Electromagnetic Interference from Left Ventricular Assist Device (LVAD) Inhibiting the Pacing Function of an Implantable Cardioverter-Defibrillator (ICD) Device
There is an increasing prevalence of patients with concomitant implantable cardioverter-defibrillators (ICDs) and left ventricular devices (LVADs). The potential for negative interactions between these continually evolving technologies is a valid concern. Previously reported interactions include ina...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2018-01-01
|
Series: | Case Reports in Cardiology |
Online Access: | http://dx.doi.org/10.1155/2018/6195045 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832561313359855616 |
---|---|
author | Sebhat Erqou Robert L. Kormos Norman C. Wang Dennis M. McNamara Raveen Bazaz |
author_facet | Sebhat Erqou Robert L. Kormos Norman C. Wang Dennis M. McNamara Raveen Bazaz |
author_sort | Sebhat Erqou |
collection | DOAJ |
description | There is an increasing prevalence of patients with concomitant implantable cardioverter-defibrillators (ICDs) and left ventricular devices (LVADs). The potential for negative interactions between these continually evolving technologies is a valid concern. Previously reported interactions include inappropriate ICD therapy and interference with ICD telemetry function. Understanding the nature of such interactions and developing a comprehensive strategy to approach such situations are important. In this report, we describe a case of electromagnetic interference from LVAD inhibiting the pacing function of an ICD that was corrected by reprograming the device. We would encourage investigators to review patients with ICD and LVAD in their institutions in order to help assess the frequency and nature of these and other interactions. |
format | Article |
id | doaj-art-b9e7a4573c50480ba20c1b57899d18a9 |
institution | Kabale University |
issn | 2090-6404 2090-6412 |
language | English |
publishDate | 2018-01-01 |
publisher | Wiley |
record_format | Article |
series | Case Reports in Cardiology |
spelling | doaj-art-b9e7a4573c50480ba20c1b57899d18a92025-02-03T01:25:22ZengWileyCase Reports in Cardiology2090-64042090-64122018-01-01201810.1155/2018/61950456195045Electromagnetic Interference from Left Ventricular Assist Device (LVAD) Inhibiting the Pacing Function of an Implantable Cardioverter-Defibrillator (ICD) DeviceSebhat Erqou0Robert L. Kormos1Norman C. Wang2Dennis M. McNamara3Raveen Bazaz4Department of Medicine, Alpert Medical School of Brown University, Providence, RI, USAHeart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, PA, USAHeart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, PA, USAHeart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, PA, USAHeart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, PA, USAThere is an increasing prevalence of patients with concomitant implantable cardioverter-defibrillators (ICDs) and left ventricular devices (LVADs). The potential for negative interactions between these continually evolving technologies is a valid concern. Previously reported interactions include inappropriate ICD therapy and interference with ICD telemetry function. Understanding the nature of such interactions and developing a comprehensive strategy to approach such situations are important. In this report, we describe a case of electromagnetic interference from LVAD inhibiting the pacing function of an ICD that was corrected by reprograming the device. We would encourage investigators to review patients with ICD and LVAD in their institutions in order to help assess the frequency and nature of these and other interactions.http://dx.doi.org/10.1155/2018/6195045 |
spellingShingle | Sebhat Erqou Robert L. Kormos Norman C. Wang Dennis M. McNamara Raveen Bazaz Electromagnetic Interference from Left Ventricular Assist Device (LVAD) Inhibiting the Pacing Function of an Implantable Cardioverter-Defibrillator (ICD) Device Case Reports in Cardiology |
title | Electromagnetic Interference from Left Ventricular Assist Device (LVAD) Inhibiting the Pacing Function of an Implantable Cardioverter-Defibrillator (ICD) Device |
title_full | Electromagnetic Interference from Left Ventricular Assist Device (LVAD) Inhibiting the Pacing Function of an Implantable Cardioverter-Defibrillator (ICD) Device |
title_fullStr | Electromagnetic Interference from Left Ventricular Assist Device (LVAD) Inhibiting the Pacing Function of an Implantable Cardioverter-Defibrillator (ICD) Device |
title_full_unstemmed | Electromagnetic Interference from Left Ventricular Assist Device (LVAD) Inhibiting the Pacing Function of an Implantable Cardioverter-Defibrillator (ICD) Device |
title_short | Electromagnetic Interference from Left Ventricular Assist Device (LVAD) Inhibiting the Pacing Function of an Implantable Cardioverter-Defibrillator (ICD) Device |
title_sort | electromagnetic interference from left ventricular assist device lvad inhibiting the pacing function of an implantable cardioverter defibrillator icd device |
url | http://dx.doi.org/10.1155/2018/6195045 |
work_keys_str_mv | AT sebhaterqou electromagneticinterferencefromleftventricularassistdevicelvadinhibitingthepacingfunctionofanimplantablecardioverterdefibrillatoricddevice AT robertlkormos electromagneticinterferencefromleftventricularassistdevicelvadinhibitingthepacingfunctionofanimplantablecardioverterdefibrillatoricddevice AT normancwang electromagneticinterferencefromleftventricularassistdevicelvadinhibitingthepacingfunctionofanimplantablecardioverterdefibrillatoricddevice AT dennismmcnamara electromagneticinterferencefromleftventricularassistdevicelvadinhibitingthepacingfunctionofanimplantablecardioverterdefibrillatoricddevice AT raveenbazaz electromagneticinterferencefromleftventricularassistdevicelvadinhibitingthepacingfunctionofanimplantablecardioverterdefibrillatoricddevice |