Application of the wavelet transform in problems of searching for a damaged connection with a single-phase earth fault according to SV-stream data

Introduction. Research relevance is conditioned by the necessity to increase selectivity of protection and signaling devices for single-phase ground faults in 6-10 kV networks. Single-phase ground faults are one of the prevailing causes of equipment failures in the oil and gas production sector of R...

Full description

Saved in:
Bibliographic Details
Main Authors: A. O. Paramzin, S. Yu. Dolinger
Format: Article
Language:Russian
Published: North Caucasus Federal University 2024-10-01
Series:Вестник Северо-Кавказского федерального университета
Subjects:
Online Access:https://vestnikskfu.elpub.ru/jour/article/view/2740
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850047857802870784
author A. O. Paramzin
S. Yu. Dolinger
author_facet A. O. Paramzin
S. Yu. Dolinger
author_sort A. O. Paramzin
collection DOAJ
description Introduction. Research relevance is conditioned by the necessity to increase selectivity of protection and signaling devices for single-phase ground faults in 6-10 kV networks. Single-phase ground faults are one of the prevailing causes of equipment failures in the oil and gas production sector of Russia, which is the backbone of the economy.Goal. The article aims is verification of the possibility of using the Sample Value data of IEC 61850 in the tasks of finding a faulty feeder with single-phase earth fault by means of wavelet transform.Materials and methods. Wavelet transform with decomposition to the 6th level of zero-sequence current 3i0. Interpolation of SV-flow data. Determination of effective values of higher harmonic currents by wavelet coefficients.Results and discussion. The magnitude of the relative deviation of the calculated effective values of the higher harmonic currents between the data of the current sensor with a sampling frequency of 12,800 Hz and the interpolated values of the SV flow with an increased frequency from 4,000 to 12,800 Hz was 1.18 % with damage to the connection feeding the nonlinear load and 2.86 % in the experiment with a sinusoidal load.Conclusion. Experimental results show that the highest value of the sum of the higher harmonic currents corresponds to the feeder with the presence of a single-phase ground fault. The limited number of samples per period poses the challenge of interpolating the Sampled Value data up to a frequency of 12 800 Hz.
format Article
id doaj-art-a7e63bf82ce448a4a4fd8bcc7338d1ea
institution DOAJ
issn 2307-907X
language Russian
publishDate 2024-10-01
publisher North Caucasus Federal University
record_format Article
series Вестник Северо-Кавказского федерального университета
spelling doaj-art-a7e63bf82ce448a4a4fd8bcc7338d1ea2025-08-20T02:54:06ZrusNorth Caucasus Federal UniversityВестник Северо-Кавказского федерального университета2307-907X2024-10-0104172710.37493/2307-907X.2024.4.22648Application of the wavelet transform in problems of searching for a damaged connection with a single-phase earth fault according to SV-stream dataA. O. Paramzin0S. Yu. Dolinger1Yugra State UniversityYugra State UniversityIntroduction. Research relevance is conditioned by the necessity to increase selectivity of protection and signaling devices for single-phase ground faults in 6-10 kV networks. Single-phase ground faults are one of the prevailing causes of equipment failures in the oil and gas production sector of Russia, which is the backbone of the economy.Goal. The article aims is verification of the possibility of using the Sample Value data of IEC 61850 in the tasks of finding a faulty feeder with single-phase earth fault by means of wavelet transform.Materials and methods. Wavelet transform with decomposition to the 6th level of zero-sequence current 3i0. Interpolation of SV-flow data. Determination of effective values of higher harmonic currents by wavelet coefficients.Results and discussion. The magnitude of the relative deviation of the calculated effective values of the higher harmonic currents between the data of the current sensor with a sampling frequency of 12,800 Hz and the interpolated values of the SV flow with an increased frequency from 4,000 to 12,800 Hz was 1.18 % with damage to the connection feeding the nonlinear load and 2.86 % in the experiment with a sinusoidal load.Conclusion. Experimental results show that the highest value of the sum of the higher harmonic currents corresponds to the feeder with the presence of a single-phase ground fault. The limited number of samples per period poses the challenge of interpolating the Sampled Value data up to a frequency of 12 800 Hz.https://vestnikskfu.elpub.ru/jour/article/view/2740single-phase ground faultisolated neutralhigher harmonicsiec 61850wavelet transform
spellingShingle A. O. Paramzin
S. Yu. Dolinger
Application of the wavelet transform in problems of searching for a damaged connection with a single-phase earth fault according to SV-stream data
Вестник Северо-Кавказского федерального университета
single-phase ground fault
isolated neutral
higher harmonics
iec 61850
wavelet transform
title Application of the wavelet transform in problems of searching for a damaged connection with a single-phase earth fault according to SV-stream data
title_full Application of the wavelet transform in problems of searching for a damaged connection with a single-phase earth fault according to SV-stream data
title_fullStr Application of the wavelet transform in problems of searching for a damaged connection with a single-phase earth fault according to SV-stream data
title_full_unstemmed Application of the wavelet transform in problems of searching for a damaged connection with a single-phase earth fault according to SV-stream data
title_short Application of the wavelet transform in problems of searching for a damaged connection with a single-phase earth fault according to SV-stream data
title_sort application of the wavelet transform in problems of searching for a damaged connection with a single phase earth fault according to sv stream data
topic single-phase ground fault
isolated neutral
higher harmonics
iec 61850
wavelet transform
url https://vestnikskfu.elpub.ru/jour/article/view/2740
work_keys_str_mv AT aoparamzin applicationofthewavelettransforminproblemsofsearchingforadamagedconnectionwithasinglephaseearthfaultaccordingtosvstreamdata
AT syudolinger applicationofthewavelettransforminproblemsofsearchingforadamagedconnectionwithasinglephaseearthfaultaccordingtosvstreamdata