Data Processing Procedure for Real-Time Odour Concentration Estimation at Industrial Plant Fenceline by Sensor-Based Tools

The realisation of an electronic nose network for the monitoring of the odour concentrations at the fenceline of a waste treatment plant has been investigated. One of the main challenges for instrumental environmental monitoring concerns the interference of the daily variability of humidity and temp...

Full description

Saved in:
Bibliographic Details
Main Authors: Christian Ratti, Beatrice Julia Lotesoriere, Carmen Bax, Laura Capelli
Format: Article
Language:English
Published: MDPI AG 2024-03-01
Series:Proceedings
Subjects:
Online Access:https://www.mdpi.com/2504-3900/97/1/4
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850238770200182784
author Christian Ratti
Beatrice Julia Lotesoriere
Carmen Bax
Laura Capelli
author_facet Christian Ratti
Beatrice Julia Lotesoriere
Carmen Bax
Laura Capelli
author_sort Christian Ratti
collection DOAJ
description The realisation of an electronic nose network for the monitoring of the odour concentrations at the fenceline of a waste treatment plant has been investigated. One of the main challenges for instrumental environmental monitoring concerns the interference of the daily variability of humidity and temperature of the ambient air to which sensors are exposed. In this study, we propose a solution to overcome this problem, implementing a specific normalisation pretreatment into the data processing procedure. The preliminary results obtained show a better classification and quantification performance whenever humidity model compensation is applied.
format Article
id doaj-art-abddeb5ef4c340caa93e3bf9b0be711d
institution OA Journals
issn 2504-3900
language English
publishDate 2024-03-01
publisher MDPI AG
record_format Article
series Proceedings
spelling doaj-art-abddeb5ef4c340caa93e3bf9b0be711d2025-08-20T02:01:21ZengMDPI AGProceedings2504-39002024-03-01971410.3390/proceedings2024097004Data Processing Procedure for Real-Time Odour Concentration Estimation at Industrial Plant Fenceline by Sensor-Based ToolsChristian Ratti0Beatrice Julia Lotesoriere1Carmen Bax2Laura Capelli3Department of Chemistry, Materials and Chemical Engineering, “Giulio Natta”, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 20133 Milan, ItalyDepartment of Chemistry, Materials and Chemical Engineering, “Giulio Natta”, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 20133 Milan, ItalyDepartment of Chemistry, Materials and Chemical Engineering, “Giulio Natta”, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 20133 Milan, ItalyDepartment of Chemistry, Materials and Chemical Engineering, “Giulio Natta”, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 20133 Milan, ItalyThe realisation of an electronic nose network for the monitoring of the odour concentrations at the fenceline of a waste treatment plant has been investigated. One of the main challenges for instrumental environmental monitoring concerns the interference of the daily variability of humidity and temperature of the ambient air to which sensors are exposed. In this study, we propose a solution to overcome this problem, implementing a specific normalisation pretreatment into the data processing procedure. The preliminary results obtained show a better classification and quantification performance whenever humidity model compensation is applied.https://www.mdpi.com/2504-3900/97/1/4real-time environmental monitoringsignal pretreatmentmachine learning
spellingShingle Christian Ratti
Beatrice Julia Lotesoriere
Carmen Bax
Laura Capelli
Data Processing Procedure for Real-Time Odour Concentration Estimation at Industrial Plant Fenceline by Sensor-Based Tools
Proceedings
real-time environmental monitoring
signal pretreatment
machine learning
title Data Processing Procedure for Real-Time Odour Concentration Estimation at Industrial Plant Fenceline by Sensor-Based Tools
title_full Data Processing Procedure for Real-Time Odour Concentration Estimation at Industrial Plant Fenceline by Sensor-Based Tools
title_fullStr Data Processing Procedure for Real-Time Odour Concentration Estimation at Industrial Plant Fenceline by Sensor-Based Tools
title_full_unstemmed Data Processing Procedure for Real-Time Odour Concentration Estimation at Industrial Plant Fenceline by Sensor-Based Tools
title_short Data Processing Procedure for Real-Time Odour Concentration Estimation at Industrial Plant Fenceline by Sensor-Based Tools
title_sort data processing procedure for real time odour concentration estimation at industrial plant fenceline by sensor based tools
topic real-time environmental monitoring
signal pretreatment
machine learning
url https://www.mdpi.com/2504-3900/97/1/4
work_keys_str_mv AT christianratti dataprocessingprocedureforrealtimeodourconcentrationestimationatindustrialplantfencelinebysensorbasedtools
AT beatricejulialotesoriere dataprocessingprocedureforrealtimeodourconcentrationestimationatindustrialplantfencelinebysensorbasedtools
AT carmenbax dataprocessingprocedureforrealtimeodourconcentrationestimationatindustrialplantfencelinebysensorbasedtools
AT lauracapelli dataprocessingprocedureforrealtimeodourconcentrationestimationatindustrialplantfencelinebysensorbasedtools