WaveOne Gold Reciprocating Instruments in Clinical Practice (Part 1)
The design features of the WaveOne Gold Primary system and some of its previous analogswill be discussed since they allow channel processing using only one file in 80-85% of clinical cases. In the second part of the article, we will discuss when it is still necessary to use more than one WaveOne Gol...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Article |
| Language: | Russian |
| Published: |
LLC "Endo Press"
2021-05-01
|
| Series: | Эндодонтия Today |
| Subjects: | |
| Online Access: | https://www.endodont.ru/jour/article/view/941 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850031705529778176 |
|---|---|
| author | P. van der Vyver M. Vorster |
| author_facet | P. van der Vyver M. Vorster |
| author_sort | P. van der Vyver |
| collection | DOAJ |
| description | The design features of the WaveOne Gold Primary system and some of its previous analogswill be discussed since they allow channel processing using only one file in 80-85% of clinical cases. In the second part of the article, we will discuss when it is still necessary to use more than one WaveOne Gold instrument with examples of specific complex clinical cases with curved canals. In the end, we will pay attention to the peculiarities of processing very large canals, which are also difficult for the doctor. |
| format | Article |
| id | doaj-art-b2456b4a601f432eb5da9684320efdd2 |
| institution | DOAJ |
| issn | 1683-2981 1726-7242 |
| language | Russian |
| publishDate | 2021-05-01 |
| publisher | LLC "Endo Press" |
| record_format | Article |
| series | Эндодонтия Today |
| spelling | doaj-art-b2456b4a601f432eb5da9684320efdd22025-08-20T02:58:54ZrusLLC "Endo Press"Эндодонтия Today1683-29811726-72422021-05-01184323510.36377/1683-2981-2020-18-4-32-35892WaveOne Gold Reciprocating Instruments in Clinical Practice (Part 1)P. van der Vyver0M. Vorster1University of PretoriaUniversity of PretoriaThe design features of the WaveOne Gold Primary system and some of its previous analogswill be discussed since they allow channel processing using only one file in 80-85% of clinical cases. In the second part of the article, we will discuss when it is still necessary to use more than one WaveOne Gold instrument with examples of specific complex clinical cases with curved canals. In the end, we will pay attention to the peculiarities of processing very large canals, which are also difficult for the doctor.https://www.endodont.ru/jour/article/view/941endodontic instrumentswaveone goldreciprocal instruments |
| spellingShingle | P. van der Vyver M. Vorster WaveOne Gold Reciprocating Instruments in Clinical Practice (Part 1) Эндодонтия Today endodontic instruments waveone gold reciprocal instruments |
| title | WaveOne Gold Reciprocating Instruments in Clinical Practice (Part 1) |
| title_full | WaveOne Gold Reciprocating Instruments in Clinical Practice (Part 1) |
| title_fullStr | WaveOne Gold Reciprocating Instruments in Clinical Practice (Part 1) |
| title_full_unstemmed | WaveOne Gold Reciprocating Instruments in Clinical Practice (Part 1) |
| title_short | WaveOne Gold Reciprocating Instruments in Clinical Practice (Part 1) |
| title_sort | waveone gold reciprocating instruments in clinical practice part 1 |
| topic | endodontic instruments waveone gold reciprocal instruments |
| url | https://www.endodont.ru/jour/article/view/941 |
| work_keys_str_mv | AT pvandervyver waveonegoldreciprocatinginstrumentsinclinicalpracticepart1 AT mvorster waveonegoldreciprocatinginstrumentsinclinicalpracticepart1 |