Unbiased Method to Determine Articular Cartilage Thickness Using a Three-Dimensional Model Derived from Laser Scanning: Demonstration on the Distal Femur

Measuring articular cartilage thickness from 3D models developed from laser scans has the potential to offer high accuracy. However, this potential has not been fulfilled, since generating these models requires that the cartilage be removed, and previous methods of removal have led to systematic err...

Full description

Saved in:
Bibliographic Details
Main Authors: Valentina Campanelli, Maury L. Hull
Format: Article
Language:English
Published: MDPI AG 2024-11-01
Series:Bioengineering
Subjects:
Online Access:https://www.mdpi.com/2306-5354/11/11/1118
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850145753448579072
author Valentina Campanelli
Maury L. Hull
author_facet Valentina Campanelli
Maury L. Hull
author_sort Valentina Campanelli
collection DOAJ
description Measuring articular cartilage thickness from 3D models developed from laser scans has the potential to offer high accuracy. However, this potential has not been fulfilled, since generating these models requires that the cartilage be removed, and previous methods of removal have led to systematic errors (i.e., bias) due to changes in the overall dimensions of the underlying bone. The objectives were to present a new method for removing articular cartilage, quantify the bias error, and demonstrate the method on the distal (i.e., 0° flexion) and posterior (i.e., 90° flexion) articular surfaces of example human femurs. The method consisted of creating a 3D articular cartilage model from high-accuracy (i.e., precision = 0.087 mm) laser scans before and after cartilage removal using dermestid beetles to remove the cartilage. Fiducial markers were used to minimize errors in registering surfaces generated from the two laser scans. To demonstrate the method, the cartilage thickness was computed in distal and posterior subregions of each femoral condyle for three example cadaveric specimens. The use of dermestid beetles did not introduce measurable bias, and the previously reported precision achieved in 3D cartilage models with the laser scanner was 0.13 mm. For the different subregions, the cartilage thickness ranged from 1.5 mm to 2.0 mm. A method of imaging by means of laser scanning, cartilage removal by means of dermestid beetles, and 3D model registration by means of fiducial markers ensured that cartilage thickness on the articular surface of the long bones of the knee was determined with negligible bias and a precision of 0.13 mm. With this method, the potential to measure cartilage thickness with high accuracy based on 3D models developed from laser scans can be fully realized.
format Article
id doaj-art-b388d0890e8f4ff9a727ab5d4a63b06d
institution OA Journals
issn 2306-5354
language English
publishDate 2024-11-01
publisher MDPI AG
record_format Article
series Bioengineering
spelling doaj-art-b388d0890e8f4ff9a727ab5d4a63b06d2025-08-20T02:28:01ZengMDPI AGBioengineering2306-53542024-11-011111111810.3390/bioengineering11111118Unbiased Method to Determine Articular Cartilage Thickness Using a Three-Dimensional Model Derived from Laser Scanning: Demonstration on the Distal FemurValentina Campanelli0Maury L. Hull1THINK Surgical, Fremont, CA 94538, USADepartment of Biomedical Engineering, University of California Davis, Davis, CA 95616, USAMeasuring articular cartilage thickness from 3D models developed from laser scans has the potential to offer high accuracy. However, this potential has not been fulfilled, since generating these models requires that the cartilage be removed, and previous methods of removal have led to systematic errors (i.e., bias) due to changes in the overall dimensions of the underlying bone. The objectives were to present a new method for removing articular cartilage, quantify the bias error, and demonstrate the method on the distal (i.e., 0° flexion) and posterior (i.e., 90° flexion) articular surfaces of example human femurs. The method consisted of creating a 3D articular cartilage model from high-accuracy (i.e., precision = 0.087 mm) laser scans before and after cartilage removal using dermestid beetles to remove the cartilage. Fiducial markers were used to minimize errors in registering surfaces generated from the two laser scans. To demonstrate the method, the cartilage thickness was computed in distal and posterior subregions of each femoral condyle for three example cadaveric specimens. The use of dermestid beetles did not introduce measurable bias, and the previously reported precision achieved in 3D cartilage models with the laser scanner was 0.13 mm. For the different subregions, the cartilage thickness ranged from 1.5 mm to 2.0 mm. A method of imaging by means of laser scanning, cartilage removal by means of dermestid beetles, and 3D model registration by means of fiducial markers ensured that cartilage thickness on the articular surface of the long bones of the knee was determined with negligible bias and a precision of 0.13 mm. With this method, the potential to measure cartilage thickness with high accuracy based on 3D models developed from laser scans can be fully realized.https://www.mdpi.com/2306-5354/11/11/1118articular cartilagelaser scannercomputed tomographyfiducial markersdermestid beetles
spellingShingle Valentina Campanelli
Maury L. Hull
Unbiased Method to Determine Articular Cartilage Thickness Using a Three-Dimensional Model Derived from Laser Scanning: Demonstration on the Distal Femur
Bioengineering
articular cartilage
laser scanner
computed tomography
fiducial markers
dermestid beetles
title Unbiased Method to Determine Articular Cartilage Thickness Using a Three-Dimensional Model Derived from Laser Scanning: Demonstration on the Distal Femur
title_full Unbiased Method to Determine Articular Cartilage Thickness Using a Three-Dimensional Model Derived from Laser Scanning: Demonstration on the Distal Femur
title_fullStr Unbiased Method to Determine Articular Cartilage Thickness Using a Three-Dimensional Model Derived from Laser Scanning: Demonstration on the Distal Femur
title_full_unstemmed Unbiased Method to Determine Articular Cartilage Thickness Using a Three-Dimensional Model Derived from Laser Scanning: Demonstration on the Distal Femur
title_short Unbiased Method to Determine Articular Cartilage Thickness Using a Three-Dimensional Model Derived from Laser Scanning: Demonstration on the Distal Femur
title_sort unbiased method to determine articular cartilage thickness using a three dimensional model derived from laser scanning demonstration on the distal femur
topic articular cartilage
laser scanner
computed tomography
fiducial markers
dermestid beetles
url https://www.mdpi.com/2306-5354/11/11/1118
work_keys_str_mv AT valentinacampanelli unbiasedmethodtodeterminearticularcartilagethicknessusingathreedimensionalmodelderivedfromlaserscanningdemonstrationonthedistalfemur
AT maurylhull unbiasedmethodtodeterminearticularcartilagethicknessusingathreedimensionalmodelderivedfromlaserscanningdemonstrationonthedistalfemur