PROBLEMS OF EVALUATING BLOOD PRESSURE MEASUREMENT IN MODERN CLINICAL TRIALS (THE CASE OF SPRINT STUDY RESULTS)

The article presents a critical analysis of the results of a large clinical trial SPRINT. The focus is on the issues related to the blood pressure (BP) measurement in this trial.The aim of SPRINT trial was to prove the benefit of reducing systolic BP (SBP) below 120 mm Hg in high-risk hypertensive p...

Full description

Saved in:
Bibliographic Details
Main Author: V. M. Gorbunov
Format: Article
Language:English
Published: Столичная издательская компания 2018-03-01
Series:Рациональная фармакотерапия в кардиологии
Subjects:
Online Access:https://www.rpcardio.online/jour/article/view/1607
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849227680635944960
author V. M. Gorbunov
author_facet V. M. Gorbunov
author_sort V. M. Gorbunov
collection DOAJ
description The article presents a critical analysis of the results of a large clinical trial SPRINT. The focus is on the issues related to the blood pressure (BP) measurement in this trial.The aim of SPRINT trial was to prove the benefit of reducing systolic BP (SBP) below 120 mm Hg in high-risk hypertensive patients. A total, 9,631 highrisk participants without history of diabetes mellitus or stroke were randomly allocated to a standard treatment group (target SBP<140 mm Hg) or an intensive treatment group (target SBP<120 mm Hg). Significantly lower rates of all-cause mortality (by 27%) and cardiovascular events (by 25%) were observed in the intensive treatment group, compared to the standard treatment one. Therefore, the intervention was stopped early, after a mean follow-up of 3.3 years (instead of 5 years, as specified in the study protocol).However, the SPRINT study used an unusual method of clinical BP measurement, the so-called automatic office BP (AOBP) measurement. An important feature of AOBP is that it provides significantly lower BP values, compared to the conventional clinic BP measurement. This article reviews the publications which aimed to provide an independent evaluation of the SPRINT results. It appears that if traditional clinic BP measurement was used in SPRINT, the mean SBP level in the control group could be approximately 150 mm Hg, which is substantially higher than the generally accepted threshold of 140 mm Hg. This could explain a higher prevalence of cardiovascular events in the control group. The estimated SBP level in the intensive treatment group (132-136 mm Hg) is not very different from the standard threshold.Therefore, the SBP target in the treatment of hypertension remains unchanged at <140 mm Hg. AOBP is a specific subtype of the clinic BP measurement. The currently proposed AOBP threshold (135/85 mm Hg) warrants further investigation.
format Article
id doaj-art-b86576cfc41045bfb01a269bd3e7de5d
institution Kabale University
issn 1819-6446
2225-3653
language English
publishDate 2018-03-01
publisher Столичная издательская компания
record_format Article
series Рациональная фармакотерапия в кардиологии
spelling doaj-art-b86576cfc41045bfb01a269bd3e7de5d2025-08-23T10:00:29ZengСтоличная издательская компанияРациональная фармакотерапия в кардиологии1819-64462225-36532018-03-0114112213010.20996/1819-6446-2018-14-1-122-1301435PROBLEMS OF EVALUATING BLOOD PRESSURE MEASUREMENT IN MODERN CLINICAL TRIALS (THE CASE OF SPRINT STUDY RESULTS)V. M. Gorbunov0National Medical Research Center for Preventive MedicineThe article presents a critical analysis of the results of a large clinical trial SPRINT. The focus is on the issues related to the blood pressure (BP) measurement in this trial.The aim of SPRINT trial was to prove the benefit of reducing systolic BP (SBP) below 120 mm Hg in high-risk hypertensive patients. A total, 9,631 highrisk participants without history of diabetes mellitus or stroke were randomly allocated to a standard treatment group (target SBP<140 mm Hg) or an intensive treatment group (target SBP<120 mm Hg). Significantly lower rates of all-cause mortality (by 27%) and cardiovascular events (by 25%) were observed in the intensive treatment group, compared to the standard treatment one. Therefore, the intervention was stopped early, after a mean follow-up of 3.3 years (instead of 5 years, as specified in the study protocol).However, the SPRINT study used an unusual method of clinical BP measurement, the so-called automatic office BP (AOBP) measurement. An important feature of AOBP is that it provides significantly lower BP values, compared to the conventional clinic BP measurement. This article reviews the publications which aimed to provide an independent evaluation of the SPRINT results. It appears that if traditional clinic BP measurement was used in SPRINT, the mean SBP level in the control group could be approximately 150 mm Hg, which is substantially higher than the generally accepted threshold of 140 mm Hg. This could explain a higher prevalence of cardiovascular events in the control group. The estimated SBP level in the intensive treatment group (132-136 mm Hg) is not very different from the standard threshold.Therefore, the SBP target in the treatment of hypertension remains unchanged at <140 mm Hg. AOBP is a specific subtype of the clinic BP measurement. The currently proposed AOBP threshold (135/85 mm Hg) warrants further investigation.https://www.rpcardio.online/jour/article/view/1607hypertensionsprint trialclinic blood pressureautomated office blood pressuretarget blood pressure levels
spellingShingle V. M. Gorbunov
PROBLEMS OF EVALUATING BLOOD PRESSURE MEASUREMENT IN MODERN CLINICAL TRIALS (THE CASE OF SPRINT STUDY RESULTS)
Рациональная фармакотерапия в кардиологии
hypertension
sprint trial
clinic blood pressure
automated office blood pressure
target blood pressure levels
title PROBLEMS OF EVALUATING BLOOD PRESSURE MEASUREMENT IN MODERN CLINICAL TRIALS (THE CASE OF SPRINT STUDY RESULTS)
title_full PROBLEMS OF EVALUATING BLOOD PRESSURE MEASUREMENT IN MODERN CLINICAL TRIALS (THE CASE OF SPRINT STUDY RESULTS)
title_fullStr PROBLEMS OF EVALUATING BLOOD PRESSURE MEASUREMENT IN MODERN CLINICAL TRIALS (THE CASE OF SPRINT STUDY RESULTS)
title_full_unstemmed PROBLEMS OF EVALUATING BLOOD PRESSURE MEASUREMENT IN MODERN CLINICAL TRIALS (THE CASE OF SPRINT STUDY RESULTS)
title_short PROBLEMS OF EVALUATING BLOOD PRESSURE MEASUREMENT IN MODERN CLINICAL TRIALS (THE CASE OF SPRINT STUDY RESULTS)
title_sort problems of evaluating blood pressure measurement in modern clinical trials the case of sprint study results
topic hypertension
sprint trial
clinic blood pressure
automated office blood pressure
target blood pressure levels
url https://www.rpcardio.online/jour/article/view/1607
work_keys_str_mv AT vmgorbunov problemsofevaluatingbloodpressuremeasurementinmodernclinicaltrialsthecaseofsprintstudyresults