Realization of the DFIG in Condition of the Uninterrupted Operation while Serious Asymmetry or ZVS of Grid Voltage Occurred

A kind of control plan adaptive to serious asymmetry or ZVS of grid voltage is put forward, which can realize uninterrupted operation of the DFIG. It can be fit for small value symmetric drop and unbalanced three-phase control of the grid. The time sequence of whole uninterrupted operation is analyz...

Full description

Saved in:
Bibliographic Details
Main Authors: XU Fengxing, SHE Yue, LIU Liangen, JIANG Yaosheng, LIU Zhixing, LIU Pengfei
Format: Article
Language:zho
Published: Editorial Office of Control and Information Technology 2012-01-01
Series:Kongzhi Yu Xinxi Jishu
Subjects:
Online Access:http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2012.01.011
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849224669017669632
author XU Fengxing
SHE Yue
LIU Liangen
JIANG Yaosheng
LIU Zhixing
LIU Pengfei
author_facet XU Fengxing
SHE Yue
LIU Liangen
JIANG Yaosheng
LIU Zhixing
LIU Pengfei
author_sort XU Fengxing
collection DOAJ
description A kind of control plan adaptive to serious asymmetry or ZVS of grid voltage is put forward, which can realize uninterrupted operation of the DFIG. It can be fit for small value symmetric drop and unbalanced three-phase control of the grid. The time sequence of whole uninterrupted operation is analyzed in detail, and based on the simulation research with PSIM, the experimental research is implemented for whole uninterrupted operation process through the Back-Back Test Bench and the prototype. The simulation and experiment results show that correctness and effectiveness of the control strategy are fully meet the connected-grid requirements of the power grid companies.
format Article
id doaj-art-a7ccdcb53bc047639c8ce87a0031c7f0
institution Kabale University
issn 2096-5427
language zho
publishDate 2012-01-01
publisher Editorial Office of Control and Information Technology
record_format Article
series Kongzhi Yu Xinxi Jishu
spelling doaj-art-a7ccdcb53bc047639c8ce87a0031c7f02025-08-25T06:56:28ZzhoEditorial Office of Control and Information TechnologyKongzhi Yu Xinxi Jishu2096-54272012-01-0129394382338152Realization of the DFIG in Condition of the Uninterrupted Operation while Serious Asymmetry or ZVS of Grid Voltage OccurredXU FengxingSHE YueLIU LiangenJIANG YaoshengLIU ZhixingLIU PengfeiA kind of control plan adaptive to serious asymmetry or ZVS of grid voltage is put forward, which can realize uninterrupted operation of the DFIG. It can be fit for small value symmetric drop and unbalanced three-phase control of the grid. The time sequence of whole uninterrupted operation is analyzed in detail, and based on the simulation research with PSIM, the experimental research is implemented for whole uninterrupted operation process through the Back-Back Test Bench and the prototype. The simulation and experiment results show that correctness and effectiveness of the control strategy are fully meet the connected-grid requirements of the power grid companies.http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2012.01.011double-fed induction generatorgrid faultspace vecter pluse width modulation (SVPWM)uninterrupted operation
spellingShingle XU Fengxing
SHE Yue
LIU Liangen
JIANG Yaosheng
LIU Zhixing
LIU Pengfei
Realization of the DFIG in Condition of the Uninterrupted Operation while Serious Asymmetry or ZVS of Grid Voltage Occurred
Kongzhi Yu Xinxi Jishu
double-fed induction generator
grid fault
space vecter pluse width modulation (SVPWM)
uninterrupted operation
title Realization of the DFIG in Condition of the Uninterrupted Operation while Serious Asymmetry or ZVS of Grid Voltage Occurred
title_full Realization of the DFIG in Condition of the Uninterrupted Operation while Serious Asymmetry or ZVS of Grid Voltage Occurred
title_fullStr Realization of the DFIG in Condition of the Uninterrupted Operation while Serious Asymmetry or ZVS of Grid Voltage Occurred
title_full_unstemmed Realization of the DFIG in Condition of the Uninterrupted Operation while Serious Asymmetry or ZVS of Grid Voltage Occurred
title_short Realization of the DFIG in Condition of the Uninterrupted Operation while Serious Asymmetry or ZVS of Grid Voltage Occurred
title_sort realization of the dfig in condition of the uninterrupted operation while serious asymmetry or zvs of grid voltage occurred
topic double-fed induction generator
grid fault
space vecter pluse width modulation (SVPWM)
uninterrupted operation
url http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2012.01.011
work_keys_str_mv AT xufengxing realizationofthedfiginconditionoftheuninterruptedoperationwhileseriousasymmetryorzvsofgridvoltageoccurred
AT sheyue realizationofthedfiginconditionoftheuninterruptedoperationwhileseriousasymmetryorzvsofgridvoltageoccurred
AT liuliangen realizationofthedfiginconditionoftheuninterruptedoperationwhileseriousasymmetryorzvsofgridvoltageoccurred
AT jiangyaosheng realizationofthedfiginconditionoftheuninterruptedoperationwhileseriousasymmetryorzvsofgridvoltageoccurred
AT liuzhixing realizationofthedfiginconditionoftheuninterruptedoperationwhileseriousasymmetryorzvsofgridvoltageoccurred
AT liupengfei realizationofthedfiginconditionoftheuninterruptedoperationwhileseriousasymmetryorzvsofgridvoltageoccurred