Study on Dynamic Changes of Dew Point Air Temperature at the Attachment Layer of Radiant Ceiling
The variation in dew point temperature at the attached layer of radiant ceiling was examined when the number of indoor occupants was increased in this study. Through numerical simulation and linear regression performed by SAS software, the influence of various factors on the air dew point temperatur...
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Journal of Refrigeration Magazines Agency Co., Ltd.
2019-01-01
|
| Series: | Zhileng xuebao |
| Subjects: | |
| Online Access: | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2019.03.151 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849707598085881856 |
|---|---|
| author | Jin Wufeng Bi Chen Gao Pan Jia Lizhi Wang Zhiqiang |
| author_facet | Jin Wufeng Bi Chen Gao Pan Jia Lizhi Wang Zhiqiang |
| author_sort | Jin Wufeng |
| collection | DOAJ |
| description | The variation in dew point temperature at the attached layer of radiant ceiling was examined when the number of indoor occupants was increased in this study. Through numerical simulation and linear regression performed by SAS software, the influence of various factors on the air dew point temperature of the attached layer was obtained. Furthermore, the dynamic relationship between the main influence factor and the dew point temperature of the attached layer was obtained, and the experimental data was used to verify the simulation and calculation results. The results show that the air dew point temperature increased by approximately 1.5 °C and 2.5 °C when adding two and four people, respectively. The distance between the personnel and the attached layer, as well as the number of personnel have a great influence on the dew point temperature of the attached layer, with the contribution rate accounting for 43% and 48%, respectively; and the contribution from the other impact factors can be ignored. The dynamic change of the air dew point temperature of the attached layer is in the form of a negative exponential function. The influence of the distance between the attached layer and the personnel on the dew point temperature of the attached layer is greater than that of the increase in personnel number. |
| format | Article |
| id | doaj-art-af4bac28cd464ef68d5df0ebb2cd81a1 |
| institution | DOAJ |
| issn | 0253-4339 |
| language | zho |
| publishDate | 2019-01-01 |
| publisher | Journal of Refrigeration Magazines Agency Co., Ltd. |
| record_format | Article |
| series | Zhileng xuebao |
| spelling | doaj-art-af4bac28cd464ef68d5df0ebb2cd81a12025-08-20T03:15:53ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392019-01-014066510242Study on Dynamic Changes of Dew Point Air Temperature at the Attachment Layer of Radiant CeilingJin WufengBi ChenGao PanJia LizhiWang ZhiqiangThe variation in dew point temperature at the attached layer of radiant ceiling was examined when the number of indoor occupants was increased in this study. Through numerical simulation and linear regression performed by SAS software, the influence of various factors on the air dew point temperature of the attached layer was obtained. Furthermore, the dynamic relationship between the main influence factor and the dew point temperature of the attached layer was obtained, and the experimental data was used to verify the simulation and calculation results. The results show that the air dew point temperature increased by approximately 1.5 °C and 2.5 °C when adding two and four people, respectively. The distance between the personnel and the attached layer, as well as the number of personnel have a great influence on the dew point temperature of the attached layer, with the contribution rate accounting for 43% and 48%, respectively; and the contribution from the other impact factors can be ignored. The dynamic change of the air dew point temperature of the attached layer is in the form of a negative exponential function. The influence of the distance between the attached layer and the personnel on the dew point temperature of the attached layer is greater than that of the increase in personnel number.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2019.03.151radiant ceilingdew point temperatureregression analysisfactor contribution rate |
| spellingShingle | Jin Wufeng Bi Chen Gao Pan Jia Lizhi Wang Zhiqiang Study on Dynamic Changes of Dew Point Air Temperature at the Attachment Layer of Radiant Ceiling Zhileng xuebao radiant ceiling dew point temperature regression analysis factor contribution rate |
| title | Study on Dynamic Changes of Dew Point Air Temperature at the Attachment Layer of Radiant Ceiling |
| title_full | Study on Dynamic Changes of Dew Point Air Temperature at the Attachment Layer of Radiant Ceiling |
| title_fullStr | Study on Dynamic Changes of Dew Point Air Temperature at the Attachment Layer of Radiant Ceiling |
| title_full_unstemmed | Study on Dynamic Changes of Dew Point Air Temperature at the Attachment Layer of Radiant Ceiling |
| title_short | Study on Dynamic Changes of Dew Point Air Temperature at the Attachment Layer of Radiant Ceiling |
| title_sort | study on dynamic changes of dew point air temperature at the attachment layer of radiant ceiling |
| topic | radiant ceiling dew point temperature regression analysis factor contribution rate |
| url | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2019.03.151 |
| work_keys_str_mv | AT jinwufeng studyondynamicchangesofdewpointairtemperatureattheattachmentlayerofradiantceiling AT bichen studyondynamicchangesofdewpointairtemperatureattheattachmentlayerofradiantceiling AT gaopan studyondynamicchangesofdewpointairtemperatureattheattachmentlayerofradiantceiling AT jializhi studyondynamicchangesofdewpointairtemperatureattheattachmentlayerofradiantceiling AT wangzhiqiang studyondynamicchangesofdewpointairtemperatureattheattachmentlayerofradiantceiling |