Robotic Assistance is Associated With No Intraoperative Fluoroscopy or Radiation Exposure During Direct Anterior Total Hip Arthroplasty

Background: As more total hip arthroplasty (THA) procedures continue to be performed and concomitant intraoperative fluoroscopic utilization continues to increase, it is important for surgeons to critically analyze this practice during their procedures. The direct anterior approach (DAA) is a popula...

Full description

Saved in:
Bibliographic Details
Main Authors: Sean Sequeira, MD, Alan Brett, PhD, Joseph Nessler, MD, Benjamin Frye, MD, Michael A. Mont, MD
Format: Article
Language:English
Published: Elsevier 2025-04-01
Series:Arthroplasty Today
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2352344125000044
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1825199440989782016
author Sean Sequeira, MD
Alan Brett, PhD
Joseph Nessler, MD
Benjamin Frye, MD
Michael A. Mont, MD
author_facet Sean Sequeira, MD
Alan Brett, PhD
Joseph Nessler, MD
Benjamin Frye, MD
Michael A. Mont, MD
author_sort Sean Sequeira, MD
collection DOAJ
description Background: As more total hip arthroplasty (THA) procedures continue to be performed and concomitant intraoperative fluoroscopic utilization continues to increase, it is important for surgeons to critically analyze this practice during their procedures. The direct anterior approach (DAA) is a popular technique, but often requires the use of fluoroscopy for evaluation of component positioning and implantation. Computed tomography (CT)–based robotic-assisted THA (RA-THA) may represent an alternative to conventional procedures, which may allow the avoidance of the use of intraoperative fluoroscopy to be avoided and instead rely on a preoperative CT scan of the patient and intraoperative mapping. The purpose of this study was to evaluate the difference in radiation exposure from CT-based RA-THA DAA vs fluoroscopy-guided conventional THA DAA based on values from a cadaver study. Methods: There were 2 surgeons who had previous extensive experience with the DAA, as well as conventional and RA-THA. They completed bilateral direct anterior THAs on 6 cadaver specimens. For each cadaver, a conventional THA with fluoroscopy was performed on the first hip, and a robotically assisted THA without fluoroscopy was performed on the contralateral hip. For all robotic-assisted cases, a preoperative 3-dimensional CT was performed. The radiation dosage from the preoperative scan was acquired through the radiation dose structured reports. Radiation exposure dosage for intraoperative fluoroscopy required tabulation of the number of fluoroscopy shots performed for each case as well as the length of time of exposure. This time was then converted to an effective radiation dose based on accepted standards, and this was multiplied by the average number of fluoroscopy shots per case to determine the average dosage per case. Results: No fluoroscopic images were taken during the RA-THA using the DAA. There was a mean of 21 ± 8.9 fluoroscopic shots taken during each fluoroscopy-guided conventional THA using the DAA. The minimum number of fluoroscopic shots was 9, with a maximum of 31. Total radiation exposure ranged from 300 to 1033 mrem, with an average of 700 mrem. The average radiation exposure for a hip CT scan was 289 mrem. Conclusions: In this cadaver-based study, the use of a CT-based RA-THA DAA eliminated the need for intraoperative fluoroscopy, removing the concern of radiation exposure to the surgeon and surgical staff. The CT-based RA-THA DAA does require a preoperative CT scan of the patient; however, the radiation dosage to the patient was equivalent to 8.7 intraoperative fluoroscopy shots. As more surgeons, patients, and surgical staff are exposed to an increasing number of orthopaedic procedures that require ionizing radiation to generate images, such as fluoroscopy and CT, it is important to consider the radiation dosage for all individuals and understand the positives and negatives of each treatment. We must consider the overall long-term health impacts of continuous fluoroscopy vs a one-time CT scan. This is of particular importance to the surgeon and surgical staff who may be exposed to cumulative doses during multiple procedures.
format Article
id doaj-art-a7b275ea7ee6410d9b6cdacc0984b9f8
institution Kabale University
issn 2352-3441
language English
publishDate 2025-04-01
publisher Elsevier
record_format Article
series Arthroplasty Today
spelling doaj-art-a7b275ea7ee6410d9b6cdacc0984b9f82025-02-08T05:00:36ZengElsevierArthroplasty Today2352-34412025-04-0132101617Robotic Assistance is Associated With No Intraoperative Fluoroscopy or Radiation Exposure During Direct Anterior Total Hip ArthroplastySean Sequeira, MD0Alan Brett, PhD1Joseph Nessler, MD2Benjamin Frye, MD3Michael A. Mont, MD4Medstar Union Memorial Hospital, Baltimore, MD, USAStryker Orthopaedics, Mahwah, NJ, USASt. Cloud Orthopedics, Sartell, MN, USAWest Virginia University, Morgantown, WV, USAThe Rubin Institute for Advance Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD, USA; Corresponding author. The Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, 2401 West Belvedere Avenue, Baltimore, MD 21215, USA. Tel.: +1 410 554 2000.Background: As more total hip arthroplasty (THA) procedures continue to be performed and concomitant intraoperative fluoroscopic utilization continues to increase, it is important for surgeons to critically analyze this practice during their procedures. The direct anterior approach (DAA) is a popular technique, but often requires the use of fluoroscopy for evaluation of component positioning and implantation. Computed tomography (CT)–based robotic-assisted THA (RA-THA) may represent an alternative to conventional procedures, which may allow the avoidance of the use of intraoperative fluoroscopy to be avoided and instead rely on a preoperative CT scan of the patient and intraoperative mapping. The purpose of this study was to evaluate the difference in radiation exposure from CT-based RA-THA DAA vs fluoroscopy-guided conventional THA DAA based on values from a cadaver study. Methods: There were 2 surgeons who had previous extensive experience with the DAA, as well as conventional and RA-THA. They completed bilateral direct anterior THAs on 6 cadaver specimens. For each cadaver, a conventional THA with fluoroscopy was performed on the first hip, and a robotically assisted THA without fluoroscopy was performed on the contralateral hip. For all robotic-assisted cases, a preoperative 3-dimensional CT was performed. The radiation dosage from the preoperative scan was acquired through the radiation dose structured reports. Radiation exposure dosage for intraoperative fluoroscopy required tabulation of the number of fluoroscopy shots performed for each case as well as the length of time of exposure. This time was then converted to an effective radiation dose based on accepted standards, and this was multiplied by the average number of fluoroscopy shots per case to determine the average dosage per case. Results: No fluoroscopic images were taken during the RA-THA using the DAA. There was a mean of 21 ± 8.9 fluoroscopic shots taken during each fluoroscopy-guided conventional THA using the DAA. The minimum number of fluoroscopic shots was 9, with a maximum of 31. Total radiation exposure ranged from 300 to 1033 mrem, with an average of 700 mrem. The average radiation exposure for a hip CT scan was 289 mrem. Conclusions: In this cadaver-based study, the use of a CT-based RA-THA DAA eliminated the need for intraoperative fluoroscopy, removing the concern of radiation exposure to the surgeon and surgical staff. The CT-based RA-THA DAA does require a preoperative CT scan of the patient; however, the radiation dosage to the patient was equivalent to 8.7 intraoperative fluoroscopy shots. As more surgeons, patients, and surgical staff are exposed to an increasing number of orthopaedic procedures that require ionizing radiation to generate images, such as fluoroscopy and CT, it is important to consider the radiation dosage for all individuals and understand the positives and negatives of each treatment. We must consider the overall long-term health impacts of continuous fluoroscopy vs a one-time CT scan. This is of particular importance to the surgeon and surgical staff who may be exposed to cumulative doses during multiple procedures.http://www.sciencedirect.com/science/article/pii/S2352344125000044RadiationFluoroscopyDirect anteriorRoboticComputed tomography
spellingShingle Sean Sequeira, MD
Alan Brett, PhD
Joseph Nessler, MD
Benjamin Frye, MD
Michael A. Mont, MD
Robotic Assistance is Associated With No Intraoperative Fluoroscopy or Radiation Exposure During Direct Anterior Total Hip Arthroplasty
Arthroplasty Today
Radiation
Fluoroscopy
Direct anterior
Robotic
Computed tomography
title Robotic Assistance is Associated With No Intraoperative Fluoroscopy or Radiation Exposure During Direct Anterior Total Hip Arthroplasty
title_full Robotic Assistance is Associated With No Intraoperative Fluoroscopy or Radiation Exposure During Direct Anterior Total Hip Arthroplasty
title_fullStr Robotic Assistance is Associated With No Intraoperative Fluoroscopy or Radiation Exposure During Direct Anterior Total Hip Arthroplasty
title_full_unstemmed Robotic Assistance is Associated With No Intraoperative Fluoroscopy or Radiation Exposure During Direct Anterior Total Hip Arthroplasty
title_short Robotic Assistance is Associated With No Intraoperative Fluoroscopy or Radiation Exposure During Direct Anterior Total Hip Arthroplasty
title_sort robotic assistance is associated with no intraoperative fluoroscopy or radiation exposure during direct anterior total hip arthroplasty
topic Radiation
Fluoroscopy
Direct anterior
Robotic
Computed tomography
url http://www.sciencedirect.com/science/article/pii/S2352344125000044
work_keys_str_mv AT seansequeiramd roboticassistanceisassociatedwithnointraoperativefluoroscopyorradiationexposureduringdirectanteriortotalhiparthroplasty
AT alanbrettphd roboticassistanceisassociatedwithnointraoperativefluoroscopyorradiationexposureduringdirectanteriortotalhiparthroplasty
AT josephnesslermd roboticassistanceisassociatedwithnointraoperativefluoroscopyorradiationexposureduringdirectanteriortotalhiparthroplasty
AT benjaminfryemd roboticassistanceisassociatedwithnointraoperativefluoroscopyorradiationexposureduringdirectanteriortotalhiparthroplasty
AT michaelamontmd roboticassistanceisassociatedwithnointraoperativefluoroscopyorradiationexposureduringdirectanteriortotalhiparthroplasty