Reproducibility of Areal Topography Parameters Obtained by Atomic Force Microscope
In the context of quality management and Industry 5.0, reproducibility is a critical indicator of the ability to achieve consistent and predictable results in laboratories, research, as well as in systems and processes. Reproducibility is also an indispensable component of measurement uncertainty, w...
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
University North
2025-01-01
|
| Series: | Tehnički Glasnik |
| Subjects: | |
| Online Access: | https://hrcak.srce.hr/file/478121 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850191977834872832 |
|---|---|
| author | Andrej Razumić Biserka Runje Zdenka Keran Zvonko Trzun Daniel Pugar |
| author_facet | Andrej Razumić Biserka Runje Zdenka Keran Zvonko Trzun Daniel Pugar |
| author_sort | Andrej Razumić |
| collection | DOAJ |
| description | In the context of quality management and Industry 5.0, reproducibility is a critical indicator of the ability to achieve consistent and predictable results in laboratories, research, as well as in systems and processes. Reproducibility is also an indispensable component of measurement uncertainty, which quantifies the precision of measurement results. To standardize the measurement procedure for surface topography parameters obtained using atomic force microscope (AFM) and to establish the accuracy and precision of measurement results, an analysis of repeatability and reproducibility was conducted in accordance with the ISO 5725-2:2019 standard, Accuracy (trueness and precision) of measurement methods and results – Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method. Measurements were performed on two AFM standards and a steel sample. The research was conducted over the course of one year and repeated after four years using the same samples. |
| format | Article |
| id | doaj-art-aeaec1417c794920aa528b34fe7d32ea |
| institution | OA Journals |
| issn | 1846-6168 1848-5588 |
| language | English |
| publishDate | 2025-01-01 |
| publisher | University North |
| record_format | Article |
| series | Tehnički Glasnik |
| spelling | doaj-art-aeaec1417c794920aa528b34fe7d32ea2025-08-20T02:14:43ZengUniversity NorthTehnički Glasnik1846-61681848-55882025-01-0119si11610.31803/tg-20250324183037Reproducibility of Areal Topography Parameters Obtained by Atomic Force MicroscopeAndrej Razumić0Biserka Runje1Zdenka Keran2Zvonko Trzun3Daniel Pugar4Department of Polytechnics, Dr. Franjo Tuđman Defense and Security University, Ilica 256b, 10000 Zagreb, CroatiaFaculty of Mechanical Engineering and Naval Architecture, University of Zagreb, Ivana Lučića 5, 10000 Zagreb, CroatiaFaculty of Mechanical Engineering and Naval Architecture, University of Zagreb, Ivana Lučića 5, 10000 Zagreb, CroatiaDepartment of Polytechnics, Dr. Franjo Tuđman Defense and Security University, Ilica 256b, 10000 Zagreb, CroatiaDepartment of Polytechnics, Dr. Franjo Tuđman Defense and Security University, Ilica 256b, 10000 Zagreb, CroatiaIn the context of quality management and Industry 5.0, reproducibility is a critical indicator of the ability to achieve consistent and predictable results in laboratories, research, as well as in systems and processes. Reproducibility is also an indispensable component of measurement uncertainty, which quantifies the precision of measurement results. To standardize the measurement procedure for surface topography parameters obtained using atomic force microscope (AFM) and to establish the accuracy and precision of measurement results, an analysis of repeatability and reproducibility was conducted in accordance with the ISO 5725-2:2019 standard, Accuracy (trueness and precision) of measurement methods and results – Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method. Measurements were performed on two AFM standards and a steel sample. The research was conducted over the course of one year and repeated after four years using the same samples.https://hrcak.srce.hr/file/478121areal topography parametersatomic force microscopeIndustry 5.0quality managementreproducibility |
| spellingShingle | Andrej Razumić Biserka Runje Zdenka Keran Zvonko Trzun Daniel Pugar Reproducibility of Areal Topography Parameters Obtained by Atomic Force Microscope Tehnički Glasnik areal topography parameters atomic force microscope Industry 5.0 quality management reproducibility |
| title | Reproducibility of Areal Topography Parameters Obtained by Atomic Force Microscope |
| title_full | Reproducibility of Areal Topography Parameters Obtained by Atomic Force Microscope |
| title_fullStr | Reproducibility of Areal Topography Parameters Obtained by Atomic Force Microscope |
| title_full_unstemmed | Reproducibility of Areal Topography Parameters Obtained by Atomic Force Microscope |
| title_short | Reproducibility of Areal Topography Parameters Obtained by Atomic Force Microscope |
| title_sort | reproducibility of areal topography parameters obtained by atomic force microscope |
| topic | areal topography parameters atomic force microscope Industry 5.0 quality management reproducibility |
| url | https://hrcak.srce.hr/file/478121 |
| work_keys_str_mv | AT andrejrazumic reproducibilityofarealtopographyparametersobtainedbyatomicforcemicroscope AT biserkarunje reproducibilityofarealtopographyparametersobtainedbyatomicforcemicroscope AT zdenkakeran reproducibilityofarealtopographyparametersobtainedbyatomicforcemicroscope AT zvonkotrzun reproducibilityofarealtopographyparametersobtainedbyatomicforcemicroscope AT danielpugar reproducibilityofarealtopographyparametersobtainedbyatomicforcemicroscope |