Assessment of the efficiency of the use of seismic isolation by an engineer in seismic protection of buildings and structures
In many scientific research works, academician L. V. In the form proposed by Kantorovich, based on the mathematical theory of seismic risk, approaches to the application of seismic isolation for public buildings and the evaluation of its effectiveness are proposed. Costs for anti-seismic strengtheni...
Saved in:
| Main Authors: | , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
EDP Sciences
2025-01-01
|
| Series: | E3S Web of Conferences |
| Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2025/14/e3sconf_icaw2024_02007.pdf |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850195053350223872 |
|---|---|
| author | Makhmudov Said Askarova Mukhlisa Xasanov Davlatbek Valijonova Shaxnoza Yeshbayeva Farida Askarov Xasanjon |
| author_facet | Makhmudov Said Askarova Mukhlisa Xasanov Davlatbek Valijonova Shaxnoza Yeshbayeva Farida Askarov Xasanjon |
| author_sort | Makhmudov Said |
| collection | DOAJ |
| description | In many scientific research works, academician L. V. In the form proposed by Kantorovich, based on the mathematical theory of seismic risk, approaches to the application of seismic isolation for public buildings and the evaluation of its effectiveness are proposed. Costs for anti-seismic strengthening and repair work after various strong earthquakes during the life of the building were taken as efficiency criteria. The payment matrix for damage assessment was adopted for non-dense (neskalnyx) plots in relation to model series buildings. Seismic strengthening assessments were conducted for the same buildings. The evaluation of efficiency was carried out both taking into account only economic losses and also taking into account social losses. Within the framework of the regulatory legal framework, all possible options for the manifestation of seismic risk at the construction site were analyzed. |
| format | Article |
| id | doaj-art-b93a71ef10354fa4a61d92ee99365fa1 |
| institution | OA Journals |
| issn | 2267-1242 |
| language | English |
| publishDate | 2025-01-01 |
| publisher | EDP Sciences |
| record_format | Article |
| series | E3S Web of Conferences |
| spelling | doaj-art-b93a71ef10354fa4a61d92ee99365fa12025-08-20T02:13:51ZengEDP SciencesE3S Web of Conferences2267-12422025-01-016140200710.1051/e3sconf/202561402007e3sconf_icaw2024_02007Assessment of the efficiency of the use of seismic isolation by an engineer in seismic protection of buildings and structuresMakhmudov Said0Askarova Mukhlisa1Xasanov Davlatbek2Valijonova Shaxnoza3Yeshbayeva Farida4Askarov Xasanjon5Tashkent University of Architecture and ConstructionAndijan Institute of Economics and ConstructionAndijan Institute of Economics and ConstructionAndijan Institute of Economics and ConstructionTashkent University of Architecture and ConstructionAndijan Institute of Economics and ConstructionIn many scientific research works, academician L. V. In the form proposed by Kantorovich, based on the mathematical theory of seismic risk, approaches to the application of seismic isolation for public buildings and the evaluation of its effectiveness are proposed. Costs for anti-seismic strengthening and repair work after various strong earthquakes during the life of the building were taken as efficiency criteria. The payment matrix for damage assessment was adopted for non-dense (neskalnyx) plots in relation to model series buildings. Seismic strengthening assessments were conducted for the same buildings. The evaluation of efficiency was carried out both taking into account only economic losses and also taking into account social losses. Within the framework of the regulatory legal framework, all possible options for the manifestation of seismic risk at the construction site were analyzed.https://www.e3s-conferences.org/articles/e3sconf/pdf/2025/14/e3sconf_icaw2024_02007.pdf |
| spellingShingle | Makhmudov Said Askarova Mukhlisa Xasanov Davlatbek Valijonova Shaxnoza Yeshbayeva Farida Askarov Xasanjon Assessment of the efficiency of the use of seismic isolation by an engineer in seismic protection of buildings and structures E3S Web of Conferences |
| title | Assessment of the efficiency of the use of seismic isolation by an engineer in seismic protection of buildings and structures |
| title_full | Assessment of the efficiency of the use of seismic isolation by an engineer in seismic protection of buildings and structures |
| title_fullStr | Assessment of the efficiency of the use of seismic isolation by an engineer in seismic protection of buildings and structures |
| title_full_unstemmed | Assessment of the efficiency of the use of seismic isolation by an engineer in seismic protection of buildings and structures |
| title_short | Assessment of the efficiency of the use of seismic isolation by an engineer in seismic protection of buildings and structures |
| title_sort | assessment of the efficiency of the use of seismic isolation by an engineer in seismic protection of buildings and structures |
| url | https://www.e3s-conferences.org/articles/e3sconf/pdf/2025/14/e3sconf_icaw2024_02007.pdf |
| work_keys_str_mv | AT makhmudovsaid assessmentoftheefficiencyoftheuseofseismicisolationbyanengineerinseismicprotectionofbuildingsandstructures AT askarovamukhlisa assessmentoftheefficiencyoftheuseofseismicisolationbyanengineerinseismicprotectionofbuildingsandstructures AT xasanovdavlatbek assessmentoftheefficiencyoftheuseofseismicisolationbyanengineerinseismicprotectionofbuildingsandstructures AT valijonovashaxnoza assessmentoftheefficiencyoftheuseofseismicisolationbyanengineerinseismicprotectionofbuildingsandstructures AT yeshbayevafarida assessmentoftheefficiencyoftheuseofseismicisolationbyanengineerinseismicprotectionofbuildingsandstructures AT askarovxasanjon assessmentoftheefficiencyoftheuseofseismicisolationbyanengineerinseismicprotectionofbuildingsandstructures |