IMPACT OF SEASONALITY OF GENERATION AND LOAD ON THE OPTIMAL CAPACITY OF THE ENERGY STORAGE SYSTEM OF THE PROSUMER’S MICROGRID
Due to the instability of renewable energy sources, maintaining the stable operation of microgrids becomes an urgent and difficult task. energy storage systems can provide uninterrupted power for such Microgrids, but their integration is accompanied by challenges related to determining the optimal s...
Saved in:
| Main Authors: | , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
NAS of Ukraine, Institute of elecrodynamics
2025-04-01
|
| Series: | Технічна електродинаміка |
| Subjects: | |
| Online Access: | https://techned.org.ua/index.php/techned/article/view/1672 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850284314248347648 |
|---|---|
| author | O.В. Кулапін A.В. Івахнов С.O. Федорчук К.В. Махотіло Д.О. Данильченко О.В. Булгаков |
| author_facet | O.В. Кулапін A.В. Івахнов С.O. Федорчук К.В. Махотіло Д.О. Данильченко О.В. Булгаков |
| author_sort | O.В. Кулапін |
| collection | DOAJ |
| description | Due to the instability of renewable energy sources, maintaining the stable operation of microgrids becomes an urgent and difficult task. energy storage systems can provide uninterrupted power for such Microgrids, but their integration is accompanied by challenges related to determining the optimal storage parameters. This study presents a method that allows optimizing the capacity of the energy storage system, taking into account various controller algorithms of the operation of the prosumer’s microgrid. Purpose. Development of a method for determining the optimal capacity of an energy storage system to maximize profit from interaction prosumer’s microgrid with the power grid. Two radically different controller algorithms of microgrid operation are considered: the first is focused on the maximum use of solar generation, and the second is on the balanced use of all elements of the prosumer’s microgrid system, including storage and energy consumption. A microgrid was studied using the example of a prosumer, which includes a solar photovoltaic system, a load profile, an energy storage system and connection to the power grid at a three-zone time-to-use tariff. In order to evaluate the effectiveness of the selected strategies, an analysis of indicators for winter and summer days was carried out, which made it possible to reveal the effect of seasonality on the operation of the microgrid. The proposed method allows to determine the capacity of the energy storage system when designing individual solar photovoltaic system. References 15, table 2, figures 10. |
| format | Article |
| id | doaj-art-acfcf33d8d5449cf8863dc670e599355 |
| institution | OA Journals |
| issn | 1607-7970 2218-1903 |
| language | English |
| publishDate | 2025-04-01 |
| publisher | NAS of Ukraine, Institute of elecrodynamics |
| record_format | Article |
| series | Технічна електродинаміка |
| spelling | doaj-art-acfcf33d8d5449cf8863dc670e5993552025-08-20T01:47:36ZengNAS of Ukraine, Institute of elecrodynamicsТехнічна електродинаміка1607-79702218-19032025-04-01307307310.15407/techned2025.03.0731672IMPACT OF SEASONALITY OF GENERATION AND LOAD ON THE OPTIMAL CAPACITY OF THE ENERGY STORAGE SYSTEM OF THE PROSUMER’S MICROGRIDO.В. Кулапін0https://orcid.org/0000-0001-9283-6910A.В. Івахнов1https://orcid.org/0000-0001-8280-0033С.O. Федорчук2https://orcid.org/0000-0001-7676-8313К.В. Махотіло3https://orcid.org/0000-0001-7081-071XД.О. Данильченко4https://orcid.org/0000-0001-7912-1849О.В. Булгаков5https://orcid.org/0000-0002-3244-420XNational Technical University «Kharkiv Polytechnic Institute», Kirpichova str., 2, Kharkiv, 61002, UkraineNational Technical University «Kharkiv Polytechnic Institute», 2, Kyrpychova Str., Kharkiv, 61002, UkraineNational Technical University «Kharkiv Polytechnic Institute», Kirpichova str., 2, Kharkiv, 61002, UkraineNational Technical University «Kharkiv Polytechnic Institute», Kirpichova str., 2, Kharkiv, 61002, UkraineNational Technical University «Kharkiv Polytechnic Institute», Kirpichova str., 2, Kharkiv, 61002, UkraineNational Technical University «Kharkiv Polytechnic Institute», Kirpichova str., 2, Kharkiv, 61002, UkraineDue to the instability of renewable energy sources, maintaining the stable operation of microgrids becomes an urgent and difficult task. energy storage systems can provide uninterrupted power for such Microgrids, but their integration is accompanied by challenges related to determining the optimal storage parameters. This study presents a method that allows optimizing the capacity of the energy storage system, taking into account various controller algorithms of the operation of the prosumer’s microgrid. Purpose. Development of a method for determining the optimal capacity of an energy storage system to maximize profit from interaction prosumer’s microgrid with the power grid. Two radically different controller algorithms of microgrid operation are considered: the first is focused on the maximum use of solar generation, and the second is on the balanced use of all elements of the prosumer’s microgrid system, including storage and energy consumption. A microgrid was studied using the example of a prosumer, which includes a solar photovoltaic system, a load profile, an energy storage system and connection to the power grid at a three-zone time-to-use tariff. In order to evaluate the effectiveness of the selected strategies, an analysis of indicators for winter and summer days was carried out, which made it possible to reveal the effect of seasonality on the operation of the microgrid. The proposed method allows to determine the capacity of the energy storage system when designing individual solar photovoltaic system. References 15, table 2, figures 10.https://techned.org.ua/index.php/techned/article/view/1672microgridload modellingprosumerenergy storagerenewable energy sourcesoptimization |
| spellingShingle | O.В. Кулапін A.В. Івахнов С.O. Федорчук К.В. Махотіло Д.О. Данильченко О.В. Булгаков IMPACT OF SEASONALITY OF GENERATION AND LOAD ON THE OPTIMAL CAPACITY OF THE ENERGY STORAGE SYSTEM OF THE PROSUMER’S MICROGRID Технічна електродинаміка microgrid load modelling prosumer energy storage renewable energy sources optimization |
| title | IMPACT OF SEASONALITY OF GENERATION AND LOAD ON THE OPTIMAL CAPACITY OF THE ENERGY STORAGE SYSTEM OF THE PROSUMER’S MICROGRID |
| title_full | IMPACT OF SEASONALITY OF GENERATION AND LOAD ON THE OPTIMAL CAPACITY OF THE ENERGY STORAGE SYSTEM OF THE PROSUMER’S MICROGRID |
| title_fullStr | IMPACT OF SEASONALITY OF GENERATION AND LOAD ON THE OPTIMAL CAPACITY OF THE ENERGY STORAGE SYSTEM OF THE PROSUMER’S MICROGRID |
| title_full_unstemmed | IMPACT OF SEASONALITY OF GENERATION AND LOAD ON THE OPTIMAL CAPACITY OF THE ENERGY STORAGE SYSTEM OF THE PROSUMER’S MICROGRID |
| title_short | IMPACT OF SEASONALITY OF GENERATION AND LOAD ON THE OPTIMAL CAPACITY OF THE ENERGY STORAGE SYSTEM OF THE PROSUMER’S MICROGRID |
| title_sort | impact of seasonality of generation and load on the optimal capacity of the energy storage system of the prosumer s microgrid |
| topic | microgrid load modelling prosumer energy storage renewable energy sources optimization |
| url | https://techned.org.ua/index.php/techned/article/view/1672 |
| work_keys_str_mv | AT ovkulapín impactofseasonalityofgenerationandloadontheoptimalcapacityoftheenergystoragesystemoftheprosumersmicrogrid AT avívahnov impactofseasonalityofgenerationandloadontheoptimalcapacityoftheenergystoragesystemoftheprosumersmicrogrid AT sofedorčuk impactofseasonalityofgenerationandloadontheoptimalcapacityoftheenergystoragesystemoftheprosumersmicrogrid AT kvmahotílo impactofseasonalityofgenerationandloadontheoptimalcapacityoftheenergystoragesystemoftheprosumersmicrogrid AT dodanilʹčenko impactofseasonalityofgenerationandloadontheoptimalcapacityoftheenergystoragesystemoftheprosumersmicrogrid AT ovbulgakov impactofseasonalityofgenerationandloadontheoptimalcapacityoftheenergystoragesystemoftheprosumersmicrogrid |