Clinical Value of Low-Dose Spiral CT Combined with Serum CEA in the Differential Diagnosis of Early Lung Cancer

Jianguo Jin,1 Liping Wu2 1Department of Radiology, First People’s Hospital of Linping District, Hangzhou, Zhejiang, People’s Republic of China; 2Department of General Geriatrics, Integrated Traditional Chinese, Hangzhou of Linping District, Hangzhou, Zhejiang, People’s Republic of ChinaCorrespondenc...

Full description

Saved in:
Bibliographic Details
Main Authors: Jin J, Wu L
Format: Article
Language:English
Published: Dove Medical Press 2025-07-01
Series:Cancer Management and Research
Subjects:
Online Access:https://www.dovepress.com/clinical-value-of-low-dose-spiral-ct-combined-with-serum-cea-in-the-di-peer-reviewed-fulltext-article-CMAR
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849718570366271488
author Jin J
Wu L
author_facet Jin J
Wu L
author_sort Jin J
collection DOAJ
description Jianguo Jin,1 Liping Wu2 1Department of Radiology, First People’s Hospital of Linping District, Hangzhou, Zhejiang, People’s Republic of China; 2Department of General Geriatrics, Integrated Traditional Chinese, Hangzhou of Linping District, Hangzhou, Zhejiang, People’s Republic of ChinaCorrespondence: Liping Wu, Department of General Geriatrics, Integrated Traditional Chinese, Hangzhou of Linping District, No. 369 of Yingbin Road, Nanyuan Street, Linping District, Hangzhou, Zhejiang, 311100, People’s Republic of China, Tel +86– 18072889033, Email 13376819518@163.comPurpose: Early detection of lung cancer is critical to improving prognosis, yet current screening methods such as low-dose spiral CT and serum CEA each have diagnostic limitations. This study aims to analyze the clinical value of low-dose spiral CT combined with serum CEA in the differential diagnosis of early lung cancer.Materials and Methods: In this retrospective study, 62 patients diagnosed with early lung cancer in our hospital from April 2022 to October 2023 were selected as the case group, and 50 patients diagnosed with benign pulmonary lesions during the same period were selected as the control group. Data from low-dose spiral CT and serum CEA levels were compared. The efficacy of low-dose spiral CT alone, serum CEA alone, and the combination of both in discriminating early lung cancer was assessed using ROC curves.Results: Low-dose spiral CT showed a sensitivity of 77.42%, a specificity of 94.00%, and an AUC of 0.8571 (95% CI: 0.7832– 0.9310) in detecting early lung cancer. Serum CEA levels were significantly higher in the case group compared to the control group (P< 0.05). Serum CEA yielded an AUC of 0.8661 (95% CI: 0.7964– 0.9359) in distinguishing early lung cancer (P< 0.0001). Low-dose spiral CT combined with serum CEA detection achieved an AUC of 0.9137 (95% CI: 0.8624– 0.9650), significantly increasing the early lung cancer detection rate from 82.26% to 95.16% (P< 0.05).Conclusion: Patients with early lung cancer show distinct alterations in low-dose spiral CT signs, and their serum CEA levels demonstrate a notable increase compared with those with benign pulmonary lesions. The combination of low-dose spiral CT with serum CEA can be considered in the discrimination of early lung cancer, which can markedly enhance the positive detection rate while maintaining a minimal rise in false-positive rates.Keywords: low-dose spiral CT, serum carcinoembryonic antigen, early lung cancer, combined detection, discriminative value
format Article
id doaj-art-ae4c93b0d50d49759ec5fee4eab2492f
institution DOAJ
issn 1179-1322
language English
publishDate 2025-07-01
publisher Dove Medical Press
record_format Article
series Cancer Management and Research
spelling doaj-art-ae4c93b0d50d49759ec5fee4eab2492f2025-08-20T03:12:20ZengDove Medical PressCancer Management and Research1179-13222025-07-01Volume 17Issue 114211432104901Clinical Value of Low-Dose Spiral CT Combined with Serum CEA in the Differential Diagnosis of Early Lung CancerJin J0Wu L1RadiologyGeneral GeriatricsJianguo Jin,1 Liping Wu2 1Department of Radiology, First People’s Hospital of Linping District, Hangzhou, Zhejiang, People’s Republic of China; 2Department of General Geriatrics, Integrated Traditional Chinese, Hangzhou of Linping District, Hangzhou, Zhejiang, People’s Republic of ChinaCorrespondence: Liping Wu, Department of General Geriatrics, Integrated Traditional Chinese, Hangzhou of Linping District, No. 369 of Yingbin Road, Nanyuan Street, Linping District, Hangzhou, Zhejiang, 311100, People’s Republic of China, Tel +86– 18072889033, Email 13376819518@163.comPurpose: Early detection of lung cancer is critical to improving prognosis, yet current screening methods such as low-dose spiral CT and serum CEA each have diagnostic limitations. This study aims to analyze the clinical value of low-dose spiral CT combined with serum CEA in the differential diagnosis of early lung cancer.Materials and Methods: In this retrospective study, 62 patients diagnosed with early lung cancer in our hospital from April 2022 to October 2023 were selected as the case group, and 50 patients diagnosed with benign pulmonary lesions during the same period were selected as the control group. Data from low-dose spiral CT and serum CEA levels were compared. The efficacy of low-dose spiral CT alone, serum CEA alone, and the combination of both in discriminating early lung cancer was assessed using ROC curves.Results: Low-dose spiral CT showed a sensitivity of 77.42%, a specificity of 94.00%, and an AUC of 0.8571 (95% CI: 0.7832– 0.9310) in detecting early lung cancer. Serum CEA levels were significantly higher in the case group compared to the control group (P< 0.05). Serum CEA yielded an AUC of 0.8661 (95% CI: 0.7964– 0.9359) in distinguishing early lung cancer (P< 0.0001). Low-dose spiral CT combined with serum CEA detection achieved an AUC of 0.9137 (95% CI: 0.8624– 0.9650), significantly increasing the early lung cancer detection rate from 82.26% to 95.16% (P< 0.05).Conclusion: Patients with early lung cancer show distinct alterations in low-dose spiral CT signs, and their serum CEA levels demonstrate a notable increase compared with those with benign pulmonary lesions. The combination of low-dose spiral CT with serum CEA can be considered in the discrimination of early lung cancer, which can markedly enhance the positive detection rate while maintaining a minimal rise in false-positive rates.Keywords: low-dose spiral CT, serum carcinoembryonic antigen, early lung cancer, combined detection, discriminative valuehttps://www.dovepress.com/clinical-value-of-low-dose-spiral-ct-combined-with-serum-cea-in-the-di-peer-reviewed-fulltext-article-CMARlow-dose spiral CTserum carcinoembryonic antigenearly lung cancercombined detectiondiscriminative value
spellingShingle Jin J
Wu L
Clinical Value of Low-Dose Spiral CT Combined with Serum CEA in the Differential Diagnosis of Early Lung Cancer
Cancer Management and Research
low-dose spiral CT
serum carcinoembryonic antigen
early lung cancer
combined detection
discriminative value
title Clinical Value of Low-Dose Spiral CT Combined with Serum CEA in the Differential Diagnosis of Early Lung Cancer
title_full Clinical Value of Low-Dose Spiral CT Combined with Serum CEA in the Differential Diagnosis of Early Lung Cancer
title_fullStr Clinical Value of Low-Dose Spiral CT Combined with Serum CEA in the Differential Diagnosis of Early Lung Cancer
title_full_unstemmed Clinical Value of Low-Dose Spiral CT Combined with Serum CEA in the Differential Diagnosis of Early Lung Cancer
title_short Clinical Value of Low-Dose Spiral CT Combined with Serum CEA in the Differential Diagnosis of Early Lung Cancer
title_sort clinical value of low dose spiral ct combined with serum cea in the differential diagnosis of early lung cancer
topic low-dose spiral CT
serum carcinoembryonic antigen
early lung cancer
combined detection
discriminative value
url https://www.dovepress.com/clinical-value-of-low-dose-spiral-ct-combined-with-serum-cea-in-the-di-peer-reviewed-fulltext-article-CMAR
work_keys_str_mv AT jinj clinicalvalueoflowdosespiralctcombinedwithserumceainthedifferentialdiagnosisofearlylungcancer
AT wul clinicalvalueoflowdosespiralctcombinedwithserumceainthedifferentialdiagnosisofearlylungcancer