Reliability of Schirmer and Phenol Red Thread test value on dry eye patients

Background: The repeatability of the Schirmer test (ST) and Phenol Red Thread test (PRT) has been investigated thoroughly on patients with normal tear function; however, it is limited to dry eye patients. Aim: This study aimed to compare the reliability of the ST and PRT on young adults with dry ey...

Full description

Saved in:
Bibliographic Details
Main Authors: Urvashni Nirghin, Tharuna Govender, Yeshalya Hirachund, Rorisang Mosololi, Hlengiwe Nxumalo, Sumaya Patel, Philani Zwane, Khathutshelo P. Mashige
Format: Article
Language:English
Published: AOSIS 2025-01-01
Series:African Vision and Eye Health
Subjects:
Online Access:https://avehjournal.org/index.php/aveh/article/view/946
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1823858220169428992
author Urvashni Nirghin
Tharuna Govender
Yeshalya Hirachund
Rorisang Mosololi
Hlengiwe Nxumalo
Sumaya Patel
Philani Zwane
Khathutshelo P. Mashige
author_facet Urvashni Nirghin
Tharuna Govender
Yeshalya Hirachund
Rorisang Mosololi
Hlengiwe Nxumalo
Sumaya Patel
Philani Zwane
Khathutshelo P. Mashige
author_sort Urvashni Nirghin
collection DOAJ
description Background: The repeatability of the Schirmer test (ST) and Phenol Red Thread test (PRT) has been investigated thoroughly on patients with normal tear function; however, it is limited to dry eye patients. Aim: This study aimed to compare the reliability of the ST and PRT on young adults with dry eyes. Setting: University of KwaZulu-Natal Eye Clinic. Methods: Forty-eight young adults (mean age 20.65 ± 1.71 years) participated in the study. Preliminary tests excluded dry eye-related abnormalities. Novesin (0.4%) was instilled into the right eye of each participant, followed by the administration of the ST and PRT, 5 min apart, then re-administered after a 10-min interval. The retest was conducted 1 week later with the PRT being performed first to minimise bias. Results: The intra-session correlation of the ST and the PRT was poor (ICC 0.5) and the difference was statistically significant (P  0.05). The inter-session correlation for the PRT was poor (ICC = 0.432) while the ST was moderate (ICC = 0.567) with no statistical difference observed for all parameters (P  0.05). The Bland–Altman plots for intra- and inter-session indicate that 96% of observations fell within the 95% limits of agreement. Conclusion: The ST and PRT demonstrated good intra-session and inter-session reliability, with ST showing better inter-session agreement than the PRT. Contribution: The ST and the PRT provide consistent and reproducible results on dry eye patients when conducted on the same individuals at different time points.
format Article
id doaj-art-b3c974f905bd4b4fb088ef6a4c1149cf
institution Kabale University
issn 2413-3183
2410-1516
language English
publishDate 2025-01-01
publisher AOSIS
record_format Article
series African Vision and Eye Health
spelling doaj-art-b3c974f905bd4b4fb088ef6a4c1149cf2025-02-11T13:22:59ZengAOSISAfrican Vision and Eye Health2413-31832410-15162025-01-01841e1e610.4102/aveh.v84i1.946616Reliability of Schirmer and Phenol Red Thread test value on dry eye patientsUrvashni Nirghin0Tharuna Govender1Yeshalya Hirachund2Rorisang Mosololi3Hlengiwe Nxumalo4Sumaya Patel5Philani Zwane6Khathutshelo P. Mashige7Department of Optometry, Faculty of Health Science, University of KwaZulu-Natal, DurbanDepartment of Optometry, Faculty of Health Science, University of KwaZulu-Natal, DurbanDepartment of Optometry, Faculty of Health Science, University of KwaZulu-Natal, DurbanDepartment of Optometry, Faculty of Health Science, University of KwaZulu-Natal, DurbanDepartment of Optometry, Faculty of Health Science, University of KwaZulu-Natal, DurbanDepartment of Optometry, Faculty of Health Science, University of KwaZulu-Natal, DurbanDepartment of Optometry, Faculty of Health Science, University of KwaZulu-Natal, DurbanDepartment of Optometry, Faculty of Health Science, University of KwaZulu-Natal, DurbanBackground: The repeatability of the Schirmer test (ST) and Phenol Red Thread test (PRT) has been investigated thoroughly on patients with normal tear function; however, it is limited to dry eye patients. Aim: This study aimed to compare the reliability of the ST and PRT on young adults with dry eyes. Setting: University of KwaZulu-Natal Eye Clinic. Methods: Forty-eight young adults (mean age 20.65 ± 1.71 years) participated in the study. Preliminary tests excluded dry eye-related abnormalities. Novesin (0.4%) was instilled into the right eye of each participant, followed by the administration of the ST and PRT, 5 min apart, then re-administered after a 10-min interval. The retest was conducted 1 week later with the PRT being performed first to minimise bias. Results: The intra-session correlation of the ST and the PRT was poor (ICC 0.5) and the difference was statistically significant (P  0.05). The inter-session correlation for the PRT was poor (ICC = 0.432) while the ST was moderate (ICC = 0.567) with no statistical difference observed for all parameters (P  0.05). The Bland–Altman plots for intra- and inter-session indicate that 96% of observations fell within the 95% limits of agreement. Conclusion: The ST and PRT demonstrated good intra-session and inter-session reliability, with ST showing better inter-session agreement than the PRT. Contribution: The ST and the PRT provide consistent and reproducible results on dry eye patients when conducted on the same individuals at different time points.https://avehjournal.org/index.php/aveh/article/view/946dry eyeschirmer testphenol red thread testreliabilityintra-sessionintersession
spellingShingle Urvashni Nirghin
Tharuna Govender
Yeshalya Hirachund
Rorisang Mosololi
Hlengiwe Nxumalo
Sumaya Patel
Philani Zwane
Khathutshelo P. Mashige
Reliability of Schirmer and Phenol Red Thread test value on dry eye patients
African Vision and Eye Health
dry eye
schirmer test
phenol red thread test
reliability
intra-session
intersession
title Reliability of Schirmer and Phenol Red Thread test value on dry eye patients
title_full Reliability of Schirmer and Phenol Red Thread test value on dry eye patients
title_fullStr Reliability of Schirmer and Phenol Red Thread test value on dry eye patients
title_full_unstemmed Reliability of Schirmer and Phenol Red Thread test value on dry eye patients
title_short Reliability of Schirmer and Phenol Red Thread test value on dry eye patients
title_sort reliability of schirmer and phenol red thread test value on dry eye patients
topic dry eye
schirmer test
phenol red thread test
reliability
intra-session
intersession
url https://avehjournal.org/index.php/aveh/article/view/946
work_keys_str_mv AT urvashninirghin reliabilityofschirmerandphenolredthreadtestvalueondryeyepatients
AT tharunagovender reliabilityofschirmerandphenolredthreadtestvalueondryeyepatients
AT yeshalyahirachund reliabilityofschirmerandphenolredthreadtestvalueondryeyepatients
AT rorisangmosololi reliabilityofschirmerandphenolredthreadtestvalueondryeyepatients
AT hlengiwenxumalo reliabilityofschirmerandphenolredthreadtestvalueondryeyepatients
AT sumayapatel reliabilityofschirmerandphenolredthreadtestvalueondryeyepatients
AT philanizwane reliabilityofschirmerandphenolredthreadtestvalueondryeyepatients
AT khathutshelopmashige reliabilityofschirmerandphenolredthreadtestvalueondryeyepatients