Remote Stab Wound Resulting in AV Fistula and High-Output Heart Failure
A 54-year-old African American male with no medical history presented to an urgent care clinic with signs and symptoms of new-onset congestive heart failure. There was an initial concern for congestive heart failure secondary to an ischemic etiology as an echocardiogram revealed a depressed ejection...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2013-01-01
|
Series: | Case Reports in Cardiology |
Online Access: | http://dx.doi.org/10.1155/2013/902719 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832551486903549952 |
---|---|
author | Jennifer A. Rymer Lindsay L. Anderson J. Trevor Posenau W. Schuyler Jones |
author_facet | Jennifer A. Rymer Lindsay L. Anderson J. Trevor Posenau W. Schuyler Jones |
author_sort | Jennifer A. Rymer |
collection | DOAJ |
description | A 54-year-old African American male with no medical history presented to an urgent care clinic with signs and symptoms of new-onset congestive heart failure. There was an initial concern for congestive heart failure secondary to an ischemic etiology as an echocardiogram revealed a depressed ejection fraction. However, a left heart cardiac catheterization did not demonstrate any significant coronary disease. As a loud bruit was auscultated over the right base of the patient’s neck, he underwent a carotid duplex ultrasound revealing a fistula between the right common carotid artery (CCA) and the right internal jugular vein (IJV). A diagnosis of high-output heart failure secondary to a large arteriovenous (AV) fistula was made, and the patient underwent ligation and repair of the fistula with resolution of symptoms of congestive heart failure. |
format | Article |
id | doaj-art-b68278a599ea4c2d9ded60c0663bd83b |
institution | Kabale University |
issn | 2090-6404 2090-6412 |
language | English |
publishDate | 2013-01-01 |
publisher | Wiley |
record_format | Article |
series | Case Reports in Cardiology |
spelling | doaj-art-b68278a599ea4c2d9ded60c0663bd83b2025-02-03T06:01:22ZengWileyCase Reports in Cardiology2090-64042090-64122013-01-01201310.1155/2013/902719902719Remote Stab Wound Resulting in AV Fistula and High-Output Heart FailureJennifer A. Rymer0Lindsay L. Anderson1J. Trevor Posenau2W. Schuyler Jones3Duke University Medical Center, Hospital North 7402, DUMC Box 3126, Durham, NC 27710, USADuke University Medical Center, Hospital North 7402, DUMC Box 3126, Durham, NC 27710, USADuke University Medical Center, Hospital North 7402, DUMC Box 3126, Durham, NC 27710, USADuke University Medical Center, Hospital North 7402, DUMC Box 3126, Durham, NC 27710, USAA 54-year-old African American male with no medical history presented to an urgent care clinic with signs and symptoms of new-onset congestive heart failure. There was an initial concern for congestive heart failure secondary to an ischemic etiology as an echocardiogram revealed a depressed ejection fraction. However, a left heart cardiac catheterization did not demonstrate any significant coronary disease. As a loud bruit was auscultated over the right base of the patient’s neck, he underwent a carotid duplex ultrasound revealing a fistula between the right common carotid artery (CCA) and the right internal jugular vein (IJV). A diagnosis of high-output heart failure secondary to a large arteriovenous (AV) fistula was made, and the patient underwent ligation and repair of the fistula with resolution of symptoms of congestive heart failure.http://dx.doi.org/10.1155/2013/902719 |
spellingShingle | Jennifer A. Rymer Lindsay L. Anderson J. Trevor Posenau W. Schuyler Jones Remote Stab Wound Resulting in AV Fistula and High-Output Heart Failure Case Reports in Cardiology |
title | Remote Stab Wound Resulting in AV Fistula and High-Output Heart Failure |
title_full | Remote Stab Wound Resulting in AV Fistula and High-Output Heart Failure |
title_fullStr | Remote Stab Wound Resulting in AV Fistula and High-Output Heart Failure |
title_full_unstemmed | Remote Stab Wound Resulting in AV Fistula and High-Output Heart Failure |
title_short | Remote Stab Wound Resulting in AV Fistula and High-Output Heart Failure |
title_sort | remote stab wound resulting in av fistula and high output heart failure |
url | http://dx.doi.org/10.1155/2013/902719 |
work_keys_str_mv | AT jenniferarymer remotestabwoundresultinginavfistulaandhighoutputheartfailure AT lindsaylanderson remotestabwoundresultinginavfistulaandhighoutputheartfailure AT jtrevorposenau remotestabwoundresultinginavfistulaandhighoutputheartfailure AT wschuylerjones remotestabwoundresultinginavfistulaandhighoutputheartfailure |