Electrochemical interaction between biodegradable ZX10 and WZ31 magnesium alloys and medical Ti6Al4V titanium alloy

Magnesium-based alloys are a modern material for the production of biodegradable (self-dissolving) surgical implants. Magnesium is a metal with the most negative electrode potential of all structural materials: −2.37 V. This means that close arrangement of implants made of magnesium, and for example...

Full description

Saved in:
Bibliographic Details
Main Authors: Pavel N. Myagkikh, Evgeny D. Merson, Vitaly A. Poluyanov, Dmitry L. Merson, Marina E. Begun
Format: Article
Language:English
Published: Togliatti State University 2024-12-01
Series:Frontier Materials & Technologies
Subjects:
Online Access:https://vektornaukitech.ru/jour/article/view/993/920
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850090347676303360
author Pavel N. Myagkikh
Evgeny D. Merson
Vitaly A. Poluyanov
Dmitry L. Merson
Marina E. Begun
author_facet Pavel N. Myagkikh
Evgeny D. Merson
Vitaly A. Poluyanov
Dmitry L. Merson
Marina E. Begun
author_sort Pavel N. Myagkikh
collection DOAJ
description Magnesium-based alloys are a modern material for the production of biodegradable (self-dissolving) surgical implants. Magnesium is a metal with the most negative electrode potential of all structural materials: −2.37 V. This means that close arrangement of implants made of magnesium, and for example, titanium alloys will lead to the occurrence of a galvanic effect, and accelerated electrochemical corrosion of magnesium. However, it is unknown how the ratio of the areas of titanium and magnesium products affects the magnitude of this effect. This work covers this issue. In the presented study, cylindrical samples of biodegradable ZX10 and WZ31 magnesium alloys were placed in physiological Ringer’s solution at a distance of 3 cm, from a sample of medical Ti6Al4V alloy of the same shape and size. During the test, the temperature of the corrosive environment was maintained at 37 °C. The series of experiments included corrosion tests lasting three days with the participation of one, two or four magnesium samples, thus the area ratios between the titanium and magnesium alloy were 1:1, 1:2 and 1:4. It was found that for both magnesium alloys, with an increase in the area ratio, the effect of electrochemical action decreases significantly, which is expressed in a decrease in the corrosion rate. At the same time, for the WZ31 alloy, the effect of the presence of Ti6Al4V on the corrosion rate is significantly weaker than for ZX10, which is explained by the presence of the LPSO phase in the alloy, as well as a more alloyed matrix and, accordingly, having a more positive electrode potential.
format Article
id doaj-art-b80536a2f1d5451bb561124a0960aad7
institution DOAJ
issn 2782-4039
2782-6074
language English
publishDate 2024-12-01
publisher Togliatti State University
record_format Article
series Frontier Materials & Technologies
spelling doaj-art-b80536a2f1d5451bb561124a0960aad72025-08-20T02:42:35ZengTogliatti State UniversityFrontier Materials & Technologies2782-40392782-60742024-12-01-4637110.18323/2782-4039-2024-4-70-6Electrochemical interaction between biodegradable ZX10 and WZ31 magnesium alloys and medical Ti6Al4V titanium alloyPavel N. Myagkikh0https://orcid.org/0000-0002-7530-9518Evgeny D. Merson1https://orcid.org/0000-0002-7063-088XVitaly A. Poluyanov2https://orcid.org/0000-0002-0570-2584Dmitry L. Merson3https://orcid.org/0000-0001-5006-4115Marina E. Begun4Togliatti State University, Togliatti (Russia)Togliatti State University, Togliatti (Russia)Togliatti State University, Togliatti (Russia)Togliatti State University, Togliatti (Russia)Togliatti State University, Togliatti (Russia)Magnesium-based alloys are a modern material for the production of biodegradable (self-dissolving) surgical implants. Magnesium is a metal with the most negative electrode potential of all structural materials: −2.37 V. This means that close arrangement of implants made of magnesium, and for example, titanium alloys will lead to the occurrence of a galvanic effect, and accelerated electrochemical corrosion of magnesium. However, it is unknown how the ratio of the areas of titanium and magnesium products affects the magnitude of this effect. This work covers this issue. In the presented study, cylindrical samples of biodegradable ZX10 and WZ31 magnesium alloys were placed in physiological Ringer’s solution at a distance of 3 cm, from a sample of medical Ti6Al4V alloy of the same shape and size. During the test, the temperature of the corrosive environment was maintained at 37 °C. The series of experiments included corrosion tests lasting three days with the participation of one, two or four magnesium samples, thus the area ratios between the titanium and magnesium alloy were 1:1, 1:2 and 1:4. It was found that for both magnesium alloys, with an increase in the area ratio, the effect of electrochemical action decreases significantly, which is expressed in a decrease in the corrosion rate. At the same time, for the WZ31 alloy, the effect of the presence of Ti6Al4V on the corrosion rate is significantly weaker than for ZX10, which is explained by the presence of the LPSO phase in the alloy, as well as a more alloyed matrix and, accordingly, having a more positive electrode potential.https://vektornaukitech.ru/jour/article/view/993/920surgical implantselectrochemical corrosionbiodegradable materialsmagnesium alloyszx10wz31titanium alloysti6al4vmedical materialscorrosion rateelectrode potential
spellingShingle Pavel N. Myagkikh
Evgeny D. Merson
Vitaly A. Poluyanov
Dmitry L. Merson
Marina E. Begun
Electrochemical interaction between biodegradable ZX10 and WZ31 magnesium alloys and medical Ti6Al4V titanium alloy
Frontier Materials & Technologies
surgical implants
electrochemical corrosion
biodegradable materials
magnesium alloys
zx10
wz31
titanium alloys
ti6al4v
medical materials
corrosion rate
electrode potential
title Electrochemical interaction between biodegradable ZX10 and WZ31 magnesium alloys and medical Ti6Al4V titanium alloy
title_full Electrochemical interaction between biodegradable ZX10 and WZ31 magnesium alloys and medical Ti6Al4V titanium alloy
title_fullStr Electrochemical interaction between biodegradable ZX10 and WZ31 magnesium alloys and medical Ti6Al4V titanium alloy
title_full_unstemmed Electrochemical interaction between biodegradable ZX10 and WZ31 magnesium alloys and medical Ti6Al4V titanium alloy
title_short Electrochemical interaction between biodegradable ZX10 and WZ31 magnesium alloys and medical Ti6Al4V titanium alloy
title_sort electrochemical interaction between biodegradable zx10 and wz31 magnesium alloys and medical ti6al4v titanium alloy
topic surgical implants
electrochemical corrosion
biodegradable materials
magnesium alloys
zx10
wz31
titanium alloys
ti6al4v
medical materials
corrosion rate
electrode potential
url https://vektornaukitech.ru/jour/article/view/993/920
work_keys_str_mv AT pavelnmyagkikh electrochemicalinteractionbetweenbiodegradablezx10andwz31magnesiumalloysandmedicalti6al4vtitaniumalloy
AT evgenydmerson electrochemicalinteractionbetweenbiodegradablezx10andwz31magnesiumalloysandmedicalti6al4vtitaniumalloy
AT vitalyapoluyanov electrochemicalinteractionbetweenbiodegradablezx10andwz31magnesiumalloysandmedicalti6al4vtitaniumalloy
AT dmitrylmerson electrochemicalinteractionbetweenbiodegradablezx10andwz31magnesiumalloysandmedicalti6al4vtitaniumalloy
AT marinaebegun electrochemicalinteractionbetweenbiodegradablezx10andwz31magnesiumalloysandmedicalti6al4vtitaniumalloy