In vitro analysis of the marginal adaptation and discrepancy of stainless steel crowns
Aim: The purpose of the study was to assess the marginal adaptation and discrepancy of SSC’s. Differences in adaptation and discrepancy between the four surfaces (mesial, lingual, distal, and buccal) were evaluated. Methods: The placement of stainless steel crowns were completed on a phantom head in...
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Medical Journals Sweden
2018-01-01
|
| Series: | Acta Biomaterialia Odontologica Scandinavica |
| Subjects: | |
| Online Access: | http://dx.doi.org/10.1080/23337931.2018.1444995 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850283411463208960 |
|---|---|
| author | Riaan Mulder Rasha Medhat Nadia Mohamed |
| author_facet | Riaan Mulder Rasha Medhat Nadia Mohamed |
| author_sort | Riaan Mulder |
| collection | DOAJ |
| description | Aim: The purpose of the study was to assess the marginal adaptation and discrepancy of SSC’s. Differences in adaptation and discrepancy between the four surfaces (mesial, lingual, distal, and buccal) were evaluated. Methods: The placement of stainless steel crowns were completed on a phantom head in accordance with the clinical technique. The ideal tooth preparation was made and this ‘master tooth’ duplicated to achieve a sample size of 15. The stainless steel crowns were placed, trimmed, and cemented as per the clinical technique. The cemented stainless crowns were analyzed under 100× stereomicroscope magnification. The marginal adaptation and discrepancy of each specimen was measured every 2 µm. Results: All the specimens showed marginal adaptation and discrepancy. The lingual margin had a significantly better adaptation (p < .0001) over the other surfaces. The buccal surface was the only surface that had an appropriate supra-CEJ level with a significance of p < .0001. Conclusion: The marginal discrepancies occur during the trimming procedure and assessment of the gingival approximation of the SSC margin. The inspection of stainless steel crown adaptation and discrepancy is an essential clinical step. |
| format | Article |
| id | doaj-art-a8fa03b3a21247868c698554e2f6e69c |
| institution | OA Journals |
| issn | 2333-7931 |
| language | English |
| publishDate | 2018-01-01 |
| publisher | Medical Journals Sweden |
| record_format | Article |
| series | Acta Biomaterialia Odontologica Scandinavica |
| spelling | doaj-art-a8fa03b3a21247868c698554e2f6e69c2025-08-20T01:47:47ZengMedical Journals SwedenActa Biomaterialia Odontologica Scandinavica2333-79312018-01-0141202910.1080/23337931.2018.14449951444995In vitro analysis of the marginal adaptation and discrepancy of stainless steel crownsRiaan Mulder0Rasha Medhat1Nadia Mohamed2University of the Western CapeUniversity of the Western CapeUniversity of the Western CapeAim: The purpose of the study was to assess the marginal adaptation and discrepancy of SSC’s. Differences in adaptation and discrepancy between the four surfaces (mesial, lingual, distal, and buccal) were evaluated. Methods: The placement of stainless steel crowns were completed on a phantom head in accordance with the clinical technique. The ideal tooth preparation was made and this ‘master tooth’ duplicated to achieve a sample size of 15. The stainless steel crowns were placed, trimmed, and cemented as per the clinical technique. The cemented stainless crowns were analyzed under 100× stereomicroscope magnification. The marginal adaptation and discrepancy of each specimen was measured every 2 µm. Results: All the specimens showed marginal adaptation and discrepancy. The lingual margin had a significantly better adaptation (p < .0001) over the other surfaces. The buccal surface was the only surface that had an appropriate supra-CEJ level with a significance of p < .0001. Conclusion: The marginal discrepancies occur during the trimming procedure and assessment of the gingival approximation of the SSC margin. The inspection of stainless steel crown adaptation and discrepancy is an essential clinical step.http://dx.doi.org/10.1080/23337931.2018.1444995Biomaterial cementstainless steel crowngingival approximationcrown margin |
| spellingShingle | Riaan Mulder Rasha Medhat Nadia Mohamed In vitro analysis of the marginal adaptation and discrepancy of stainless steel crowns Acta Biomaterialia Odontologica Scandinavica Biomaterial cement stainless steel crown gingival approximation crown margin |
| title | In vitro analysis of the marginal adaptation and discrepancy of stainless steel crowns |
| title_full | In vitro analysis of the marginal adaptation and discrepancy of stainless steel crowns |
| title_fullStr | In vitro analysis of the marginal adaptation and discrepancy of stainless steel crowns |
| title_full_unstemmed | In vitro analysis of the marginal adaptation and discrepancy of stainless steel crowns |
| title_short | In vitro analysis of the marginal adaptation and discrepancy of stainless steel crowns |
| title_sort | in vitro analysis of the marginal adaptation and discrepancy of stainless steel crowns |
| topic | Biomaterial cement stainless steel crown gingival approximation crown margin |
| url | http://dx.doi.org/10.1080/23337931.2018.1444995 |
| work_keys_str_mv | AT riaanmulder invitroanalysisofthemarginaladaptationanddiscrepancyofstainlesssteelcrowns AT rashamedhat invitroanalysisofthemarginaladaptationanddiscrepancyofstainlesssteelcrowns AT nadiamohamed invitroanalysisofthemarginaladaptationanddiscrepancyofstainlesssteelcrowns |