Technical and Institutional Factors Affecting Specimen Adequacy and Complications in Ultrasound-guided Kidney Biopsy: A Retrospective Cohort Study

Background: Percutaneous ultrasound-guided kidney biopsy is a critical diagnostic tool with a higher rate of complications than most other biopsies. Our prior research identified technical factors that might improve outcomes. Objective: The objective was to measure the impact of these technical and...

Full description

Saved in:
Bibliographic Details
Main Authors: Sydney Murray, Chance Dumaine, Chris Wall, Tamalina Banerjee, James Barton, Michael Moser
Format: Article
Language:English
Published: SAGE Publishing 2025-05-01
Series:Canadian Journal of Kidney Health and Disease
Online Access:https://doi.org/10.1177/20543581251336551
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850206682303430656
author Sydney Murray
Chance Dumaine
Chris Wall
Tamalina Banerjee
James Barton
Michael Moser
author_facet Sydney Murray
Chance Dumaine
Chris Wall
Tamalina Banerjee
James Barton
Michael Moser
author_sort Sydney Murray
collection DOAJ
description Background: Percutaneous ultrasound-guided kidney biopsy is a critical diagnostic tool with a higher rate of complications than most other biopsies. Our prior research identified technical factors that might improve outcomes. Objective: The objective was to measure the impact of these technical and institutional interventions on specimen adequacy and complication rates in kidney biopsies. Design: This is a retrospective cohort study comparing outcomes before and after intervention implementation. Setting: Two hospitals within a single health region in Saskatchewan serving a population of approximately 1 million. Patients: All adult percutaneous ultrasound-guided kidney biopsies performed on adult patients between 2012 to 2016 (n = 242, pre-implementation) and 2017 to 2021 (n = 338, post-implementation). Both native and transplant biopsies were included, while patients under 18, open biopsies, and biopsies of kidney masses were excluded. Measurements: Primary outcomes included specimen adequacy and biopsy complications (hematoma, hemoglobin drop, infection, and arteriovenous fistula formation). Methods: Technical recommendations included introducing the biopsy needle at a 60° angle, targeting a pole, and avoiding the vascular medulla. Institutional recommendations included microscopic screening for all biopsies, limiting the number of radiologists performing procedures, using a checklist, and restricting computed tomography (CT)-guided biopsies to exceptional cases. Multivariate regression analysis assessed biopsy outcomes before and after the recommendations, controlling for known confounders while at the same time refining factors associated with fewer complications and greater diagnostic yield. Results: The rate of non-diagnostic specimens decreased from 10.3% to 4.4% ( P = .005), and complications decreased from 35.5% to 14.2% ( P < .0001). Two or three passes yielded excellent diagnostic success, while 4 passes increased the risk of a complication. Multivariate analysis, after accounting for the collinearity of certain technical factors revealed that medulla avoidance and biopsies done after the implementation of the 2016 recommendations significantly reduced the risk of complications (odds ratio [OR] = 0.37, P < .001) and non-diagnostic biopsies (OR = 0.31, P = .002). Limitations: Retrospective design and novelty bias may be a cause of bias in this study. Because the institutional recommendations were followed for all biopsies, it was not possible to distinguish which recommendation was most associated with the improvements. Because our study was done in a single health region, it is not clear if they are generalizable to other programs. Conclusions: The technical and institutional interventions implemented significantly improved specimen adequacy and reduced complication rates in ultrasound-guided kidney biopsies. We have added to these recommendations in that we have refined the requirement for angling the biopsy needle for ease of use and suggest limiting the number of passes to 2 or 3 whenever possible.
format Article
id doaj-art-ad0bfcf730a14e0e85f9071ed66f3d7a
institution OA Journals
issn 2054-3581
language English
publishDate 2025-05-01
publisher SAGE Publishing
record_format Article
series Canadian Journal of Kidney Health and Disease
spelling doaj-art-ad0bfcf730a14e0e85f9071ed66f3d7a2025-08-20T02:10:42ZengSAGE PublishingCanadian Journal of Kidney Health and Disease2054-35812025-05-011210.1177/20543581251336551Technical and Institutional Factors Affecting Specimen Adequacy and Complications in Ultrasound-guided Kidney Biopsy: A Retrospective Cohort StudySydney Murray0Chance Dumaine1Chris Wall2Tamalina Banerjee3James Barton4Michael Moser5College of Medicine, University of Saskatchewan, Saskatoon, CanadaDepartment of Medicine, University of Saskatchewan, Saskatoon, CanadaDepartment of Radiology, Saskatoon Health Region, SK, CanadaDepartment of Pathology and Laboratory Medicine, Saskatoon Health Region, SK, CanadaDepartment of Medicine, University of Saskatchewan, Saskatoon, CanadaSaskatchewan Renal Transplant Program, Saskatoon, CanadaBackground: Percutaneous ultrasound-guided kidney biopsy is a critical diagnostic tool with a higher rate of complications than most other biopsies. Our prior research identified technical factors that might improve outcomes. Objective: The objective was to measure the impact of these technical and institutional interventions on specimen adequacy and complication rates in kidney biopsies. Design: This is a retrospective cohort study comparing outcomes before and after intervention implementation. Setting: Two hospitals within a single health region in Saskatchewan serving a population of approximately 1 million. Patients: All adult percutaneous ultrasound-guided kidney biopsies performed on adult patients between 2012 to 2016 (n = 242, pre-implementation) and 2017 to 2021 (n = 338, post-implementation). Both native and transplant biopsies were included, while patients under 18, open biopsies, and biopsies of kidney masses were excluded. Measurements: Primary outcomes included specimen adequacy and biopsy complications (hematoma, hemoglobin drop, infection, and arteriovenous fistula formation). Methods: Technical recommendations included introducing the biopsy needle at a 60° angle, targeting a pole, and avoiding the vascular medulla. Institutional recommendations included microscopic screening for all biopsies, limiting the number of radiologists performing procedures, using a checklist, and restricting computed tomography (CT)-guided biopsies to exceptional cases. Multivariate regression analysis assessed biopsy outcomes before and after the recommendations, controlling for known confounders while at the same time refining factors associated with fewer complications and greater diagnostic yield. Results: The rate of non-diagnostic specimens decreased from 10.3% to 4.4% ( P = .005), and complications decreased from 35.5% to 14.2% ( P < .0001). Two or three passes yielded excellent diagnostic success, while 4 passes increased the risk of a complication. Multivariate analysis, after accounting for the collinearity of certain technical factors revealed that medulla avoidance and biopsies done after the implementation of the 2016 recommendations significantly reduced the risk of complications (odds ratio [OR] = 0.37, P < .001) and non-diagnostic biopsies (OR = 0.31, P = .002). Limitations: Retrospective design and novelty bias may be a cause of bias in this study. Because the institutional recommendations were followed for all biopsies, it was not possible to distinguish which recommendation was most associated with the improvements. Because our study was done in a single health region, it is not clear if they are generalizable to other programs. Conclusions: The technical and institutional interventions implemented significantly improved specimen adequacy and reduced complication rates in ultrasound-guided kidney biopsies. We have added to these recommendations in that we have refined the requirement for angling the biopsy needle for ease of use and suggest limiting the number of passes to 2 or 3 whenever possible.https://doi.org/10.1177/20543581251336551
spellingShingle Sydney Murray
Chance Dumaine
Chris Wall
Tamalina Banerjee
James Barton
Michael Moser
Technical and Institutional Factors Affecting Specimen Adequacy and Complications in Ultrasound-guided Kidney Biopsy: A Retrospective Cohort Study
Canadian Journal of Kidney Health and Disease
title Technical and Institutional Factors Affecting Specimen Adequacy and Complications in Ultrasound-guided Kidney Biopsy: A Retrospective Cohort Study
title_full Technical and Institutional Factors Affecting Specimen Adequacy and Complications in Ultrasound-guided Kidney Biopsy: A Retrospective Cohort Study
title_fullStr Technical and Institutional Factors Affecting Specimen Adequacy and Complications in Ultrasound-guided Kidney Biopsy: A Retrospective Cohort Study
title_full_unstemmed Technical and Institutional Factors Affecting Specimen Adequacy and Complications in Ultrasound-guided Kidney Biopsy: A Retrospective Cohort Study
title_short Technical and Institutional Factors Affecting Specimen Adequacy and Complications in Ultrasound-guided Kidney Biopsy: A Retrospective Cohort Study
title_sort technical and institutional factors affecting specimen adequacy and complications in ultrasound guided kidney biopsy a retrospective cohort study
url https://doi.org/10.1177/20543581251336551
work_keys_str_mv AT sydneymurray technicalandinstitutionalfactorsaffectingspecimenadequacyandcomplicationsinultrasoundguidedkidneybiopsyaretrospectivecohortstudy
AT chancedumaine technicalandinstitutionalfactorsaffectingspecimenadequacyandcomplicationsinultrasoundguidedkidneybiopsyaretrospectivecohortstudy
AT chriswall technicalandinstitutionalfactorsaffectingspecimenadequacyandcomplicationsinultrasoundguidedkidneybiopsyaretrospectivecohortstudy
AT tamalinabanerjee technicalandinstitutionalfactorsaffectingspecimenadequacyandcomplicationsinultrasoundguidedkidneybiopsyaretrospectivecohortstudy
AT jamesbarton technicalandinstitutionalfactorsaffectingspecimenadequacyandcomplicationsinultrasoundguidedkidneybiopsyaretrospectivecohortstudy
AT michaelmoser technicalandinstitutionalfactorsaffectingspecimenadequacyandcomplicationsinultrasoundguidedkidneybiopsyaretrospectivecohortstudy