A novel nanomaterial baffle decrease aerosols and microbial aerosols during non-contact tonometry measurements

<p> X. Shen, Y. Guo, X. Wang, Y. Ye, Q. Chi, W. Zhou, Y. Xu, P. Wu, H. Zhou, Y. Chen, C. Li, Y. Chen </p> <p> Wenzhou Medical University, Wenzhou, China </p> <p> <b>Aim:</b> to develop a novel baffle to decrease aerosols and microbial aerosols produced...

Full description

Saved in:
Bibliographic Details
Main Authors: X. Shen, Y. Guo, X, X. Wang, Y. Ye, Q. Chi, W. Zhou, Y. Chen, C. Li
Format: Article
Language:Russian
Published: Prime-Media 2024-12-01
Series:РМЖ "Клиническая офтальмология"
Online Access:http://clinopht.com/upload/iblock/844/053r4z208sgvu44a9uk7moea6hbjgwj6.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841526906730577920
author X. Shen
Y. Guo, X
X. Wang
Y. Ye
Q. Chi
W. Zhou
Y. Chen
C. Li
author_facet X. Shen
Y. Guo, X
X. Wang
Y. Ye
Q. Chi
W. Zhou
Y. Chen
C. Li
author_sort X. Shen
collection DOAJ
description <p> X. Shen, Y. Guo, X. Wang, Y. Ye, Q. Chi, W. Zhou, Y. Xu, P. Wu, H. Zhou, Y. Chen, C. Li, Y. Chen </p> <p> Wenzhou Medical University, Wenzhou, China </p> <p> <b>Aim:</b> to develop a novel baffle to decrease aerosols and microbial aerosols produced during non-contact tonometry (NCT) measurements. </p> <p> <b>Materials and Methods: </b>the cluster analysis performed by Autof Analyzer software contained in MALDI-TOF MS (Autof MS 600, Autobio, China) based on microbes detected in microbial aerosols samples during NCT measurements, in human conjunctiva samples, in the air and typical strains in the database. Overall, 1594 person-time were included. The participants randomly divided into groups: NCT with a novel antimicrobial aerosol nanocomposite baffle (Group 1), NCT with a plastic baffle (Group 2), NCT without a baffle (Group 3) and participants without NCT measurements (Background investigation). NCT measurements performed in Groups 1–3.We used Air quality detectors and Air Ideal® 3P to monitor and sample aerosols and microbial aerosols during NCT measurements. Blood agar plates (Bio-kont, China) were used in the microbial sampler with a diameter of 90 mm. The plates were kept in aerobic conditions at about 25°C for 3–5 days, then the colonies on the plates were counted. </p> <p> <b>Results: </b>Staphylococcus epidermidis from microbial aerosols samples cluster with those from human samples rather than those from air. Burkholderia spp. and other microbes tested in the microbial aerosols cluster with each other rather than those in the air. Aerosols and microbial aerosols in the background did not show stable accumulation effect nor upward trend. Compared with the increasing trend of aerosols and microbial aerosols in Group 2 and Group 3, those in Group 1 were low,and showing a significant downward trend. </p> <p> <b>Conclusion: </b>Aerosolized ocular surface microorganisms (AOSM) can spread by human eyes NCT measured, pathogens may among them. The effect of plastic baffle was beneficial but volatile. Antimicrobial aerosol nano-composite baffle can effectively reduce aerosols and microbial aerosols during NCT measurements. </p> <p> <b>Keywords: </b>Baffle, Bio-aerosols, Global human health, Nanocomposites, Non-contact tonometer, COVID-19, Infection surveillance and control, Glaucoma, Cornea, Sampling method. </p> <p> <b>For citation:</b> Shen X., Guo Y., Wang X., Ye Y., Chi Q., Zhou W., Xu Y., Wu P., Zhou H., Chen Y., Li C., Chen Y. A novel nanomaterial baffle decrease aerosols and microbial aerosols during non-contact tonometry measurements. Russian Journal of Clinical Ophthalmology. 2024;24(4):217–221 (in Russ.). DOI: 10.32364/2311-7729-2024-24-4-9 </p>
format Article
id doaj-art-b77b25ed8f4642be9bec7e54448fe766
institution Kabale University
issn 2311-7729
2619-1571
language Russian
publishDate 2024-12-01
publisher Prime-Media
record_format Article
series РМЖ "Клиническая офтальмология"
spelling doaj-art-b77b25ed8f4642be9bec7e54448fe7662025-01-16T09:39:38ZrusPrime-MediaРМЖ "Клиническая офтальмология"2311-77292619-15712024-12-0124431817A novel nanomaterial baffle decrease aerosols and microbial aerosols during non-contact tonometry measurementsX. Shen0Y. Guo, X1X. Wang2Y. Ye3Q. Chi4W. Zhou5678Y. Chen9C. Li10Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399<p> X. Shen, Y. Guo, X. Wang, Y. Ye, Q. Chi, W. Zhou, Y. Xu, P. Wu, H. Zhou, Y. Chen, C. Li, Y. Chen </p> <p> Wenzhou Medical University, Wenzhou, China </p> <p> <b>Aim:</b> to develop a novel baffle to decrease aerosols and microbial aerosols produced during non-contact tonometry (NCT) measurements. </p> <p> <b>Materials and Methods: </b>the cluster analysis performed by Autof Analyzer software contained in MALDI-TOF MS (Autof MS 600, Autobio, China) based on microbes detected in microbial aerosols samples during NCT measurements, in human conjunctiva samples, in the air and typical strains in the database. Overall, 1594 person-time were included. The participants randomly divided into groups: NCT with a novel antimicrobial aerosol nanocomposite baffle (Group 1), NCT with a plastic baffle (Group 2), NCT without a baffle (Group 3) and participants without NCT measurements (Background investigation). NCT measurements performed in Groups 1–3.We used Air quality detectors and Air Ideal® 3P to monitor and sample aerosols and microbial aerosols during NCT measurements. Blood agar plates (Bio-kont, China) were used in the microbial sampler with a diameter of 90 mm. The plates were kept in aerobic conditions at about 25°C for 3–5 days, then the colonies on the plates were counted. </p> <p> <b>Results: </b>Staphylococcus epidermidis from microbial aerosols samples cluster with those from human samples rather than those from air. Burkholderia spp. and other microbes tested in the microbial aerosols cluster with each other rather than those in the air. Aerosols and microbial aerosols in the background did not show stable accumulation effect nor upward trend. Compared with the increasing trend of aerosols and microbial aerosols in Group 2 and Group 3, those in Group 1 were low,and showing a significant downward trend. </p> <p> <b>Conclusion: </b>Aerosolized ocular surface microorganisms (AOSM) can spread by human eyes NCT measured, pathogens may among them. The effect of plastic baffle was beneficial but volatile. Antimicrobial aerosol nano-composite baffle can effectively reduce aerosols and microbial aerosols during NCT measurements. </p> <p> <b>Keywords: </b>Baffle, Bio-aerosols, Global human health, Nanocomposites, Non-contact tonometer, COVID-19, Infection surveillance and control, Glaucoma, Cornea, Sampling method. </p> <p> <b>For citation:</b> Shen X., Guo Y., Wang X., Ye Y., Chi Q., Zhou W., Xu Y., Wu P., Zhou H., Chen Y., Li C., Chen Y. A novel nanomaterial baffle decrease aerosols and microbial aerosols during non-contact tonometry measurements. Russian Journal of Clinical Ophthalmology. 2024;24(4):217–221 (in Russ.). DOI: 10.32364/2311-7729-2024-24-4-9 </p>http://clinopht.com/upload/iblock/844/053r4z208sgvu44a9uk7moea6hbjgwj6.pdf
spellingShingle X. Shen
Y. Guo, X
X. Wang
Y. Ye
Q. Chi
W. Zhou
Y. Chen
C. Li
A novel nanomaterial baffle decrease aerosols and microbial aerosols during non-contact tonometry measurements
РМЖ "Клиническая офтальмология"
title A novel nanomaterial baffle decrease aerosols and microbial aerosols during non-contact tonometry measurements
title_full A novel nanomaterial baffle decrease aerosols and microbial aerosols during non-contact tonometry measurements
title_fullStr A novel nanomaterial baffle decrease aerosols and microbial aerosols during non-contact tonometry measurements
title_full_unstemmed A novel nanomaterial baffle decrease aerosols and microbial aerosols during non-contact tonometry measurements
title_short A novel nanomaterial baffle decrease aerosols and microbial aerosols during non-contact tonometry measurements
title_sort novel nanomaterial baffle decrease aerosols and microbial aerosols during non contact tonometry measurements
url http://clinopht.com/upload/iblock/844/053r4z208sgvu44a9uk7moea6hbjgwj6.pdf
work_keys_str_mv AT xshen anovelnanomaterialbaffledecreaseaerosolsandmicrobialaerosolsduringnoncontacttonometrymeasurements
AT yguox anovelnanomaterialbaffledecreaseaerosolsandmicrobialaerosolsduringnoncontacttonometrymeasurements
AT xwang anovelnanomaterialbaffledecreaseaerosolsandmicrobialaerosolsduringnoncontacttonometrymeasurements
AT yye anovelnanomaterialbaffledecreaseaerosolsandmicrobialaerosolsduringnoncontacttonometrymeasurements
AT qchi anovelnanomaterialbaffledecreaseaerosolsandmicrobialaerosolsduringnoncontacttonometrymeasurements
AT wzhou anovelnanomaterialbaffledecreaseaerosolsandmicrobialaerosolsduringnoncontacttonometrymeasurements
AT ychen anovelnanomaterialbaffledecreaseaerosolsandmicrobialaerosolsduringnoncontacttonometrymeasurements
AT cli anovelnanomaterialbaffledecreaseaerosolsandmicrobialaerosolsduringnoncontacttonometrymeasurements
AT xshen novelnanomaterialbaffledecreaseaerosolsandmicrobialaerosolsduringnoncontacttonometrymeasurements
AT yguox novelnanomaterialbaffledecreaseaerosolsandmicrobialaerosolsduringnoncontacttonometrymeasurements
AT xwang novelnanomaterialbaffledecreaseaerosolsandmicrobialaerosolsduringnoncontacttonometrymeasurements
AT yye novelnanomaterialbaffledecreaseaerosolsandmicrobialaerosolsduringnoncontacttonometrymeasurements
AT qchi novelnanomaterialbaffledecreaseaerosolsandmicrobialaerosolsduringnoncontacttonometrymeasurements
AT wzhou novelnanomaterialbaffledecreaseaerosolsandmicrobialaerosolsduringnoncontacttonometrymeasurements
AT ychen novelnanomaterialbaffledecreaseaerosolsandmicrobialaerosolsduringnoncontacttonometrymeasurements
AT cli novelnanomaterialbaffledecreaseaerosolsandmicrobialaerosolsduringnoncontacttonometrymeasurements