Why Current Doppler Ultrasound Methodology Is Inaccurate in Assessing Cerebral Venous Return: The Alternative of the Ultrasonic Jugular Venous Pulse

Assessment of cerebral venous return is growing interest for potential application in clinical practice. Doppler ultrasound (DUS) was used as a screening tool. However, three meta-analyses of qualitative DUS protocol demonstrate a big heterogeneity among studies. In an attempt to improve accuracy, s...

Full description

Saved in:
Bibliographic Details
Main Author: Paolo Zamboni
Format: Article
Language:English
Published: Wiley 2016-01-01
Series:Behavioural Neurology
Online Access:http://dx.doi.org/10.1155/2016/7082856
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832553280543129600
author Paolo Zamboni
author_facet Paolo Zamboni
author_sort Paolo Zamboni
collection DOAJ
description Assessment of cerebral venous return is growing interest for potential application in clinical practice. Doppler ultrasound (DUS) was used as a screening tool. However, three meta-analyses of qualitative DUS protocol demonstrate a big heterogeneity among studies. In an attempt to improve accuracy, several authors alternatively measured the flow rate, based on the product of the time average velocity with the cross-sectional area (CSA). However, also the quantification protocols lacked of the necessary accuracy. The reasons are as follows: (a) automatic measurement of the CSA assimilates the jugular to a circle, while it is elliptical; (b) the use of just a single CSA value in a pulsatile vessel is inaccurate; (c) time average velocity assessment can be applied only in laminar flow. Finally, the tutorial describes alternative ultrasound calculation of flow based on the Womersley method, which takes into account the variation of the jugular CSA overtime. In the near future, it will be possible to synchronize the electrocardiogram with the brain inflow (carotid distension wave) and with the outflow (jugular venous pulse) in order to nicely have a noninvasive ultrasound picture of the brain-heart axis. US jugular venous pulse may have potential use in neurovascular, neurocognitive, neurosensorial, and neurodegenerative disorders.
format Article
id doaj-art-a4fad6e86a6c44f9be495e6d14bb5a9d
institution Kabale University
issn 0953-4180
1875-8584
language English
publishDate 2016-01-01
publisher Wiley
record_format Article
series Behavioural Neurology
spelling doaj-art-a4fad6e86a6c44f9be495e6d14bb5a9d2025-02-03T05:54:24ZengWileyBehavioural Neurology0953-41801875-85842016-01-01201610.1155/2016/70828567082856Why Current Doppler Ultrasound Methodology Is Inaccurate in Assessing Cerebral Venous Return: The Alternative of the Ultrasonic Jugular Venous PulsePaolo Zamboni0Vascular Diseases Center, University of Ferrara, Via Aldo Moro 8, Cona, 44124 Ferrara, ItalyAssessment of cerebral venous return is growing interest for potential application in clinical practice. Doppler ultrasound (DUS) was used as a screening tool. However, three meta-analyses of qualitative DUS protocol demonstrate a big heterogeneity among studies. In an attempt to improve accuracy, several authors alternatively measured the flow rate, based on the product of the time average velocity with the cross-sectional area (CSA). However, also the quantification protocols lacked of the necessary accuracy. The reasons are as follows: (a) automatic measurement of the CSA assimilates the jugular to a circle, while it is elliptical; (b) the use of just a single CSA value in a pulsatile vessel is inaccurate; (c) time average velocity assessment can be applied only in laminar flow. Finally, the tutorial describes alternative ultrasound calculation of flow based on the Womersley method, which takes into account the variation of the jugular CSA overtime. In the near future, it will be possible to synchronize the electrocardiogram with the brain inflow (carotid distension wave) and with the outflow (jugular venous pulse) in order to nicely have a noninvasive ultrasound picture of the brain-heart axis. US jugular venous pulse may have potential use in neurovascular, neurocognitive, neurosensorial, and neurodegenerative disorders.http://dx.doi.org/10.1155/2016/7082856
spellingShingle Paolo Zamboni
Why Current Doppler Ultrasound Methodology Is Inaccurate in Assessing Cerebral Venous Return: The Alternative of the Ultrasonic Jugular Venous Pulse
Behavioural Neurology
title Why Current Doppler Ultrasound Methodology Is Inaccurate in Assessing Cerebral Venous Return: The Alternative of the Ultrasonic Jugular Venous Pulse
title_full Why Current Doppler Ultrasound Methodology Is Inaccurate in Assessing Cerebral Venous Return: The Alternative of the Ultrasonic Jugular Venous Pulse
title_fullStr Why Current Doppler Ultrasound Methodology Is Inaccurate in Assessing Cerebral Venous Return: The Alternative of the Ultrasonic Jugular Venous Pulse
title_full_unstemmed Why Current Doppler Ultrasound Methodology Is Inaccurate in Assessing Cerebral Venous Return: The Alternative of the Ultrasonic Jugular Venous Pulse
title_short Why Current Doppler Ultrasound Methodology Is Inaccurate in Assessing Cerebral Venous Return: The Alternative of the Ultrasonic Jugular Venous Pulse
title_sort why current doppler ultrasound methodology is inaccurate in assessing cerebral venous return the alternative of the ultrasonic jugular venous pulse
url http://dx.doi.org/10.1155/2016/7082856
work_keys_str_mv AT paolozamboni whycurrentdopplerultrasoundmethodologyisinaccurateinassessingcerebralvenousreturnthealternativeoftheultrasonicjugularvenouspulse