The Arrangement Concept and the Energy Potential of the Vapor Compression Heat and Cooling Supply Based on a Binary Low-Temperature Source

The combined use of low-potential soil heat and air flows in heat pump heat supply systems allows for its regulated redistribution in the processes of customers’ consumption. Herewith, the intensity of energy extraction by the soil heat exchanger decreases, excess heat is accumulated with a decrease...

Full description

Saved in:
Bibliographic Details
Main Authors: V. D. Petrash, O. I. Khomenko, D. V. Basist, A. Ujma
Format: Article
Language:Russian
Published: Belarusian National Technical University 2022-10-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/2200
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849241652490665984
author V. D. Petrash
O. I. Khomenko
D. V. Basist
A. Ujma
author_facet V. D. Petrash
O. I. Khomenko
D. V. Basist
A. Ujma
author_sort V. D. Petrash
collection DOAJ
description The combined use of low-potential soil heat and air flows in heat pump heat supply systems allows for its regulated redistribution in the processes of customers’ consumption. Herewith, the intensity of energy extraction by the soil heat exchanger decreases, excess heat is accumulated with a decrease in the depth of wells, and the costs of installing and operating probe heat exchangers are also reduced. An improved version of the conceptual arrangement of a vapor compression system for heat and cool supply of buildings based on the integrated heat of soil and ventilation air has been developed. Its distinguished features are the possibility of automatic redistribution of generated heat flows in the subsystems of customers’ heat consumption and accumulation of excess part in the soil mass. When the system is operating in the warm season with the extraction of heat only for hot water supply, there is a more intensive accumulation of excess heat of the ventilation air in the soil mass, which restores its temperature in the accumulation mode for further use with the coming of the heating period. Multifactor analytical dependences of the heat flows of the main equipment have been established, taking into account the initial parameters and operating conditions of the structural subsystems for the extraction, transformation and consumption of heat, which are the basis for determining the energy potential of vapor compression heat and cold supply using a binary low-temperature source.
format Article
id doaj-art-b133791f269e4daeb534bca345c4d993
institution Kabale University
issn 1029-7448
2414-0341
language Russian
publishDate 2022-10-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj-art-b133791f269e4daeb534bca345c4d9932025-08-20T04:00:04ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412022-10-0165543645010.21122/1029-7448-2023-65-5-436-4501824The Arrangement Concept and the Energy Potential of the Vapor Compression Heat and Cooling Supply Based on a Binary Low-Temperature SourceV. D. Petrash0O. I. Khomenko1D. V. Basist2A. Ujma3Odessa State Academy of Civil Engineering and ArchitectureOdessa State Academy of Civil Engineering and Architecture State Academy of Civil Engineering and ArchitectureOdessa State Academy of Civil Engineering and ArchitectureCzęstochowa University of TechnologyThe combined use of low-potential soil heat and air flows in heat pump heat supply systems allows for its regulated redistribution in the processes of customers’ consumption. Herewith, the intensity of energy extraction by the soil heat exchanger decreases, excess heat is accumulated with a decrease in the depth of wells, and the costs of installing and operating probe heat exchangers are also reduced. An improved version of the conceptual arrangement of a vapor compression system for heat and cool supply of buildings based on the integrated heat of soil and ventilation air has been developed. Its distinguished features are the possibility of automatic redistribution of generated heat flows in the subsystems of customers’ heat consumption and accumulation of excess part in the soil mass. When the system is operating in the warm season with the extraction of heat only for hot water supply, there is a more intensive accumulation of excess heat of the ventilation air in the soil mass, which restores its temperature in the accumulation mode for further use with the coming of the heating period. Multifactor analytical dependences of the heat flows of the main equipment have been established, taking into account the initial parameters and operating conditions of the structural subsystems for the extraction, transformation and consumption of heat, which are the basis for determining the energy potential of vapor compression heat and cold supply using a binary low-temperature source.https://energy.bntu.by/jour/article/view/2200low-temperature heat sourcesheat supplyheat pumpconversion factor
spellingShingle V. D. Petrash
O. I. Khomenko
D. V. Basist
A. Ujma
The Arrangement Concept and the Energy Potential of the Vapor Compression Heat and Cooling Supply Based on a Binary Low-Temperature Source
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
low-temperature heat sources
heat supply
heat pump
conversion factor
title The Arrangement Concept and the Energy Potential of the Vapor Compression Heat and Cooling Supply Based on a Binary Low-Temperature Source
title_full The Arrangement Concept and the Energy Potential of the Vapor Compression Heat and Cooling Supply Based on a Binary Low-Temperature Source
title_fullStr The Arrangement Concept and the Energy Potential of the Vapor Compression Heat and Cooling Supply Based on a Binary Low-Temperature Source
title_full_unstemmed The Arrangement Concept and the Energy Potential of the Vapor Compression Heat and Cooling Supply Based on a Binary Low-Temperature Source
title_short The Arrangement Concept and the Energy Potential of the Vapor Compression Heat and Cooling Supply Based on a Binary Low-Temperature Source
title_sort arrangement concept and the energy potential of the vapor compression heat and cooling supply based on a binary low temperature source
topic low-temperature heat sources
heat supply
heat pump
conversion factor
url https://energy.bntu.by/jour/article/view/2200
work_keys_str_mv AT vdpetrash thearrangementconceptandtheenergypotentialofthevaporcompressionheatandcoolingsupplybasedonabinarylowtemperaturesource
AT oikhomenko thearrangementconceptandtheenergypotentialofthevaporcompressionheatandcoolingsupplybasedonabinarylowtemperaturesource
AT dvbasist thearrangementconceptandtheenergypotentialofthevaporcompressionheatandcoolingsupplybasedonabinarylowtemperaturesource
AT aujma thearrangementconceptandtheenergypotentialofthevaporcompressionheatandcoolingsupplybasedonabinarylowtemperaturesource
AT vdpetrash arrangementconceptandtheenergypotentialofthevaporcompressionheatandcoolingsupplybasedonabinarylowtemperaturesource
AT oikhomenko arrangementconceptandtheenergypotentialofthevaporcompressionheatandcoolingsupplybasedonabinarylowtemperaturesource
AT dvbasist arrangementconceptandtheenergypotentialofthevaporcompressionheatandcoolingsupplybasedonabinarylowtemperaturesource
AT aujma arrangementconceptandtheenergypotentialofthevaporcompressionheatandcoolingsupplybasedonabinarylowtemperaturesource