PROTOTYPE OF THE WELL WATER CONDUCTIVITY SENSOR SYSTEM BASED MICROCONTROLLER
Electrical conductivity is one of the water quality parameters. The value of conductivity is an early indication of water pollution. Standard of the water conductivity value according to WHO should be less than 400 μS/cm. The prototype of the well-water conductivity sensor system consists of the pow...
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Jurusan Fisika Fakultas Sains Dan Teknologi, Universitas Islam Negeri Maulana Malik Ibrahim Malang
2018-07-01
|
| Series: | Jurnal Neutrino: Jurnal Fisika dan Aplikasinya |
| Subjects: | |
| Online Access: | http://ejournal.uin-malang.ac.id/index.php/NEUTRINO/article/view/4895 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850283690106552320 |
|---|---|
| author | Taufiqurahman Taufiqurahman Ade Agung Harnawan Iwan Sugriwan |
| author_facet | Taufiqurahman Taufiqurahman Ade Agung Harnawan Iwan Sugriwan |
| author_sort | Taufiqurahman Taufiqurahman |
| collection | DOAJ |
| description | Electrical conductivity is one of the water quality parameters. The value of conductivity is an early indication of water pollution. Standard of the water conductivity value according to WHO should be less than 400 μS/cm. The prototype of the well-water conductivity sensor system consists of the power supply, temperature sensor circuit, conductivity sensor circuit, Arduino UNO microcontroller, 16x2 I2C LCD characters and the conversion equation. Therefore, It presents the conductivity value at various temperature and conductivity at 25oC by conversion equation. Furthermore, it measured the conductivity of water within 15.24 - 1031.60 μS/cm with error 0.39 – 21.48 μS/cm and the temperature of water within 20.10 – 50.20oC with error 0.13 – 0.72oC. The test of measurement from 11 sample points in the Pesayangan Martapura and Antasan Senor East Martapura, Banjar, South Kalimantan, Indonesia showed the conductivity of the well-water at the actual temperature was at the range of 128.50 – 364.51 μS/cm and the 161.97 – 364.51 μS/cm at 25oC. |
| format | Article |
| id | doaj-art-b38da196598d4ce88fac73f2e5682a6f |
| institution | OA Journals |
| issn | 1979-6374 2460-5999 |
| language | English |
| publishDate | 2018-07-01 |
| publisher | Jurusan Fisika Fakultas Sains Dan Teknologi, Universitas Islam Negeri Maulana Malik Ibrahim Malang |
| record_format | Article |
| series | Jurnal Neutrino: Jurnal Fisika dan Aplikasinya |
| spelling | doaj-art-b38da196598d4ce88fac73f2e5682a6f2025-08-20T01:47:44ZengJurusan Fisika Fakultas Sains Dan Teknologi, Universitas Islam Negeri Maulana Malik Ibrahim MalangJurnal Neutrino: Jurnal Fisika dan Aplikasinya1979-63742460-59992018-07-01102455110.18860/neu.v10i2.48953908PROTOTYPE OF THE WELL WATER CONDUCTIVITY SENSOR SYSTEM BASED MICROCONTROLLERTaufiqurahman Taufiqurahman0Ade Agung Harnawan1Iwan Sugriwan2Department of Physics, Mathematics and Natural Science of Faculty, University of Lambung MangkuratDepartment of Physics, Mathematics and Natural Science of Faculty, University of Lambung MangkuratDepartment of Physics, Mathematics and Natural Science of Faculty, University of Lambung MangkuratElectrical conductivity is one of the water quality parameters. The value of conductivity is an early indication of water pollution. Standard of the water conductivity value according to WHO should be less than 400 μS/cm. The prototype of the well-water conductivity sensor system consists of the power supply, temperature sensor circuit, conductivity sensor circuit, Arduino UNO microcontroller, 16x2 I2C LCD characters and the conversion equation. Therefore, It presents the conductivity value at various temperature and conductivity at 25oC by conversion equation. Furthermore, it measured the conductivity of water within 15.24 - 1031.60 μS/cm with error 0.39 – 21.48 μS/cm and the temperature of water within 20.10 – 50.20oC with error 0.13 – 0.72oC. The test of measurement from 11 sample points in the Pesayangan Martapura and Antasan Senor East Martapura, Banjar, South Kalimantan, Indonesia showed the conductivity of the well-water at the actual temperature was at the range of 128.50 – 364.51 μS/cm and the 161.97 – 364.51 μS/cm at 25oC.http://ejournal.uin-malang.ac.id/index.php/NEUTRINO/article/view/4895Arduino UNOconductivitytemperaturewell water |
| spellingShingle | Taufiqurahman Taufiqurahman Ade Agung Harnawan Iwan Sugriwan PROTOTYPE OF THE WELL WATER CONDUCTIVITY SENSOR SYSTEM BASED MICROCONTROLLER Jurnal Neutrino: Jurnal Fisika dan Aplikasinya Arduino UNO conductivity temperature well water |
| title | PROTOTYPE OF THE WELL WATER CONDUCTIVITY SENSOR SYSTEM BASED MICROCONTROLLER |
| title_full | PROTOTYPE OF THE WELL WATER CONDUCTIVITY SENSOR SYSTEM BASED MICROCONTROLLER |
| title_fullStr | PROTOTYPE OF THE WELL WATER CONDUCTIVITY SENSOR SYSTEM BASED MICROCONTROLLER |
| title_full_unstemmed | PROTOTYPE OF THE WELL WATER CONDUCTIVITY SENSOR SYSTEM BASED MICROCONTROLLER |
| title_short | PROTOTYPE OF THE WELL WATER CONDUCTIVITY SENSOR SYSTEM BASED MICROCONTROLLER |
| title_sort | prototype of the well water conductivity sensor system based microcontroller |
| topic | Arduino UNO conductivity temperature well water |
| url | http://ejournal.uin-malang.ac.id/index.php/NEUTRINO/article/view/4895 |
| work_keys_str_mv | AT taufiqurahmantaufiqurahman prototypeofthewellwaterconductivitysensorsystembasedmicrocontroller AT adeagungharnawan prototypeofthewellwaterconductivitysensorsystembasedmicrocontroller AT iwansugriwan prototypeofthewellwaterconductivitysensorsystembasedmicrocontroller |