Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens

Purpose. To evaluate the clinical outcomes after uncomplicated cataract surgery with implantation of an aspheric toric intraocular lens (IOL) during a 6-month follow-up. Methods. Prospective study including 27 consecutive eyes of 18 patients (mean age: 66.1±11.4 years) with a visually significant ca...

Full description

Saved in:
Bibliographic Details
Main Authors: Wojciech Lubiński, Beata Kaźmierczak, Jolanta Gronkowska-Serafin, Karolina Podborączyńska-Jodko
Format: Article
Language:English
Published: Wiley 2016-01-01
Series:Journal of Ophthalmology
Online Access:http://dx.doi.org/10.1155/2016/3257217
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832545461854011392
author Wojciech Lubiński
Beata Kaźmierczak
Jolanta Gronkowska-Serafin
Karolina Podborączyńska-Jodko
author_facet Wojciech Lubiński
Beata Kaźmierczak
Jolanta Gronkowska-Serafin
Karolina Podborączyńska-Jodko
author_sort Wojciech Lubiński
collection DOAJ
description Purpose. To evaluate the clinical outcomes after uncomplicated cataract surgery with implantation of an aspheric toric intraocular lens (IOL) during a 6-month follow-up. Methods. Prospective study including 27 consecutive eyes of 18 patients (mean age: 66.1±11.4 years) with a visually significant cataract and corneal astigmatism ≥ 0.75 D and undergoing uncomplicated cataract surgery with implantation of the Tecnis ZCT toric IOL (Abbott Medical Optics). Visual, refractive, and keratometric outcomes as well as IOL rotation were evaluated during a 6-month follow-up. At the end of the follow-up, patient satisfaction and perception of optical/visual disturbances were also evaluated using a subjective questionnaire. Results. At 6 months after surgery, mean LogMAR uncorrected (UDVA) and corrected distance visual acuity (CDVA) were 0.19±0.12 and 0.14±0.10, respectively. Postoperative UDVA of 20/40 or better was achieved in 92.6% of eyes. Mean refractive cylinder decreased significantly from −3.73±1.96 to −1.42±0.88 D (p<0.001), while keratometric cylinder did not change significantly (p=0.44). Mean absolute IOL rotation was 1.1±2.4°, with values of more than 5° in only 2 eyes (6.9%). Mean patient satisfaction score was 9.70±0.46, using a scale from 0 (not at all satisfied) to 10 (very satisfied). No postoperative optical/visual disturbances were reported. Conclusion. Cataract surgery with implantation of the Tecnis toric IOL is an effective method of refractive correction in eyes with corneal astigmatism due to the good IOL positional stability, providing high levels of patient’s satisfaction.
format Article
id doaj-art-b4705aada0234a42864486038689069e
institution Kabale University
issn 2090-004X
2090-0058
language English
publishDate 2016-01-01
publisher Wiley
record_format Article
series Journal of Ophthalmology
spelling doaj-art-b4705aada0234a42864486038689069e2025-02-03T07:25:45ZengWileyJournal of Ophthalmology2090-004X2090-00582016-01-01201610.1155/2016/32572173257217Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular LensWojciech Lubiński0Beata Kaźmierczak1Jolanta Gronkowska-Serafin2Karolina Podborączyńska-Jodko3Clinic of Ophthalmology, Pomeranian Medical University, 70-111 Szczecin, PolandClinic of Ophthalmology, Pomeranian Medical University, 70-111 Szczecin, PolandClinic of Ophthalmology, Pomeranian Medical University, 70-111 Szczecin, PolandClinic of Ophthalmology, Pomeranian Medical University, 70-111 Szczecin, PolandPurpose. To evaluate the clinical outcomes after uncomplicated cataract surgery with implantation of an aspheric toric intraocular lens (IOL) during a 6-month follow-up. Methods. Prospective study including 27 consecutive eyes of 18 patients (mean age: 66.1±11.4 years) with a visually significant cataract and corneal astigmatism ≥ 0.75 D and undergoing uncomplicated cataract surgery with implantation of the Tecnis ZCT toric IOL (Abbott Medical Optics). Visual, refractive, and keratometric outcomes as well as IOL rotation were evaluated during a 6-month follow-up. At the end of the follow-up, patient satisfaction and perception of optical/visual disturbances were also evaluated using a subjective questionnaire. Results. At 6 months after surgery, mean LogMAR uncorrected (UDVA) and corrected distance visual acuity (CDVA) were 0.19±0.12 and 0.14±0.10, respectively. Postoperative UDVA of 20/40 or better was achieved in 92.6% of eyes. Mean refractive cylinder decreased significantly from −3.73±1.96 to −1.42±0.88 D (p<0.001), while keratometric cylinder did not change significantly (p=0.44). Mean absolute IOL rotation was 1.1±2.4°, with values of more than 5° in only 2 eyes (6.9%). Mean patient satisfaction score was 9.70±0.46, using a scale from 0 (not at all satisfied) to 10 (very satisfied). No postoperative optical/visual disturbances were reported. Conclusion. Cataract surgery with implantation of the Tecnis toric IOL is an effective method of refractive correction in eyes with corneal astigmatism due to the good IOL positional stability, providing high levels of patient’s satisfaction.http://dx.doi.org/10.1155/2016/3257217
spellingShingle Wojciech Lubiński
Beata Kaźmierczak
Jolanta Gronkowska-Serafin
Karolina Podborączyńska-Jodko
Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens
Journal of Ophthalmology
title Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens
title_full Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens
title_fullStr Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens
title_full_unstemmed Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens
title_short Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens
title_sort clinical outcomes after uncomplicated cataract surgery with implantation of the tecnis toric intraocular lens
url http://dx.doi.org/10.1155/2016/3257217
work_keys_str_mv AT wojciechlubinski clinicaloutcomesafteruncomplicatedcataractsurgerywithimplantationofthetecnistoricintraocularlens
AT beatakazmierczak clinicaloutcomesafteruncomplicatedcataractsurgerywithimplantationofthetecnistoricintraocularlens
AT jolantagronkowskaserafin clinicaloutcomesafteruncomplicatedcataractsurgerywithimplantationofthetecnistoricintraocularlens
AT karolinapodboraczynskajodko clinicaloutcomesafteruncomplicatedcataractsurgerywithimplantationofthetecnistoricintraocularlens