Accuracy of magnetic resonance imaging texture analysis in differentiating low-grade from high-grade gliomas: systematic review and meta-analysis

Objectives Texture analysis (TA) is a method used for quantifying the spatial distributions of intensities in images using scanning software. MRI TA could be applied to grade gliomas. This meta-analysis was performed for assessing the accuracy of MRI TA in differentiating low-grade gliomas from high...

Full description

Saved in:
Bibliographic Details
Main Authors: Qiangping Wang, Deqiang Lei, Ye Yuan, Hongyang Zhao
Format: Article
Language:English
Published: BMJ Publishing Group 2019-09-01
Series:BMJ Open
Online Access:https://bmjopen.bmj.com/content/9/9/e027144.full
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850181588725268480
author Qiangping Wang
Deqiang Lei
Ye Yuan
Hongyang Zhao
author_facet Qiangping Wang
Deqiang Lei
Ye Yuan
Hongyang Zhao
author_sort Qiangping Wang
collection DOAJ
description Objectives Texture analysis (TA) is a method used for quantifying the spatial distributions of intensities in images using scanning software. MRI TA could be applied to grade gliomas. This meta-analysis was performed for assessing the accuracy of MRI TA in differentiating low-grade gliomas from high-grade ones.Methods PubMed, Cochrane Library, Science Direct and Embase were searched for identifying suitable studies from their inception to 1 September 2018. The quality of the studies was evaluated on the basis of the Quality Assessment of Diagnostic Accuracy Studies guidelines. We estimated the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnostic OR (DOR) using the summary receiver operating characteristic (SROC) for identifying the accuracy of MRI TA in grading gliomas. Fagan nomogram was applied for assessing the clinical utility of TA.Results Six studies including 440 patients were included and analysed. The pooled sensitivity, specificity, PLR, NLR and DOR with 95% CIs were 0.93 (95% CI 0.88 to 0.96), 0.86 (95% CI 0.81 to 0.89), 6.4 (95% CI 4.8 to 8.6), 0.08 (95% CI 0.05 to 0.15) and 78 (95% CI 39 to 156), respectively. The SROC curve showed an area under the curve of 0.96 (95% CI 0.93 to 0.97). Deeks test confirmed no significant publication bias in all studies. Fagan nomogram revealed that the post-test probability increased by 43% in patients with positive pre-test.Conclusions The findings of this meta-analysis suggested that MRI TA has high accuracy in differentiating low-grade gliomas from high-grade ones. A standardised methodology is warranted to guide the use of this technique for clinical decision-making.
format Article
id doaj-art-a5c9acf1cc08424f893b7f968d8ee471
institution OA Journals
issn 2044-6055
language English
publishDate 2019-09-01
publisher BMJ Publishing Group
record_format Article
series BMJ Open
spelling doaj-art-a5c9acf1cc08424f893b7f968d8ee4712025-08-20T02:17:52ZengBMJ Publishing GroupBMJ Open2044-60552019-09-019910.1136/bmjopen-2018-027144Accuracy of magnetic resonance imaging texture analysis in differentiating low-grade from high-grade gliomas: systematic review and meta-analysisQiangping Wang0Deqiang Lei1Ye Yuan2Hongyang Zhao3Department of Neurosurgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, ChinaDepartment of Neurosurgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, ChinaDepartment of Intelligent Medical Engineering, School of Biomedical Engineering, Anhui Medical University, Hefei, Anhui, ChinaDepartment of Neurosurgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, ChinaObjectives Texture analysis (TA) is a method used for quantifying the spatial distributions of intensities in images using scanning software. MRI TA could be applied to grade gliomas. This meta-analysis was performed for assessing the accuracy of MRI TA in differentiating low-grade gliomas from high-grade ones.Methods PubMed, Cochrane Library, Science Direct and Embase were searched for identifying suitable studies from their inception to 1 September 2018. The quality of the studies was evaluated on the basis of the Quality Assessment of Diagnostic Accuracy Studies guidelines. We estimated the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnostic OR (DOR) using the summary receiver operating characteristic (SROC) for identifying the accuracy of MRI TA in grading gliomas. Fagan nomogram was applied for assessing the clinical utility of TA.Results Six studies including 440 patients were included and analysed. The pooled sensitivity, specificity, PLR, NLR and DOR with 95% CIs were 0.93 (95% CI 0.88 to 0.96), 0.86 (95% CI 0.81 to 0.89), 6.4 (95% CI 4.8 to 8.6), 0.08 (95% CI 0.05 to 0.15) and 78 (95% CI 39 to 156), respectively. The SROC curve showed an area under the curve of 0.96 (95% CI 0.93 to 0.97). Deeks test confirmed no significant publication bias in all studies. Fagan nomogram revealed that the post-test probability increased by 43% in patients with positive pre-test.Conclusions The findings of this meta-analysis suggested that MRI TA has high accuracy in differentiating low-grade gliomas from high-grade ones. A standardised methodology is warranted to guide the use of this technique for clinical decision-making.https://bmjopen.bmj.com/content/9/9/e027144.full
spellingShingle Qiangping Wang
Deqiang Lei
Ye Yuan
Hongyang Zhao
Accuracy of magnetic resonance imaging texture analysis in differentiating low-grade from high-grade gliomas: systematic review and meta-analysis
BMJ Open
title Accuracy of magnetic resonance imaging texture analysis in differentiating low-grade from high-grade gliomas: systematic review and meta-analysis
title_full Accuracy of magnetic resonance imaging texture analysis in differentiating low-grade from high-grade gliomas: systematic review and meta-analysis
title_fullStr Accuracy of magnetic resonance imaging texture analysis in differentiating low-grade from high-grade gliomas: systematic review and meta-analysis
title_full_unstemmed Accuracy of magnetic resonance imaging texture analysis in differentiating low-grade from high-grade gliomas: systematic review and meta-analysis
title_short Accuracy of magnetic resonance imaging texture analysis in differentiating low-grade from high-grade gliomas: systematic review and meta-analysis
title_sort accuracy of magnetic resonance imaging texture analysis in differentiating low grade from high grade gliomas systematic review and meta analysis
url https://bmjopen.bmj.com/content/9/9/e027144.full
work_keys_str_mv AT qiangpingwang accuracyofmagneticresonanceimagingtextureanalysisindifferentiatinglowgradefromhighgradegliomassystematicreviewandmetaanalysis
AT deqianglei accuracyofmagneticresonanceimagingtextureanalysisindifferentiatinglowgradefromhighgradegliomassystematicreviewandmetaanalysis
AT yeyuan accuracyofmagneticresonanceimagingtextureanalysisindifferentiatinglowgradefromhighgradegliomassystematicreviewandmetaanalysis
AT hongyangzhao accuracyofmagneticresonanceimagingtextureanalysisindifferentiatinglowgradefromhighgradegliomassystematicreviewandmetaanalysis