimawan Indarto0 Bambang Pardoyo1Nur Fahria R2Ita Puji L3Universitas DiponegoroUniversitas DiponegoroUniversitas DiponegoroUniversitas DiponegoroFor analysis purpose, the model system of structure is created as open frame structure rather than massive structure. However, the brick wall will affect to the behavior of the dynamic response when the earthquake induces the structure. The results of structural analysis by time history method using El-Centro earthquake, it reveales a significant difference of base shear between two types of structural model: (i) brick wall structure and (ii) non-brick wall structure. The base shear exists on the brick wall structure 20 percent greater than non-brick wall structure. Therefore, a structure without brick wall will be more irressistant due to the earthquake. The structural analysis using static equivalent method as point out in Standard of Earthquake Resistant for Building and Non Building (SNI 03-1726-2012) revealed that earthquake distribution loads relatively equal for brick wall structure and non-brick wall structure. The difference of earthquake load approximately 10 percent among two type of structure. Thus, it could be concluded that static equivalent method is more reliable to estimate the earthquake load of the structure rather than other method. This research suggests that in the structural design practicality, the effect of brick wall should be considered as a part of the structural analysis model.https://journal.unnes.ac.id/nju/index.php/jtsp/article/view/6689brick walltime history analysisbase shear
spellingShingle Himawan Indarto
Bambang Pardoyo
Nur Fahria R
Ita Puji L
PENGARUH PASANGAN DINDING BATA PADA RESPON DINAMIK STRUKTUR GEDUNG AKIBAT BEBAN GEMPA
Jurnal Teknik Sipil dan Perencanaan
brick wall
time history analysis
base shear
title PENGARUH PASANGAN DINDING BATA PADA RESPON DINAMIK STRUKTUR GEDUNG AKIBAT BEBAN GEMPA
title_full PENGARUH PASANGAN DINDING BATA PADA RESPON DINAMIK STRUKTUR GEDUNG AKIBAT BEBAN GEMPA
title_fullStr PENGARUH PASANGAN DINDING BATA PADA RESPON DINAMIK STRUKTUR GEDUNG AKIBAT BEBAN GEMPA
title_full_unstemmed PENGARUH PASANGAN DINDING BATA PADA RESPON DINAMIK STRUKTUR GEDUNG AKIBAT BEBAN GEMPA
title_short PENGARUH PASANGAN DINDING BATA PADA RESPON DINAMIK STRUKTUR GEDUNG AKIBAT BEBAN GEMPA
title_sort pengaruh pasangan dinding bata pada respon dinamik struktur gedung akibat beban gempa
topic brick wall
time history analysis
base shear
url https://journal.unnes.ac.id/nju/index.php/jtsp/article/view/6689
work_keys_str_mv AT himawanindarto pengaruhpasangandindingbatapadarespondinamikstrukturgedungakibatbebangempa
AT bambangpardoyo pengaruhpasangandindingbatapadarespondinamikstrukturgedungakibatbebangempa
AT nurfahriar pengaruhpasangandindingbatapadarespondinamikstrukturgedungakibatbebangempa
AT itapujil pengaruhpasangandindingbatapadarespondinamikstrukturgedungakibatbebangempa