Calibration method for the noninvasive current measurement of multicore cables based on two-step estimation

The noninvasive measurement of multicore cables using space magnetic field analysis has characteristics of weak signal intensity, high sensitivity, and vulnerability to environmental or elemental interference. To calibrate the hard iron bias, soft iron bias, and scale factor of magnetoresistance sen...

Full description

Saved in:
Bibliographic Details
Main Authors: SONG Xian, ZHANG Yong-jun, NING Bei-fei, WANG Wei
Format: Article
Language:zho
Published: Science Press 2017-12-01
Series:工程科学学报
Subjects:
Online Access:http://cje.ustb.edu.cn/article/doi/10.13374/j.issn2095-9389.2017.12.017
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850282670433501184
author SONG Xian
ZHANG Yong-jun
NING Bei-fei
WANG Wei
author_facet SONG Xian
ZHANG Yong-jun
NING Bei-fei
WANG Wei
author_sort SONG Xian
collection DOAJ
description The noninvasive measurement of multicore cables using space magnetic field analysis has characteristics of weak signal intensity, high sensitivity, and vulnerability to environmental or elemental interference. To calibrate the hard iron bias, soft iron bias, and scale factor of magnetoresistance sensors based on noninvasive measurements for multicore cables, a two-step estimation-based calibration method was proposed. This method establishes the error-related linear matrix equations through the nonlinear transformation of the sensor output signal and undertakes nonlinear regression calculation after solving the equations, thus implementing dynamic error correction for the measurement of multicore cable current. Results show that this method can simultaneously calibrate linear and partial nonlinear errors of noninvasive current measurement devices for multicore cables.
format Article
id doaj-art-a67eb052a2e54fa1bff710aec2f885f7
institution OA Journals
issn 2095-9389
language zho
publishDate 2017-12-01
publisher Science Press
record_format Article
series 工程科学学报
spelling doaj-art-a67eb052a2e54fa1bff710aec2f885f72025-08-20T01:47:55ZzhoScience Press工程科学学报2095-93892017-12-0139121898190610.13374/j.issn2095-9389.2017.12.017Calibration method for the noninvasive current measurement of multicore cables based on two-step estimationSONG Xian0ZHANG Yong-jun1NING Bei-fei2WANG Wei31) Institute of Engineer Technology, University of Science and Technology Beijing, Beijing 100083, China1) Institute of Engineer Technology, University of Science and Technology Beijing, Beijing 100083, China1) Institute of Engineer Technology, University of Science and Technology Beijing, Beijing 100083, China2) Department of Mechanical Engineering, Tsinghua University, Beijing 100084, ChinaThe noninvasive measurement of multicore cables using space magnetic field analysis has characteristics of weak signal intensity, high sensitivity, and vulnerability to environmental or elemental interference. To calibrate the hard iron bias, soft iron bias, and scale factor of magnetoresistance sensors based on noninvasive measurements for multicore cables, a two-step estimation-based calibration method was proposed. This method establishes the error-related linear matrix equations through the nonlinear transformation of the sensor output signal and undertakes nonlinear regression calculation after solving the equations, thus implementing dynamic error correction for the measurement of multicore cable current. Results show that this method can simultaneously calibrate linear and partial nonlinear errors of noninvasive current measurement devices for multicore cables.http://cje.ustb.edu.cn/article/doi/10.13374/j.issn2095-9389.2017.12.017noninvasive measurementmulticore cabletwo-step methodcalibration
spellingShingle SONG Xian
ZHANG Yong-jun
NING Bei-fei
WANG Wei
Calibration method for the noninvasive current measurement of multicore cables based on two-step estimation
工程科学学报
noninvasive measurement
multicore cable
two-step method
calibration
title Calibration method for the noninvasive current measurement of multicore cables based on two-step estimation
title_full Calibration method for the noninvasive current measurement of multicore cables based on two-step estimation
title_fullStr Calibration method for the noninvasive current measurement of multicore cables based on two-step estimation
title_full_unstemmed Calibration method for the noninvasive current measurement of multicore cables based on two-step estimation
title_short Calibration method for the noninvasive current measurement of multicore cables based on two-step estimation
title_sort calibration method for the noninvasive current measurement of multicore cables based on two step estimation
topic noninvasive measurement
multicore cable
two-step method
calibration
url http://cje.ustb.edu.cn/article/doi/10.13374/j.issn2095-9389.2017.12.017
work_keys_str_mv AT songxian calibrationmethodforthenoninvasivecurrentmeasurementofmulticorecablesbasedontwostepestimation
AT zhangyongjun calibrationmethodforthenoninvasivecurrentmeasurementofmulticorecablesbasedontwostepestimation
AT ningbeifei calibrationmethodforthenoninvasivecurrentmeasurementofmulticorecablesbasedontwostepestimation
AT wangwei calibrationmethodforthenoninvasivecurrentmeasurementofmulticorecablesbasedontwostepestimation