Design considerations for rectangular bolted full face flanged joints for surface condensers

Rectangular bolted full face flanged joints are widely used in surface condensers within the power generation industry including the nuclear one. In order to design these components, it is necessary to analyze the flanged joint from the point of view of structural strength and tightness. This work p...

Full description

Saved in:
Bibliographic Details
Main Authors: Augusto Soave, Miguel Mattar Neto
Format: Article
Language:English
Published: Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR) 2022-10-01
Series:Brazilian Journal of Radiation Sciences
Subjects:
Online Access:https://bjrs.org.br/revista/index.php/REVISTA/article/view/1989
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849430836377550848
author Augusto Soave
Miguel Mattar Neto
author_facet Augusto Soave
Miguel Mattar Neto
author_sort Augusto Soave
collection DOAJ
description Rectangular bolted full face flanged joints are widely used in surface condensers within the power generation industry including the nuclear one. In order to design these components, it is necessary to analyze the flanged joint from the point of view of structural strength and tightness. This work presents an analytical procedure applied to a rectangular bolted flange to determine the thickness of the flange, the bolt stresses and tightness conditions. First, the proposed analytical procedure is validated by comparing results from finite element analysis (FEA) using non-linear approach considering the behavior of the gasket and contacts. In addition, the results of proposed procedure applied to the design of a rectangular flanged joint of a steam surface condenser were compared for two different gaskets: compressed non-asbestos fiber gasket and NBR elastomer gasket. The results show a better performance of the NBR elastomer gasket in comparison with compressed fiber gasket: better sealing conditions, reduction of thicknesses of flange and reduction of bolt stresses. It is important to highlight there are practically no references of procedures for design non-circular full face flanged joints.
format Article
id doaj-art-a5b9ccd59f3441fcb3cdd840090a423d
institution Kabale University
issn 2319-0612
language English
publishDate 2022-10-01
publisher Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)
record_format Article
series Brazilian Journal of Radiation Sciences
spelling doaj-art-a5b9ccd59f3441fcb3cdd840090a423d2025-08-20T03:27:51ZengBrazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)Brazilian Journal of Radiation Sciences2319-06122022-10-01103A (Suppl.)10.15392/2319-0612.2022.19891607Design considerations for rectangular bolted full face flanged joints for surface condensersAugusto Soave0Miguel Mattar Neto1IPEN - Instituto de Pesquisas Energéticas e NuclearesInstituto de Pesquisas Energéticas e Nucleares IPEN-CNENRectangular bolted full face flanged joints are widely used in surface condensers within the power generation industry including the nuclear one. In order to design these components, it is necessary to analyze the flanged joint from the point of view of structural strength and tightness. This work presents an analytical procedure applied to a rectangular bolted flange to determine the thickness of the flange, the bolt stresses and tightness conditions. First, the proposed analytical procedure is validated by comparing results from finite element analysis (FEA) using non-linear approach considering the behavior of the gasket and contacts. In addition, the results of proposed procedure applied to the design of a rectangular flanged joint of a steam surface condenser were compared for two different gaskets: compressed non-asbestos fiber gasket and NBR elastomer gasket. The results show a better performance of the NBR elastomer gasket in comparison with compressed fiber gasket: better sealing conditions, reduction of thicknesses of flange and reduction of bolt stresses. It is important to highlight there are practically no references of procedures for design non-circular full face flanged joints.https://bjrs.org.br/revista/index.php/REVISTA/article/view/1989bolted joint, full face, rectangular flange, surface condenser
spellingShingle Augusto Soave
Miguel Mattar Neto
Design considerations for rectangular bolted full face flanged joints for surface condensers
Brazilian Journal of Radiation Sciences
bolted joint, full face, rectangular flange, surface condenser
title Design considerations for rectangular bolted full face flanged joints for surface condensers
title_full Design considerations for rectangular bolted full face flanged joints for surface condensers
title_fullStr Design considerations for rectangular bolted full face flanged joints for surface condensers
title_full_unstemmed Design considerations for rectangular bolted full face flanged joints for surface condensers
title_short Design considerations for rectangular bolted full face flanged joints for surface condensers
title_sort design considerations for rectangular bolted full face flanged joints for surface condensers
topic bolted joint, full face, rectangular flange, surface condenser
url https://bjrs.org.br/revista/index.php/REVISTA/article/view/1989
work_keys_str_mv AT augustosoave designconsiderationsforrectangularboltedfullfaceflangedjointsforsurfacecondensers
AT miguelmattarneto designconsiderationsforrectangularboltedfullfaceflangedjointsforsurfacecondensers