Establishment of Passive Energy Conservation Measure and Economic Evaluation of Fenestration System in Nonresidential Building of Korea
ECO2 (building energy efficiency rating program) and passive energy conservation measures (ECMs) were established as a basic study for targeted methodologies and decision support systems development in Korea to meet national regulations. The primary energy consumption and economic evaluation of nonr...
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Wiley
2017-01-01
|
| Series: | International Journal of Polymer Science |
| Online Access: | http://dx.doi.org/10.1155/2017/8681737 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850159812498685952 |
|---|---|
| author | Bo-Eun Choi Ji-Hyun Shin Jin-Hyun Lee Sun-Sook Kim Young-Hum Cho |
| author_facet | Bo-Eun Choi Ji-Hyun Shin Jin-Hyun Lee Sun-Sook Kim Young-Hum Cho |
| author_sort | Bo-Eun Choi |
| collection | DOAJ |
| description | ECO2 (building energy efficiency rating program) and passive energy conservation measures (ECMs) were established as a basic study for targeted methodologies and decision support systems development in Korea to meet national regulations. The primary energy consumption and economic evaluation of nonresidential buildings was performed. Passive ECMs were classified as planning and performance elements. The planning elements are the window-to-wall ratio (WWR) and horizontal shading angle. The performance elements are the thermal transmittance (U-value) of the walls, roof, and floor and the U-value and solar heat gain coefficient (SHGC) of windows. This study focused on the window-to-wall ratio and the U-value and solar heat gain coefficient of windows. An economic efficiency database for the constructed alternatives was built; the target building was set and the Passive ECM List for the target building was derived. The energy consumption evaluation and economic evaluation were performed for each of the constructed alternatives, and a methodology for guiding energy efficiency decisions was proposed based on the performance evaluation results, and the optimal Passive ECM List for the target building was derived. |
| format | Article |
| id | doaj-art-b558296614b946008bdba3ca1f5ebfdc |
| institution | OA Journals |
| issn | 1687-9422 1687-9430 |
| language | English |
| publishDate | 2017-01-01 |
| publisher | Wiley |
| record_format | Article |
| series | International Journal of Polymer Science |
| spelling | doaj-art-b558296614b946008bdba3ca1f5ebfdc2025-08-20T02:23:23ZengWileyInternational Journal of Polymer Science1687-94221687-94302017-01-01201710.1155/2017/86817378681737Establishment of Passive Energy Conservation Measure and Economic Evaluation of Fenestration System in Nonresidential Building of KoreaBo-Eun Choi0Ji-Hyun Shin1Jin-Hyun Lee2Sun-Sook Kim3Young-Hum Cho4Green Architecture Center, Korea Institute of Building Energy Technology, Seoul, Republic of KoreaDepartment of Architectural Engineering, Graduate School of Yeungnam University, Gyeongsan, Republic of KoreaDepartment of Architectural Engineering, Graduate School of Yeungnam University, Gyeongsan, Republic of KoreaDepartment of Architecture, Ajou University, Gyeonggi, Republic of KoreaSchool of Architecture, Yeungnam University, Gyeongsan, Republic of KoreaECO2 (building energy efficiency rating program) and passive energy conservation measures (ECMs) were established as a basic study for targeted methodologies and decision support systems development in Korea to meet national regulations. The primary energy consumption and economic evaluation of nonresidential buildings was performed. Passive ECMs were classified as planning and performance elements. The planning elements are the window-to-wall ratio (WWR) and horizontal shading angle. The performance elements are the thermal transmittance (U-value) of the walls, roof, and floor and the U-value and solar heat gain coefficient (SHGC) of windows. This study focused on the window-to-wall ratio and the U-value and solar heat gain coefficient of windows. An economic efficiency database for the constructed alternatives was built; the target building was set and the Passive ECM List for the target building was derived. The energy consumption evaluation and economic evaluation were performed for each of the constructed alternatives, and a methodology for guiding energy efficiency decisions was proposed based on the performance evaluation results, and the optimal Passive ECM List for the target building was derived.http://dx.doi.org/10.1155/2017/8681737 |
| spellingShingle | Bo-Eun Choi Ji-Hyun Shin Jin-Hyun Lee Sun-Sook Kim Young-Hum Cho Establishment of Passive Energy Conservation Measure and Economic Evaluation of Fenestration System in Nonresidential Building of Korea International Journal of Polymer Science |
| title | Establishment of Passive Energy Conservation Measure and Economic Evaluation of Fenestration System in Nonresidential Building of Korea |
| title_full | Establishment of Passive Energy Conservation Measure and Economic Evaluation of Fenestration System in Nonresidential Building of Korea |
| title_fullStr | Establishment of Passive Energy Conservation Measure and Economic Evaluation of Fenestration System in Nonresidential Building of Korea |
| title_full_unstemmed | Establishment of Passive Energy Conservation Measure and Economic Evaluation of Fenestration System in Nonresidential Building of Korea |
| title_short | Establishment of Passive Energy Conservation Measure and Economic Evaluation of Fenestration System in Nonresidential Building of Korea |
| title_sort | establishment of passive energy conservation measure and economic evaluation of fenestration system in nonresidential building of korea |
| url | http://dx.doi.org/10.1155/2017/8681737 |
| work_keys_str_mv | AT boeunchoi establishmentofpassiveenergyconservationmeasureandeconomicevaluationoffenestrationsysteminnonresidentialbuildingofkorea AT jihyunshin establishmentofpassiveenergyconservationmeasureandeconomicevaluationoffenestrationsysteminnonresidentialbuildingofkorea AT jinhyunlee establishmentofpassiveenergyconservationmeasureandeconomicevaluationoffenestrationsysteminnonresidentialbuildingofkorea AT sunsookkim establishmentofpassiveenergyconservationmeasureandeconomicevaluationoffenestrationsysteminnonresidentialbuildingofkorea AT younghumcho establishmentofpassiveenergyconservationmeasureandeconomicevaluationoffenestrationsysteminnonresidentialbuildingofkorea |