Analysis and Verification of Vibration Reduction Solution for TractionConverter Control Cabinet of Locomotive
For the phenomenon of high failure rate of traction converter control cabinet, on-site vibration test and analysis werecarried out, which proved that too large vibration of control cabinet installed base was the main cause of the high failure rate. On thisbasis, the vibration reduction solution of c...
Saved in:
| Main Authors: | , , , , , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Editorial Department of Electric Drive for Locomotives
2016-01-01
|
| Series: | 机车电传动 |
| Subjects: | |
| Online Access: | http://edl.csrzic.com/thesisDetails#10.13890/j.issn.1000-128x.2016.04.101 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849313133270663168 |
|---|---|
| author | WANG Yongsheng DING Jie RONG Zhilin CHENG Zhenglin XU Shaolong GAO Shoucong |
| author_facet | WANG Yongsheng DING Jie RONG Zhilin CHENG Zhenglin XU Shaolong GAO Shoucong |
| author_sort | WANG Yongsheng |
| collection | DOAJ |
| description | For the phenomenon of high failure rate of traction converter control cabinet, on-site vibration test and analysis werecarried out, which proved that too large vibration of control cabinet installed base was the main cause of the high failure rate. On thisbasis, the vibration reduction solution of control cabinet was proposed; simulation analysis and loading test verification was carried out.The simulation results agreed well with the loading test results, and the vibration reduction solution of control cabinet had good vibrationisolation effect with good engineering implementation and high popularization value. |
| format | Article |
| id | doaj-art-a68bbcf851e14659821c86b3ccb408f4 |
| institution | Kabale University |
| issn | 1000-128X |
| language | zho |
| publishDate | 2016-01-01 |
| publisher | Editorial Department of Electric Drive for Locomotives |
| record_format | Article |
| series | 机车电传动 |
| spelling | doaj-art-a68bbcf851e14659821c86b3ccb408f42025-08-20T03:52:51ZzhoEditorial Department of Electric Drive for Locomotives机车电传动1000-128X2016-01-01475020918956Analysis and Verification of Vibration Reduction Solution for TractionConverter Control Cabinet of LocomotiveWANG YongshengDING JieRONG ZhilinCHENG ZhenglinXU ShaolongGAO ShoucongFor the phenomenon of high failure rate of traction converter control cabinet, on-site vibration test and analysis werecarried out, which proved that too large vibration of control cabinet installed base was the main cause of the high failure rate. On thisbasis, the vibration reduction solution of control cabinet was proposed; simulation analysis and loading test verification was carried out.The simulation results agreed well with the loading test results, and the vibration reduction solution of control cabinet had good vibrationisolation effect with good engineering implementation and high popularization value.http://edl.csrzic.com/thesisDetails#10.13890/j.issn.1000-128x.2016.04.101traction convertercontrol cabinetvibration reductionvibration isolationsimulation |
| spellingShingle | WANG Yongsheng DING Jie RONG Zhilin CHENG Zhenglin XU Shaolong GAO Shoucong Analysis and Verification of Vibration Reduction Solution for TractionConverter Control Cabinet of Locomotive 机车电传动 traction converter control cabinet vibration reduction vibration isolation simulation |
| title | Analysis and Verification of Vibration Reduction Solution for TractionConverter Control Cabinet of Locomotive |
| title_full | Analysis and Verification of Vibration Reduction Solution for TractionConverter Control Cabinet of Locomotive |
| title_fullStr | Analysis and Verification of Vibration Reduction Solution for TractionConverter Control Cabinet of Locomotive |
| title_full_unstemmed | Analysis and Verification of Vibration Reduction Solution for TractionConverter Control Cabinet of Locomotive |
| title_short | Analysis and Verification of Vibration Reduction Solution for TractionConverter Control Cabinet of Locomotive |
| title_sort | analysis and verification of vibration reduction solution for tractionconverter control cabinet of locomotive |
| topic | traction converter control cabinet vibration reduction vibration isolation simulation |
| url | http://edl.csrzic.com/thesisDetails#10.13890/j.issn.1000-128x.2016.04.101 |
| work_keys_str_mv | AT wangyongsheng analysisandverificationofvibrationreductionsolutionfortractionconvertercontrolcabinetoflocomotive AT dingjie analysisandverificationofvibrationreductionsolutionfortractionconvertercontrolcabinetoflocomotive AT rongzhilin analysisandverificationofvibrationreductionsolutionfortractionconvertercontrolcabinetoflocomotive AT chengzhenglin analysisandverificationofvibrationreductionsolutionfortractionconvertercontrolcabinetoflocomotive AT xushaolong analysisandverificationofvibrationreductionsolutionfortractionconvertercontrolcabinetoflocomotive AT gaoshoucong analysisandverificationofvibrationreductionsolutionfortractionconvertercontrolcabinetoflocomotive |