Research on Performance of Scroll Compressor and System under Suction Injection

In order to analyze the relationship between the suction injection and the performance of the scroll compressor, the suction injection circuit was set up. And the mathematic model, containing the loss of leakage and heat exchange, was established at the same time. The discharge temperature and the r...

Full description

Saved in:
Bibliographic Details
Main Authors: Yin Xiang, Sun Shuaihui, Cao Feng, Shu Pengcheng
Format: Article
Language:zho
Published: Journal of Refrigeration Magazines Agency Co., Ltd. 2015-01-01
Series:Zhileng xuebao
Online Access:http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2015.05.010
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849707425652801536
author Yin Xiang
Sun Shuaihui
Cao Feng
Shu Pengcheng
author_facet Yin Xiang
Sun Shuaihui
Cao Feng
Shu Pengcheng
author_sort Yin Xiang
collection DOAJ
description In order to analyze the relationship between the suction injection and the performance of the scroll compressor, the suction injection circuit was set up. And the mathematic model, containing the loss of leakage and heat exchange, was established at the same time. The discharge temperature and the refrigerating capacity and the COP of the system were investigated when the injection flow rate and the pressure ratio were varied. The result of the simulation was in reasonable agreement with the experimental data. The error was 2.5% at the low injection flow, and 10% at the high flow. It was also found that the discharge temperature decreased and the COP slightly increased then went down, when the injection flow increased. The COP of the system increased by 0.6%, while the discharge temperature decreased by 14 ℃ at the condition of the low injection flow. When the discharge temperature decreased by 42 ℃, the decline in the COP was less than 5%. Additionally, there existed an optimal value of the COP in the suction injection circuit when the injection flow varied at the high pressure ratio. Furthermore, the higher the pressure ratio was, the lower the COP decreased. As a result, the suction injection could put into use to decrease the discharge temperature.
format Article
id doaj-art-b47b8ecc7d444875b67d81d2a6d54123
institution DOAJ
issn 0253-4339
language zho
publishDate 2015-01-01
publisher Journal of Refrigeration Magazines Agency Co., Ltd.
record_format Article
series Zhileng xuebao
spelling doaj-art-b47b8ecc7d444875b67d81d2a6d541232025-08-20T03:15:54ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392015-01-013666513974Research on Performance of Scroll Compressor and System under Suction InjectionYin XiangSun ShuaihuiCao FengShu PengchengIn order to analyze the relationship between the suction injection and the performance of the scroll compressor, the suction injection circuit was set up. And the mathematic model, containing the loss of leakage and heat exchange, was established at the same time. The discharge temperature and the refrigerating capacity and the COP of the system were investigated when the injection flow rate and the pressure ratio were varied. The result of the simulation was in reasonable agreement with the experimental data. The error was 2.5% at the low injection flow, and 10% at the high flow. It was also found that the discharge temperature decreased and the COP slightly increased then went down, when the injection flow increased. The COP of the system increased by 0.6%, while the discharge temperature decreased by 14 ℃ at the condition of the low injection flow. When the discharge temperature decreased by 42 ℃, the decline in the COP was less than 5%. Additionally, there existed an optimal value of the COP in the suction injection circuit when the injection flow varied at the high pressure ratio. Furthermore, the higher the pressure ratio was, the lower the COP decreased. As a result, the suction injection could put into use to decrease the discharge temperature.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2015.05.010
spellingShingle Yin Xiang
Sun Shuaihui
Cao Feng
Shu Pengcheng
Research on Performance of Scroll Compressor and System under Suction Injection
Zhileng xuebao
title Research on Performance of Scroll Compressor and System under Suction Injection
title_full Research on Performance of Scroll Compressor and System under Suction Injection
title_fullStr Research on Performance of Scroll Compressor and System under Suction Injection
title_full_unstemmed Research on Performance of Scroll Compressor and System under Suction Injection
title_short Research on Performance of Scroll Compressor and System under Suction Injection
title_sort research on performance of scroll compressor and system under suction injection
url http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2015.05.010
work_keys_str_mv AT yinxiang researchonperformanceofscrollcompressorandsystemundersuctioninjection
AT sunshuaihui researchonperformanceofscrollcompressorandsystemundersuctioninjection
AT caofeng researchonperformanceofscrollcompressorandsystemundersuctioninjection
AT shupengcheng researchonperformanceofscrollcompressorandsystemundersuctioninjection