Successful Management of Unexpected Massive Blood Loss during Robot-assisted Partial Nephrectomy: A Case Report

Robot-assisted Partial Nephrectomy (RAPN) for Renal Cell Carcinoma (RCC) is a minimally invasive surgery with reconstructive potential. Due to the high vascularity associated with RCC and the steep learning curve of robotic surgery, the risk of vascular injury is elevated. Authors hereby, report a c...

Full description

Saved in:
Bibliographic Details
Main Authors: Sandip Baheti, Prashant Sakhavalkar, Runjhun Jain, Utkarshini Kedia, M Sharan
Format: Article
Language:English
Published: JCDR Research and Publications Private Limited 2025-07-01
Series:Journal of Clinical and Diagnostic Research
Subjects:
Online Access:https://jcdr.net/article_fulltext.asp?issn=0973-709x&year=2025&month=July&volume=19&issue=7&page=UD11-UD13&id=21230
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850073708914278400
author Sandip Baheti
Prashant Sakhavalkar
Runjhun Jain
Utkarshini Kedia
M Sharan
author_facet Sandip Baheti
Prashant Sakhavalkar
Runjhun Jain
Utkarshini Kedia
M Sharan
author_sort Sandip Baheti
collection DOAJ
description Robot-assisted Partial Nephrectomy (RAPN) for Renal Cell Carcinoma (RCC) is a minimally invasive surgery with reconstructive potential. Due to the high vascularity associated with RCC and the steep learning curve of robotic surgery, the risk of vascular injury is elevated. Authors hereby, report a case of a 50-year-old female scheduled for RAPN, which was later converted to open nephrectomy. During the surgery, there was an accidental massive haemorrhage and hypotension due to a sudden iatrogenic rupture of the Inferior Vena Cava (IVC). Although two units of Packed Cell Volume (PCV) and Fresh Frozen Plasma (FFP) had been reserved, massive haemorrhage and hypotension occurred suddenly, and as the blood bank was not in the same building, blood was not readily available. Additionally, managing the massive haemorrhage and hypotension was challenging due to spatial restrictions and the difficulty in accurately judging blood loss during robotic surgery. To maintain cerebral circulation, a head-down position with a left tilt was useful, as this positioned the heart at its most dependent position for maximum venous drainage. To save time and avoid delays in resuscitation authors implemented their implemented our Contact-Act-Coordinate-Correlate (CACC) protocol alongside clinical guidelines. The importance of prompt action and aggressive fluid transfusion until blood became available cannot be overstated; it is crucial not to wait for ideal fluids if they are not readily available, as maintaining microcirculation is a priority. Moreover, frequent laboratory investigations and correlation should not be neglected. However minimally invasive the surgery may be, prior blood grouping and cross-matching are essential for managing unexpected bleeding complications during such procedures.
format Article
id doaj-art-b7753acf831d4edeaaf69fcbc718504f
institution DOAJ
issn 2249-782X
0973-709X
language English
publishDate 2025-07-01
publisher JCDR Research and Publications Private Limited
record_format Article
series Journal of Clinical and Diagnostic Research
spelling doaj-art-b7753acf831d4edeaaf69fcbc718504f2025-08-20T02:46:44ZengJCDR Research and Publications Private LimitedJournal of Clinical and Diagnostic Research2249-782X0973-709X2025-07-01197UD11UD1310.7860/JCDR/2025/76891.21230Successful Management of Unexpected Massive Blood Loss during Robot-assisted Partial Nephrectomy: A Case ReportSandip Baheti0Prashant Sakhavalkar1Runjhun Jain2Utkarshini Kedia3M Sharan4Professor, Department of Anaesthesiology, Dr. D. Y. Patil Medical College, Hospital and Research Centre, Pimpri, Pune, Maharashtra, India.Associate Professor, Department of Critical Care Medicine, Dr. D. Y. Patil Medical College, Hospital and Research Centre, Pimpri, Pune, Maharashtra, India.Resident, Department of Anaesthesiology, Dr. D. Y. Patil Medical College, Hospital and Research Centre, Pimpri, Pune, Maharashtra, India.Assistant Professor, Department of Anaesthesiology, Dr. D. Y. Patil Medical College, Hospital and Research Centre, Pimpri, Pune, Maharashtra, India.Resident, Department of Anaesthesiology, Dr. D. Y. Patil Medical College, Hospital and Research Centre, Pimpri, Pune, Maharashtra, India.Robot-assisted Partial Nephrectomy (RAPN) for Renal Cell Carcinoma (RCC) is a minimally invasive surgery with reconstructive potential. Due to the high vascularity associated with RCC and the steep learning curve of robotic surgery, the risk of vascular injury is elevated. Authors hereby, report a case of a 50-year-old female scheduled for RAPN, which was later converted to open nephrectomy. During the surgery, there was an accidental massive haemorrhage and hypotension due to a sudden iatrogenic rupture of the Inferior Vena Cava (IVC). Although two units of Packed Cell Volume (PCV) and Fresh Frozen Plasma (FFP) had been reserved, massive haemorrhage and hypotension occurred suddenly, and as the blood bank was not in the same building, blood was not readily available. Additionally, managing the massive haemorrhage and hypotension was challenging due to spatial restrictions and the difficulty in accurately judging blood loss during robotic surgery. To maintain cerebral circulation, a head-down position with a left tilt was useful, as this positioned the heart at its most dependent position for maximum venous drainage. To save time and avoid delays in resuscitation authors implemented their implemented our Contact-Act-Coordinate-Correlate (CACC) protocol alongside clinical guidelines. The importance of prompt action and aggressive fluid transfusion until blood became available cannot be overstated; it is crucial not to wait for ideal fluids if they are not readily available, as maintaining microcirculation is a priority. Moreover, frequent laboratory investigations and correlation should not be neglected. However minimally invasive the surgery may be, prior blood grouping and cross-matching are essential for managing unexpected bleeding complications during such procedures.https://jcdr.net/article_fulltext.asp?issn=0973-709x&year=2025&month=July&volume=19&issue=7&page=UD11-UD13&id=21230cannulascirculationvasopressor
spellingShingle Sandip Baheti
Prashant Sakhavalkar
Runjhun Jain
Utkarshini Kedia
M Sharan
Successful Management of Unexpected Massive Blood Loss during Robot-assisted Partial Nephrectomy: A Case Report
Journal of Clinical and Diagnostic Research
cannulas
circulation
vasopressor
title Successful Management of Unexpected Massive Blood Loss during Robot-assisted Partial Nephrectomy: A Case Report
title_full Successful Management of Unexpected Massive Blood Loss during Robot-assisted Partial Nephrectomy: A Case Report
title_fullStr Successful Management of Unexpected Massive Blood Loss during Robot-assisted Partial Nephrectomy: A Case Report
title_full_unstemmed Successful Management of Unexpected Massive Blood Loss during Robot-assisted Partial Nephrectomy: A Case Report
title_short Successful Management of Unexpected Massive Blood Loss during Robot-assisted Partial Nephrectomy: A Case Report
title_sort successful management of unexpected massive blood loss during robot assisted partial nephrectomy a case report
topic cannulas
circulation
vasopressor
url https://jcdr.net/article_fulltext.asp?issn=0973-709x&year=2025&month=July&volume=19&issue=7&page=UD11-UD13&id=21230
work_keys_str_mv AT sandipbaheti successfulmanagementofunexpectedmassivebloodlossduringrobotassistedpartialnephrectomyacasereport
AT prashantsakhavalkar successfulmanagementofunexpectedmassivebloodlossduringrobotassistedpartialnephrectomyacasereport
AT runjhunjain successfulmanagementofunexpectedmassivebloodlossduringrobotassistedpartialnephrectomyacasereport
AT utkarshinikedia successfulmanagementofunexpectedmassivebloodlossduringrobotassistedpartialnephrectomyacasereport
AT msharan successfulmanagementofunexpectedmassivebloodlossduringrobotassistedpartialnephrectomyacasereport