ANALISIS EFEKTIVITAS PENGELOLAAN AIR LIMBAH RUMAH SAKIT BHAYANGKARA KUPANG

Hospitals are significant producers of liquid waste that have the potential to pollute the environment if not properly managed. Hospital wastewater contains organic and inorganic substances, pathogenic microorganisms, and hazardous chemicals. This study aims to evaluate the effectiveness of the Was...

Full description

Saved in:
Bibliographic Details
Main Authors: Reinaldy Endhrico Mengge, Susana Maria Suratma, Amandus Jong Tallo
Format: Article
Language:English
Published: STKIP PGRI Situbondo 2025-05-01
Series:Edusaintek
Subjects:
Online Access:https://journalstkippgrisitubondo.ac.id/index.php/EDUSAINTEK/article/view/1789
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850141244477407232
author Reinaldy Endhrico Mengge
Susana Maria Suratma
Amandus Jong Tallo
author_facet Reinaldy Endhrico Mengge
Susana Maria Suratma
Amandus Jong Tallo
author_sort Reinaldy Endhrico Mengge
collection DOAJ
description Hospitals are significant producers of liquid waste that have the potential to pollute the environment if not properly managed. Hospital wastewater contains organic and inorganic substances, pathogenic microorganisms, and hazardous chemicals. This study aims to evaluate the effectiveness of the Wastewater Treatment Plant (WWTP) at Bhayangkara Hospital Kupang based on chemical and microbiological parameters, including pH, temperature, Biological Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Total Suspended Solids (TSS), Total Dissolved Solids (TDS), oil and grease, and total coliform. The study uses a descriptive qualitative method with secondary data analysis from laboratory results. The results show that all parameters are below the threshold of environmental quality standards set by the Ministry of Environment Regulation No. 5 of 2014, with values for: pH (7.255), temperature (28°C), BOD (38.7 mg/L), COD (76 mg/L), TSS (0.06 mg/L), TDS (363 mg/L), oil and grease (0.016 mg/L), and total coliform (438/100 mL). These results indicate that the WWTP at Bhayangkara Hospital Kupang operates effectively in treating wastewater, making the discharged wastewater suitable for disposal into the environment and in compliance with the established quality standards.
format Article
id doaj-art-b3200daf7beb489ba0d9872cf1f7278a
institution OA Journals
issn 1858-005X
2655-3392
language English
publishDate 2025-05-01
publisher STKIP PGRI Situbondo
record_format Article
series Edusaintek
spelling doaj-art-b3200daf7beb489ba0d9872cf1f7278a2025-08-20T02:29:30ZengSTKIP PGRI SitubondoEdusaintek1858-005X2655-33922025-05-0112310.47668/edusaintek.v12i3.1789ANALISIS EFEKTIVITAS PENGELOLAAN AIR LIMBAH RUMAH SAKIT BHAYANGKARA KUPANGReinaldy Endhrico Mengge0Susana Maria Suratma1Amandus Jong Tallo2Program Studi Teknik Perancangan Irigasi dan Penanganan Pantai Jurusan Teknik Sipil Politeknik Negeri Kupang, IndonesiaProgram Studi Teknik Perancangan Irigasi dan Penanganan Pantai Jurusan Teknik Sipil Politeknik Negeri Kupang, IndonesiaPerencanaan Wilayah dan Kota Politeknik Negeri Kupang, Indonesia Hospitals are significant producers of liquid waste that have the potential to pollute the environment if not properly managed. Hospital wastewater contains organic and inorganic substances, pathogenic microorganisms, and hazardous chemicals. This study aims to evaluate the effectiveness of the Wastewater Treatment Plant (WWTP) at Bhayangkara Hospital Kupang based on chemical and microbiological parameters, including pH, temperature, Biological Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Total Suspended Solids (TSS), Total Dissolved Solids (TDS), oil and grease, and total coliform. The study uses a descriptive qualitative method with secondary data analysis from laboratory results. The results show that all parameters are below the threshold of environmental quality standards set by the Ministry of Environment Regulation No. 5 of 2014, with values for: pH (7.255), temperature (28°C), BOD (38.7 mg/L), COD (76 mg/L), TSS (0.06 mg/L), TDS (363 mg/L), oil and grease (0.016 mg/L), and total coliform (438/100 mL). These results indicate that the WWTP at Bhayangkara Hospital Kupang operates effectively in treating wastewater, making the discharged wastewater suitable for disposal into the environment and in compliance with the established quality standards. https://journalstkippgrisitubondo.ac.id/index.php/EDUSAINTEK/article/view/1789hospital wastewaterKupangchemical parameters
spellingShingle Reinaldy Endhrico Mengge
Susana Maria Suratma
Amandus Jong Tallo
ANALISIS EFEKTIVITAS PENGELOLAAN AIR LIMBAH RUMAH SAKIT BHAYANGKARA KUPANG
Edusaintek
hospital wastewater
Kupang
chemical parameters
title ANALISIS EFEKTIVITAS PENGELOLAAN AIR LIMBAH RUMAH SAKIT BHAYANGKARA KUPANG
title_full ANALISIS EFEKTIVITAS PENGELOLAAN AIR LIMBAH RUMAH SAKIT BHAYANGKARA KUPANG
title_fullStr ANALISIS EFEKTIVITAS PENGELOLAAN AIR LIMBAH RUMAH SAKIT BHAYANGKARA KUPANG
title_full_unstemmed ANALISIS EFEKTIVITAS PENGELOLAAN AIR LIMBAH RUMAH SAKIT BHAYANGKARA KUPANG
title_short ANALISIS EFEKTIVITAS PENGELOLAAN AIR LIMBAH RUMAH SAKIT BHAYANGKARA KUPANG
title_sort analisis efektivitas pengelolaan air limbah rumah sakit bhayangkara kupang
topic hospital wastewater
Kupang
chemical parameters
url https://journalstkippgrisitubondo.ac.id/index.php/EDUSAINTEK/article/view/1789
work_keys_str_mv AT reinaldyendhricomengge analisisefektivitaspengelolaanairlimbahrumahsakitbhayangkarakupang
AT susanamariasuratma analisisefektivitaspengelolaanairlimbahrumahsakitbhayangkarakupang
AT amandusjongtallo analisisefektivitaspengelolaanairlimbahrumahsakitbhayangkarakupang