Internal Fixation for Unstable Distal Ulnar Fractures by 2.7 mm Semitubular Hook Plate
Conclusion: Using the 2.7 mm semitubular hook plate is a successful choice for internal fixation of unstable distal ulnar fractures isolated or associated with distal radius fractures with a favorable union time, functional outcome, and range of motion with minimal complications.
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2024-01-01
|
Series: | Advances in Orthopedics |
Online Access: | http://dx.doi.org/10.1155/aort/5663025 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1846099194862895104 |
---|---|
author | Mohamed I. Abulsoud Mohammed Elmarghany Ahmed R. Zakaria Ehab A. Alshal Mohamed Moawad Ehab A. Elzahed Mohamed F. Elhalawany Bahaa A. Kornah |
author_facet | Mohamed I. Abulsoud Mohammed Elmarghany Ahmed R. Zakaria Ehab A. Alshal Mohamed Moawad Ehab A. Elzahed Mohamed F. Elhalawany Bahaa A. Kornah |
author_sort | Mohamed I. Abulsoud |
collection | DOAJ |
description | Conclusion: Using the 2.7 mm semitubular hook plate is a successful choice for internal fixation of unstable distal ulnar fractures isolated or associated with distal radius fractures with a favorable union time, functional outcome, and range of motion with minimal complications. |
format | Article |
id | doaj-art-ba8baf77a17c4db1850718c64fffc90e |
institution | Kabale University |
issn | 2090-3472 |
language | English |
publishDate | 2024-01-01 |
publisher | Wiley |
record_format | Article |
series | Advances in Orthopedics |
spelling | doaj-art-ba8baf77a17c4db1850718c64fffc90e2025-01-01T00:00:03ZengWileyAdvances in Orthopedics2090-34722024-01-01202410.1155/aort/5663025Internal Fixation for Unstable Distal Ulnar Fractures by 2.7 mm Semitubular Hook PlateMohamed I. Abulsoud0Mohammed Elmarghany1Ahmed R. Zakaria2Ehab A. Alshal3Mohamed Moawad4Ehab A. Elzahed5Mohamed F. Elhalawany6Bahaa A. Kornah7Department of Orthopedic SurgeryDepartment of Orthopedic SurgeryDepartment of Orthopedic SurgeryDepartment of Orthopedic SurgeryDepartment of Orthopedic SurgeryDepartment of Orthopedic SurgeryDepartment of Orthopedic SurgeryDepartment of Orthopedic SurgeryConclusion: Using the 2.7 mm semitubular hook plate is a successful choice for internal fixation of unstable distal ulnar fractures isolated or associated with distal radius fractures with a favorable union time, functional outcome, and range of motion with minimal complications.http://dx.doi.org/10.1155/aort/5663025 |
spellingShingle | Mohamed I. Abulsoud Mohammed Elmarghany Ahmed R. Zakaria Ehab A. Alshal Mohamed Moawad Ehab A. Elzahed Mohamed F. Elhalawany Bahaa A. Kornah Internal Fixation for Unstable Distal Ulnar Fractures by 2.7 mm Semitubular Hook Plate Advances in Orthopedics |
title | Internal Fixation for Unstable Distal Ulnar Fractures by 2.7 mm Semitubular Hook Plate |
title_full | Internal Fixation for Unstable Distal Ulnar Fractures by 2.7 mm Semitubular Hook Plate |
title_fullStr | Internal Fixation for Unstable Distal Ulnar Fractures by 2.7 mm Semitubular Hook Plate |
title_full_unstemmed | Internal Fixation for Unstable Distal Ulnar Fractures by 2.7 mm Semitubular Hook Plate |
title_short | Internal Fixation for Unstable Distal Ulnar Fractures by 2.7 mm Semitubular Hook Plate |
title_sort | internal fixation for unstable distal ulnar fractures by 2 7 mm semitubular hook plate |
url | http://dx.doi.org/10.1155/aort/5663025 |
work_keys_str_mv | AT mohamediabulsoud internalfixationforunstabledistalulnarfracturesby27mmsemitubularhookplate AT mohammedelmarghany internalfixationforunstabledistalulnarfracturesby27mmsemitubularhookplate AT ahmedrzakaria internalfixationforunstabledistalulnarfracturesby27mmsemitubularhookplate AT ehabaalshal internalfixationforunstabledistalulnarfracturesby27mmsemitubularhookplate AT mohamedmoawad internalfixationforunstabledistalulnarfracturesby27mmsemitubularhookplate AT ehabaelzahed internalfixationforunstabledistalulnarfracturesby27mmsemitubularhookplate AT mohamedfelhalawany internalfixationforunstabledistalulnarfracturesby27mmsemitubularhookplate AT bahaaakornah internalfixationforunstabledistalulnarfracturesby27mmsemitubularhookplate |